語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
MRI Excitation Pulse Design and Imag...
~
Luo, Tianrui.
FindBook
Google Book
Amazon
博客來
MRI Excitation Pulse Design and Image Reconstruction for Accelerated Neuroimaging.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
MRI Excitation Pulse Design and Image Reconstruction for Accelerated Neuroimaging./
作者:
Luo, Tianrui.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2021,
面頁冊數:
123 p.
附註:
Source: Dissertations Abstracts International, Volume: 83-01, Section: B.
Contained By:
Dissertations Abstracts International83-01B.
標題:
Biomedical engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28667026
ISBN:
9798516089275
MRI Excitation Pulse Design and Image Reconstruction for Accelerated Neuroimaging.
Luo, Tianrui.
MRI Excitation Pulse Design and Image Reconstruction for Accelerated Neuroimaging.
- Ann Arbor : ProQuest Dissertations & Theses, 2021 - 123 p.
Source: Dissertations Abstracts International, Volume: 83-01, Section: B.
Thesis (Ph.D.)--University of Michigan, 2021.
This item must not be sold to any third party vendors.
Excitation pulse design and image reconstruction are two important topics in MR research for enabling faster imaging. On the pulse design side, selective excitations that confine signals to be within a small region-of-interest (ROI) instead of the full imaging field-of-view (FOV) can be used to reduce sampling density in the k-space, which is a direct outcome of the change in the underlying Nyquist sampling rate. On the reconstruction side, besides improving imaging algorithms' ability to restore images from less data, another objective is to reduce the reconstruction time, particularly for dynamic imaging applications. This dissertation focuses on these two perspectives: Chapter II is devoted to the excitation pulse design. Specifically, we exploit auto-differentiation frameworks that automatically apply the chain rule on complicated computations. We derived and developed a computationally efficient Bloch-simulator and its explicit Bloch simulation Jacobian operations using such frameworks. This simulator can yield numerical derivatives with respect to pulse RF and gradient waveforms given arbitrary sub-differentiable excitation objective functions. The method does not rely on the small-tip approximation, and is accurate as long as the Bloch simulation can correctly model the spin movements due to the excitation pulses. In particular, we successfully applied this pulse design approach for jointly designing RF and gradient waveforms for 3D spatially tailored large-tip excitation objectives. The auto-differentiable pulse design method can yield superior 3D spatially tailored excitation profiles that are useful for inner volume (IV) imaging, where one attempts to image a volumetric ROI at high spatiotemporal resolution without aliasing from signals outside the IV (i.e., outer volume). In Chapter III, we propose and develop a novel steady-state IV imaging strategy which suppresses aliasing by saturating the outer volume (OV) magnetizations via a 3D tailored OV excitation pulse that is followed by a signal crusher gradient. This saturation based strategy can substantially suppress the unwanted aliasing for common steady-state imaging sequences. By eliminating the outer volume signals, one can configure acquisitions for a reduced FOV to shorten the scanning time and increase spatiotemporal resolution for applications such as dynamic imaging. In dynamic imaging (e.g., fMRI), where a time series is to be reconstructed, non-iterative reconstruction algorithms may offer savings in overall reconstruction time. Chapter IV focuses on non-iterative image reconstruction, specifically, extending the GRAPPA algorithm to general non-Cartesian acquisitions. We analyzed the formalism of conventional GRAPPA reconstruction coefficients, generalized it to non-Cartesian scenarios by using properties of the Fourier transform, and obtained an efficient non-Cartesian GRAPPA algorithm. The algorithm attains reconstruction quality that can rival classical iterative imaging methods such as conjugate gradient SENSE and SPIRiT. In summary, this dissertation has proposed and developed multiple methods for accelerating MR imaging, from pulse design to reconstruction. While devoted to neuroimaging, the proposed methods are general and should also be useful for other applications.
ISBN: 9798516089275Subjects--Topical Terms:
535387
Biomedical engineering.
Subjects--Index Terms:
Magnetic resonance imaging
MRI Excitation Pulse Design and Image Reconstruction for Accelerated Neuroimaging.
