Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Thermo-Mechanical Modeling and the A...
~
Hunt, Robert.
Linked to FindBook
Google Book
Amazon
博客來
Thermo-Mechanical Modeling and the Application of Coiled Polymer Actuators in Soft Robotics and Biomimetics.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Thermo-Mechanical Modeling and the Application of Coiled Polymer Actuators in Soft Robotics and Biomimetics./
Author:
Hunt, Robert.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2020,
Description:
182 p.
Notes:
Source: Dissertations Abstracts International, Volume: 82-06, Section: B.
Contained By:
Dissertations Abstracts International82-06B.
Subject:
Mechanical engineering. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28092078
ISBN:
9798698534013
Thermo-Mechanical Modeling and the Application of Coiled Polymer Actuators in Soft Robotics and Biomimetics.
Hunt, Robert.
Thermo-Mechanical Modeling and the Application of Coiled Polymer Actuators in Soft Robotics and Biomimetics.
- Ann Arbor : ProQuest Dissertations & Theses, 2020 - 182 p.
Source: Dissertations Abstracts International, Volume: 82-06, Section: B.
Thesis (Ph.D.)--University of Nevada, Las Vegas, 2020.
This item must not be sold to any third party vendors.
Coiled polymer actuators (CPA) are a recently discovered smart material. Due to their large tensile stoke and power densities they are often used as actuators or artificial muscles. CPA's are fabricated from a polymer fiber, typically nylon, mechanically twisted into a coil or coiled around a mandrel and annealed. When heated over the glass transition temperature they can contract, expand or exhibit torsional actuation, depending on the fabrication method and end conditions.The fabrication and application of CPA is well documented and has made many innovations in the fields of smart materials, soft robotics and the likes. However, there is a lack of knowledge in the modeling of CPA, this is partly due to the novelty of the actuator. To address this problem, a theoretical and experimental investigation of thermo-mechanical response is proposed. An energy and variational methods and continuum mechanics approach is utilized with numerical methods to describe the actuation response. To verify the model, the numerical simulation displacement response is compared to CPA samples that are fabricated and experimentally tested in lab using a dynamic machine analyzer (DMA). The results indicate the proposed model accurately predict the actuation response of the CPA under thermal loading. The numerical simulation and experimental comparison is in good agreement and helps to further understand the underlining cause of the actuation behavior of the coiled polymer actuator. Furthermore, the model can be used in application purposes where the results of the model can be used in designing and optimizing soft robotics using CPA as an artificial muscle.In addition to the numerical and experimental investigation of the CPA's thermomechanical response, an application in biomimetics is being studied. Biomimetics is an interdisciplinary field in engineering and sciences used to overcoming complex human challenges by designing and fabricating materials and systems modeled after nature. Applications of biomimicry can be seen in many technological advancements such as catheters, hearing devices, and artificial appendages such as arms, legs and fingers. The inspiration for this study is the hydrofoil like structured pectoral fin of the Harbor Porpoise whale. Studies will be focused on understanding the fluid forces acting on the pectoral fin. First and foremost, a highly accurate pectoral fin is fabricated from CT scans of a Harbor Porpoise whale fin. 3D models are obtained using Simpleware ScanIP and post-processed in Autodesk for 3D printing components, which were used to assemble to artificial whale fin. An array of thermally driven Coiled Polymer Actuators (CPA) fabricated from Nylon and heated with Nichrome are used as artificial muscles for actuating the pectoral fin. CPA's were used for their similarity to biological muscles and are of great interest due to its high specific power and large actuation stroke. A simple control circuit for supplying power to the Nichrome heating wires is developed using an Arduino and motor drivers. The displacement over time of the fin is tested and captured using a laser distant sensor. The fin shows a great displacement response, largely deflecting in both direction relative to its size. The artificial fin was then be further utilized in our studies.The fluid forces imposed on the fin while in motion was measured in a laboratorycontrolled setting. A low-velocity belt driven tow tank was used to displace the artificial fin through water. The tow velocity was varied, and the drag force measurements were taken with and without fin actuation using a cantilever beam load cell. A theoretical derived drag force was compared to the experimental drag data and showed good comparison for the non-actuated fin. Increased drag was exhibited with actuation in both directions when towed through water. This demonstrates the ability of the fin to manipulate is geometry to change the drag force on itself serving as a controllable hydrofoil. We hope to elaborate on this ability and apply it to mechanical designs such as under and above water vehicles.
ISBN: 9798698534013Subjects--Topical Terms:
649730
Mechanical engineering.
Subjects--Index Terms:
Artificial muscle
Thermo-Mechanical Modeling and the Application of Coiled Polymer Actuators in Soft Robotics and Biomimetics.
