語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
FindBook
Google Book
Amazon
博客來
Physical Limits to Cellular Sensing of the Environment.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Physical Limits to Cellular Sensing of the Environment./
作者:
Vennettilli, Michael.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2021,
面頁冊數:
144 p.
附註:
Source: Dissertations Abstracts International, Volume: 83-07, Section: B.
Contained By:
Dissertations Abstracts International83-07B.
標題:
Cancer. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28926160
ISBN:
9798762119481
Physical Limits to Cellular Sensing of the Environment.
Vennettilli, Michael.
Physical Limits to Cellular Sensing of the Environment.
- Ann Arbor : ProQuest Dissertations & Theses, 2021 - 144 p.
Source: Dissertations Abstracts International, Volume: 83-07, Section: B.
Thesis (Ph.D.)--University of Pittsburgh, 2021.
This item must not be sold to any third party vendors.
Cells must accurately sense various aspects of their environment for survival. In 1977, Berg and Purcell initiated a line of work placing physical limits on cells. The work herein is a continuation of this tradition. In our first project, we studied the effect of critical biochemical feedback on cell sensing. Using a concrete model, we weighed the trade-offs between high susceptibility, long-range correlations and critical slowing down. We found that the critical system could have high steady state mutual information between a ligand and an internal readout molecule if the ligand dynamics are sufficiently slower than the intracellular dynamics. However, the information rate is always minimized at the critical point due to critical slowing down. Our second and third projects involved deriving lower bounds on signal-to-noise ratios for environmental variables, much like the initial work of Berg and Purcell. The novelty is that the sensed quantities are fluid flow direction and temperature. These extend the range of their work, as these are non-chemical cues, however, they are sensed using molecules. Our work on flow sensing was motivated by studies on metastatic cancer cells that showed they could detect the direction of fluid flow. They do so by secreting molecules that are pushed by the flow and return to the surface anisotropically. We compared two different strategies for signal transduction: endocytosis and reversible binding. We found that reversible binding admits a lower relative error than endocytosis. The endocytosis model has an optimal absorption rate. We use experimental data to argue that the endocytosis rate is far from the optimum, supporting the possibility that receptor binding transduces the information. In our third project, we started by computing the relative error in temperature sensing arising from its own fluctuations. We found that it was too low to be limiting. Temperature sensing is indirect, it is transduced from molecular conformations, changing reaction rates, or various mechanical properties. Turning to a biochemical model based on the canonical protein thermometer TlpA, we found that the error arising from the biochemical reactions dominated the system. We discuss the connection to existing experimental data.
ISBN: 9798762119481Subjects--Topical Terms:
634186
Cancer.
Physical Limits to Cellular Sensing of the Environment.
LDR
:03376nmm a2200337 4500
001
2344950
005
20220531062222.5
008
241004s2021 ||||||||||||||||| ||eng d
020
$a
9798762119481
035
$a
(MiAaPQ)AAI28926160
035
$a
(MiAaPQ)Pittsburgh41568
035
$a
AAI28926160
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Vennettilli, Michael.
$3
3683799
245
1 0
$a
Physical Limits to Cellular Sensing of the Environment.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2021
300
$a
144 p.
500
$a
Source: Dissertations Abstracts International, Volume: 83-07, Section: B.
500
$a
Advisor: Xing, Jianhua;Wu, Xiao-Lun;Salman, Hanna;Mugler, Andrew;Coalson, Rob D. .
502
$a
Thesis (Ph.D.)--University of Pittsburgh, 2021.
506
$a
This item must not be sold to any third party vendors.
520
$a
Cells must accurately sense various aspects of their environment for survival. In 1977, Berg and Purcell initiated a line of work placing physical limits on cells. The work herein is a continuation of this tradition. In our first project, we studied the effect of critical biochemical feedback on cell sensing. Using a concrete model, we weighed the trade-offs between high susceptibility, long-range correlations and critical slowing down. We found that the critical system could have high steady state mutual information between a ligand and an internal readout molecule if the ligand dynamics are sufficiently slower than the intracellular dynamics. However, the information rate is always minimized at the critical point due to critical slowing down. Our second and third projects involved deriving lower bounds on signal-to-noise ratios for environmental variables, much like the initial work of Berg and Purcell. The novelty is that the sensed quantities are fluid flow direction and temperature. These extend the range of their work, as these are non-chemical cues, however, they are sensed using molecules. Our work on flow sensing was motivated by studies on metastatic cancer cells that showed they could detect the direction of fluid flow. They do so by secreting molecules that are pushed by the flow and return to the surface anisotropically. We compared two different strategies for signal transduction: endocytosis and reversible binding. We found that reversible binding admits a lower relative error than endocytosis. The endocytosis model has an optimal absorption rate. We use experimental data to argue that the endocytosis rate is far from the optimum, supporting the possibility that receptor binding transduces the information. In our third project, we started by computing the relative error in temperature sensing arising from its own fluctuations. We found that it was too low to be limiting. Temperature sensing is indirect, it is transduced from molecular conformations, changing reaction rates, or various mechanical properties. Turning to a biochemical model based on the canonical protein thermometer TlpA, we found that the error arising from the biochemical reactions dominated the system. We discuss the connection to existing experimental data.
590
$a
School code: 0178.
650
4
$a
Cancer.
$3
634186
650
4
$a
Gene expression.
$3
643979
650
4
$a
Binding sites.
$3
3560349
650
4
$a
Ligands.
$3
686413
650
4
$a
Cellular biology.
$3
3172791
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Molecular biology.
$3
517296
650
4
$a
Biochemistry.
$3
518028
690
$a
0379
690
$a
0541
690
$a
0487
690
$a
0307
710
2
$a
University of Pittsburgh.
$3
958527
773
0
$t
Dissertations Abstracts International
$g
83-07B.
790
$a
0178
791
$a
Ph.D.
792
$a
2021
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28926160
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9467388
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入