LDR
:04479nmm a2200349 4500
001
2281967
005
20210927083442.5
008
220723s2021 ||||||||||||||||| ||eng d
020
$a
9798516089275
035
$a
(MiAaPQ)AAI28667026
035
$a
(MiAaPQ)umichrackham003602
035
$a
AAI28667026
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Luo, Tianrui.
$3
3560681
245
1 0
$a
MRI Excitation Pulse Design and Image Reconstruction for Accelerated Neuroimaging.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2021
300
$a
123 p.
500
$a
Source: Dissertations Abstracts International, Volume: 83-01, Section: B.
502
$a
Thesis (Ph.D.)--University of Michigan, 2021.
506
$a
This item must not be sold to any third party vendors.
506
$a
This item must not be added to any third party search indexes.
520
$a
Excitation pulse design and image reconstruction are two important topics in MR research for enabling faster imaging. On the pulse design side, selective excitations that confine signals to be within a small region-of-interest (ROI) instead of the full imaging field-of-view (FOV) can be used to reduce sampling density in the k-space, which is a direct outcome of the change in the underlying Nyquist sampling rate. On the reconstruction side, besides improving imaging algorithms' ability to restore images from less data, another objective is to reduce the reconstruction time, particularly for dynamic imaging applications. This dissertation focuses on these two perspectives: Chapter II is devoted to the excitation pulse design. Specifically, we exploit auto-differentiation frameworks that automatically apply the chain rule on complicated computations. We derived and developed a computationally efficient Bloch-simulator and its explicit Bloch simulation Jacobian operations using such frameworks. This simulator can yield numerical derivatives with respect to pulse RF and gradient waveforms given arbitrary sub-differentiable excitation objective functions. The method does not rely on the small-tip approximation, and is accurate as long as the Bloch simulation can correctly model the spin movements due to the excitation pulses. In particular, we successfully applied this pulse design approach for jointly designing RF and gradient waveforms for 3D spatially tailored large-tip excitation objectives. The auto-differentiable pulse design method can yield superior 3D spatially tailored excitation profiles that are useful for inner volume (IV) imaging, where one attempts to image a volumetric ROI at high spatiotemporal resolution without aliasing from signals outside the IV (i.e., outer volume). In Chapter III, we propose and develop a novel steady-state IV imaging strategy which suppresses aliasing by saturating the outer volume (OV) magnetizations via a 3D tailored OV excitation pulse that is followed by a signal crusher gradient. This saturation based strategy can substantially suppress the unwanted aliasing for common steady-state imaging sequences. By eliminating the outer volume signals, one can configure acquisitions for a reduced FOV to shorten the scanning time and increase spatiotemporal resolution for applications such as dynamic imaging. In dynamic imaging (e.g., fMRI), where a time series is to be reconstructed, non-iterative reconstruction algorithms may offer savings in overall reconstruction time. Chapter IV focuses on non-iterative image reconstruction, specifically, extending the GRAPPA algorithm to general non-Cartesian acquisitions. We analyzed the formalism of conventional GRAPPA reconstruction coefficients, generalized it to non-Cartesian scenarios by using properties of the Fourier transform, and obtained an efficient non-Cartesian GRAPPA algorithm. The algorithm attains reconstruction quality that can rival classical iterative imaging methods such as conjugate gradient SENSE and SPIRiT. In summary, this dissertation has proposed and developed multiple methods for accelerating MR imaging, from pulse design to reconstruction. While devoted to neuroimaging, the proposed methods are general and should also be useful for other applications.
590
$a
School code: 0127.
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Medical imaging.
$3
3172799
653
$a
Magnetic resonance imaging
653
$a
Pulse Design
653
$a
Image Reconstruction
690
$a
0541
690
$a
0574
710
2
$a
University of Michigan.
$b
Biomedical Engineering.
$3
2096486
773
0
$t
Dissertations Abstracts International
$g
83-01B.
790
$a
0127
791
$a
Ph.D.
792
$a
2021
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28667026
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9433700
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入