LDR
:05346nmm a2200385 4500
001
2281730
005
20210920103353.5
008
220723s2020 ||||||||||||||||| ||eng d
020
$a
9798698534013
035
$a
(MiAaPQ)AAI28092078
035
$a
AAI28092078
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Hunt, Robert.
$0
(orcid)0000-0002-2877-8485
$3
3560438
245
1 0
$a
Thermo-Mechanical Modeling and the Application of Coiled Polymer Actuators in Soft Robotics and Biomimetics.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2020
300
$a
182 p.
500
$a
Source: Dissertations Abstracts International, Volume: 82-06, Section: B.
500
$a
Advisor: Kim, Kwang.
502
$a
Thesis (Ph.D.)--University of Nevada, Las Vegas, 2020.
506
$a
This item must not be sold to any third party vendors.
520
$a
Coiled polymer actuators (CPA) are a recently discovered smart material. Due to their large tensile stoke and power densities they are often used as actuators or artificial muscles. CPA's are fabricated from a polymer fiber, typically nylon, mechanically twisted into a coil or coiled around a mandrel and annealed. When heated over the glass transition temperature they can contract, expand or exhibit torsional actuation, depending on the fabrication method and end conditions.The fabrication and application of CPA is well documented and has made many innovations in the fields of smart materials, soft robotics and the likes. However, there is a lack of knowledge in the modeling of CPA, this is partly due to the novelty of the actuator. To address this problem, a theoretical and experimental investigation of thermo-mechanical response is proposed. An energy and variational methods and continuum mechanics approach is utilized with numerical methods to describe the actuation response. To verify the model, the numerical simulation displacement response is compared to CPA samples that are fabricated and experimentally tested in lab using a dynamic machine analyzer (DMA). The results indicate the proposed model accurately predict the actuation response of the CPA under thermal loading. The numerical simulation and experimental comparison is in good agreement and helps to further understand the underlining cause of the actuation behavior of the coiled polymer actuator. Furthermore, the model can be used in application purposes where the results of the model can be used in designing and optimizing soft robotics using CPA as an artificial muscle.In addition to the numerical and experimental investigation of the CPA's thermomechanical response, an application in biomimetics is being studied. Biomimetics is an interdisciplinary field in engineering and sciences used to overcoming complex human challenges by designing and fabricating materials and systems modeled after nature. Applications of biomimicry can be seen in many technological advancements such as catheters, hearing devices, and artificial appendages such as arms, legs and fingers. The inspiration for this study is the hydrofoil like structured pectoral fin of the Harbor Porpoise whale. Studies will be focused on understanding the fluid forces acting on the pectoral fin. First and foremost, a highly accurate pectoral fin is fabricated from CT scans of a Harbor Porpoise whale fin. 3D models are obtained using Simpleware ScanIP and post-processed in Autodesk for 3D printing components, which were used to assemble to artificial whale fin. An array of thermally driven Coiled Polymer Actuators (CPA) fabricated from Nylon and heated with Nichrome are used as artificial muscles for actuating the pectoral fin. CPA's were used for their similarity to biological muscles and are of great interest due to its high specific power and large actuation stroke. A simple control circuit for supplying power to the Nichrome heating wires is developed using an Arduino and motor drivers. The displacement over time of the fin is tested and captured using a laser distant sensor. The fin shows a great displacement response, largely deflecting in both direction relative to its size. The artificial fin was then be further utilized in our studies.The fluid forces imposed on the fin while in motion was measured in a laboratorycontrolled setting. A low-velocity belt driven tow tank was used to displace the artificial fin through water. The tow velocity was varied, and the drag force measurements were taken with and without fin actuation using a cantilever beam load cell. A theoretical derived drag force was compared to the experimental drag data and showed good comparison for the non-actuated fin. Increased drag was exhibited with actuation in both directions when towed through water. This demonstrates the ability of the fin to manipulate is geometry to change the drag force on itself serving as a controllable hydrofoil. We hope to elaborate on this ability and apply it to mechanical designs such as under and above water vehicles.
590
$a
School code: 0506.
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Polymer chemistry.
$3
3173488
650
4
$a
Robotics.
$3
519753
653
$a
Artificial muscle
653
$a
Biomimetics
653
$a
Soft Robotics
653
$a
Tow-tank
653
$a
Twisted and coiled polymer actuator
690
$a
0548
690
$a
0541
690
$a
0495
690
$a
0771
710
2
$a
University of Nevada, Las Vegas.
$b
Mechanical Engineering.
$3
3173299
773
0
$t
Dissertations Abstracts International
$g
82-06B.
790
$a
0506
791
$a
Ph.D.
792
$a
2020
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28092078
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9433463
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login