Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
A Scalable, Point-of-Care, Microflui...
~
Rossi, Jason M.
Linked to FindBook
Google Book
Amazon
博客來
A Scalable, Point-of-Care, Microfluidic Approach for Assessing Thrombosis and Hemostasis.
Record Type:
Electronic resources : Monograph/item
Title/Author:
A Scalable, Point-of-Care, Microfluidic Approach for Assessing Thrombosis and Hemostasis./
Author:
Rossi, Jason M.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2021,
Description:
156 p.
Notes:
Source: Dissertations Abstracts International, Volume: 82-12, Section: B.
Contained By:
Dissertations Abstracts International82-12B.
Subject:
Bioengineering. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28419189
ISBN:
9798738649943
A Scalable, Point-of-Care, Microfluidic Approach for Assessing Thrombosis and Hemostasis.
Rossi, Jason M.
A Scalable, Point-of-Care, Microfluidic Approach for Assessing Thrombosis and Hemostasis.
- Ann Arbor : ProQuest Dissertations & Theses, 2021 - 156 p.
Source: Dissertations Abstracts International, Volume: 82-12, Section: B.
Thesis (Ph.D.)--University of Pennsylvania, 2021.
This item must not be sold to any third party vendors.
Coagulation testing is an important diagnostic tool for the detection of excessive bleeding risk or obstructive clot formation (thrombosis), using blood samples from patients. Microfluidic flow devices have been well established to provide insights on the impacts of shear rate, drug action, and disease state on coagulation and platelet biology. The bulk of the microfluidic devices and assays used in the past have relied upon manual assembly using poly(dimethylsiloxane) (PDMS), a material and construction method not well suited to use in a clinical setting. This thesis describes the design and testing of a single-use, storage stable evolution of previous PDMS microfluidic designs, manufactured via injection molding and pressure-sensitive adhesive bonding. Using this device, we demonstrate the ability to make internally consistent and repeatable measurements of platelet and fibrin fluorescence intensity in clots forming under venous shear rate, using a bench-top LED microscope, and physiologically representative constant-pressure driven flow. We also demonstrate the ability to detect a strong, dose-dependent reduction in the fibrin fluorescence intensity signal in response to in vitro spiking of direct oral anticoagulants (DOACs). Further, we showed the ability to reverse this inhibition, through the addition of small quantities of drug reversal agents. In a separate study, the presence of DOACs in the blood of patients on the medications was clearly detected. Utilizing the previously obtained data from in vitro spiking, the relative response of DOAC patient blood with and without reversal agent was used to generate a quantitative prediction for the current concentration of drug in their system. The field of coagulation testing has lacked a definitive candidate for a fast, reliable means of accurately assessing patient anticoagulation status. Taken together, the ability to both identify the presence and predict the quantity of DOAC in a patient's blood using a single-use microfluidic chip approach, as described in this thesis, represents a potential promising new direction for coagulation testing at the bed-side.
ISBN: 9798738649943Subjects--Topical Terms:
657580
Bioengineering.
Subjects--Index Terms:
Flow simulations
A Scalable, Point-of-Care, Microfluidic Approach for Assessing Thrombosis and Hemostasis.
LDR
:03416nmm a2200397 4500
001
2282940
005
20211022115804.5
008
220723s2021 ||||||||||||||||| ||eng d
020
$a
9798738649943
035
$a
(MiAaPQ)AAI28419189
035
$a
AAI28419189
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Rossi, Jason M.
$3
3561827
245
1 0
$a
A Scalable, Point-of-Care, Microfluidic Approach for Assessing Thrombosis and Hemostasis.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2021
300
$a
156 p.
500
$a
Source: Dissertations Abstracts International, Volume: 82-12, Section: B.
500
$a
Advisor: Diamond, Scott L.
502
$a
Thesis (Ph.D.)--University of Pennsylvania, 2021.
506
$a
This item must not be sold to any third party vendors.
506
$a
This item must not be sold to any third party vendors.
520
$a
Coagulation testing is an important diagnostic tool for the detection of excessive bleeding risk or obstructive clot formation (thrombosis), using blood samples from patients. Microfluidic flow devices have been well established to provide insights on the impacts of shear rate, drug action, and disease state on coagulation and platelet biology. The bulk of the microfluidic devices and assays used in the past have relied upon manual assembly using poly(dimethylsiloxane) (PDMS), a material and construction method not well suited to use in a clinical setting. This thesis describes the design and testing of a single-use, storage stable evolution of previous PDMS microfluidic designs, manufactured via injection molding and pressure-sensitive adhesive bonding. Using this device, we demonstrate the ability to make internally consistent and repeatable measurements of platelet and fibrin fluorescence intensity in clots forming under venous shear rate, using a bench-top LED microscope, and physiologically representative constant-pressure driven flow. We also demonstrate the ability to detect a strong, dose-dependent reduction in the fibrin fluorescence intensity signal in response to in vitro spiking of direct oral anticoagulants (DOACs). Further, we showed the ability to reverse this inhibition, through the addition of small quantities of drug reversal agents. In a separate study, the presence of DOACs in the blood of patients on the medications was clearly detected. Utilizing the previously obtained data from in vitro spiking, the relative response of DOAC patient blood with and without reversal agent was used to generate a quantitative prediction for the current concentration of drug in their system. The field of coagulation testing has lacked a definitive candidate for a fast, reliable means of accurately assessing patient anticoagulation status. Taken together, the ability to both identify the presence and predict the quantity of DOAC in a patient's blood using a single-use microfluidic chip approach, as described in this thesis, represents a potential promising new direction for coagulation testing at the bed-side.
590
$a
School code: 0175.
650
4
$a
Bioengineering.
$3
657580
650
4
$a
Biochemistry.
$3
518028
650
4
$a
Health care management.
$3
2122906
653
$a
Flow simulations
653
$a
Haemodynamics
653
$a
Immunofluorescence
653
$a
Microfluidics
653
$a
Proteins
653
$a
Thrombosis
690
$a
0202
690
$a
0487
690
$a
0769
710
2
$a
University of Pennsylvania.
$b
Chemical and Biomolecular Engineering.
$3
2101616
773
0
$t
Dissertations Abstracts International
$g
82-12B.
790
$a
0175
791
$a
Ph.D.
792
$a
2021
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28419189
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9434673
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login