語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Theory and Practice of Industrial Ap...
~
Liu, Yang.
FindBook
Google Book
Amazon
博客來
Theory and Practice of Industrial Applications of Chromatofocusing for Monoclonal Antibody Purification.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Theory and Practice of Industrial Applications of Chromatofocusing for Monoclonal Antibody Purification./
作者:
Liu, Yang.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2020,
面頁冊數:
360 p.
附註:
Source: Dissertations Abstracts International, Volume: 82-05, Section: B.
Contained By:
Dissertations Abstracts International82-05B.
標題:
Chemical engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28086328
ISBN:
9798691213281
Theory and Practice of Industrial Applications of Chromatofocusing for Monoclonal Antibody Purification.
Liu, Yang.
Theory and Practice of Industrial Applications of Chromatofocusing for Monoclonal Antibody Purification.
- Ann Arbor : ProQuest Dissertations & Theses, 2020 - 360 p.
Source: Dissertations Abstracts International, Volume: 82-05, Section: B.
Thesis (Ph.D.)--University of Maryland, Baltimore County, 2020.
This item must not be sold to any third party vendors.
Chromatofocusing is a special form of ion-exchange chromatography (IEX) that uses a self-generated pH gradient that travels through the column as a set of retained waves. The nonlinear adsorption behavior and displacement effect under mass overloaded conditions that take place in the method make its application particularly interesting for realistic, complex industrial purifications of monoclonal antibodies (mAbs), which are one of the most important types of biopharmaceuticals.This thesis investigated the use of both chromatofocusing and IEX using externally created gradients as the initial capture step in an overall purification process for antibody products. Both methods were found to be useful capture methods in many practical cases. This is especially true for chromatofocusing methods since only a stepwise change is needed to create complex gradient shapes. Results also indicate that chromatofocusing methods have more advantages over the other two IEX methods considered here for host cell proteins (HCPs) removal for the case of acidic to neutral antibody samples, although sometimes a low yield was observed. In addition to the use of chromatofocusing for the capture of mAbs, this study also investigated its use as a polishing method after a protein A capture step. To increase the loading capacity, chromatofocusing was extended from bind-and-elute mode to the overload-and-elute mode. To improve the purity of the product collected when using the latter mode, an auxiliary column was added after the main column. The results obtained indicate that chromatofocusing is useful for removing HCPs and aggregates simultaneously in a polishing step.Two approaches were used and compared for the design of a chromatofocusing pH gradient. One approach employed a mechanistic model based on the local-equilibrium assumption and the coherence conditions. The other approach employed a non-mechanistic model based on a machine-learning, linear regression algorithm. Results indicated that with a limited number of training experiments, which is the case considered here, the use of a mechanistic model for the design and prediction of chromatofocusing pH gradients is more reliable than using a linear-regression model. However, both approaches were found to be useful process development tools depending on the circumstances that apply.
ISBN: 9798691213281Subjects--Topical Terms:
560457
Chemical engineering.
Subjects--Index Terms:
Chromatofocusing
Theory and Practice of Industrial Applications of Chromatofocusing for Monoclonal Antibody Purification.
LDR
:03492nmm a2200349 4500
001
2281265
005
20210910100656.5
008
220723s2020 ||||||||||||||||| ||eng d
020
$a
9798691213281
035
$a
(MiAaPQ)AAI28086328
035
$a
AAI28086328
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Liu, Yang.
$3
1026508
245
1 0
$a
Theory and Practice of Industrial Applications of Chromatofocusing for Monoclonal Antibody Purification.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2020
300
$a
360 p.
500
$a
Source: Dissertations Abstracts International, Volume: 82-05, Section: B.
500
$a
Advisor: Frey, Douglas.
502
$a
Thesis (Ph.D.)--University of Maryland, Baltimore County, 2020.
506
$a
This item must not be sold to any third party vendors.
520
$a
Chromatofocusing is a special form of ion-exchange chromatography (IEX) that uses a self-generated pH gradient that travels through the column as a set of retained waves. The nonlinear adsorption behavior and displacement effect under mass overloaded conditions that take place in the method make its application particularly interesting for realistic, complex industrial purifications of monoclonal antibodies (mAbs), which are one of the most important types of biopharmaceuticals.This thesis investigated the use of both chromatofocusing and IEX using externally created gradients as the initial capture step in an overall purification process for antibody products. Both methods were found to be useful capture methods in many practical cases. This is especially true for chromatofocusing methods since only a stepwise change is needed to create complex gradient shapes. Results also indicate that chromatofocusing methods have more advantages over the other two IEX methods considered here for host cell proteins (HCPs) removal for the case of acidic to neutral antibody samples, although sometimes a low yield was observed. In addition to the use of chromatofocusing for the capture of mAbs, this study also investigated its use as a polishing method after a protein A capture step. To increase the loading capacity, chromatofocusing was extended from bind-and-elute mode to the overload-and-elute mode. To improve the purity of the product collected when using the latter mode, an auxiliary column was added after the main column. The results obtained indicate that chromatofocusing is useful for removing HCPs and aggregates simultaneously in a polishing step.Two approaches were used and compared for the design of a chromatofocusing pH gradient. One approach employed a mechanistic model based on the local-equilibrium assumption and the coherence conditions. The other approach employed a non-mechanistic model based on a machine-learning, linear regression algorithm. Results indicated that with a limited number of training experiments, which is the case considered here, the use of a mechanistic model for the design and prediction of chromatofocusing pH gradients is more reliable than using a linear-regression model. However, both approaches were found to be useful process development tools depending on the circumstances that apply.
590
$a
School code: 0434.
650
4
$a
Chemical engineering.
$3
560457
650
4
$a
Monoclonal antibodies.
$3
603890
650
4
$a
Pharmacology.
$3
634543
650
4
$a
Biochemistry.
$3
518028
653
$a
Chromatofocusing
653
$a
Monoclonal antibody
653
$a
Purification
690
$a
0542
690
$a
0487
690
$a
0419
710
2
$a
University of Maryland, Baltimore County.
$b
Engineering, Chemical and Biochemical.
$3
1669092
773
0
$t
Dissertations Abstracts International
$g
82-05B.
790
$a
0434
791
$a
Ph.D.
792
$a
2020
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28086328
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9432998
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入