A 2D CMUT Array for Liver Elastography.
~
Debnath, Sauparno.
Linked to FindBook
Google Book
Amazon
博客來
A 2D CMUT Array for Liver Elastography.
Record Type:
Electronic resources : Monograph/item
Title/Author:
A 2D CMUT Array for Liver Elastography./
Author:
Debnath, Sauparno.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2021,
Description:
102 p.
Notes:
Source: Masters Abstracts International, Volume: 82-12.
Contained By:
Masters Abstracts International82-12.
Subject:
Electrical engineering. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28416000
ISBN:
9798505546789
A 2D CMUT Array for Liver Elastography.
Debnath, Sauparno.
A 2D CMUT Array for Liver Elastography.
- Ann Arbor : ProQuest Dissertations & Theses, 2021 - 102 p.
Source: Masters Abstracts International, Volume: 82-12.
Thesis (M.A.Sc.)--University of Windsor (Canada), 2021.
This item must not be sold to any third party vendors.
Proper diagnosis of liver disease at an early stage is very crucial for its effective treatment. Chronic liver disease if not treated can often lead to cirrhosis. At present, liver biopsy is the main diagnostic procedure. A non-destructive, patient friendly diagnostic imaging technology is necessary. Piezoelectric transducer used for High Intensity Focused Ultrasound (HIFU) has a narrower bandwidth, thus a single transducer cannot be used for both imaging and HIFU operation. But capacitive micromachined ultrasonic transducers (CMUTs) can be used for both HIFU and imaging. In this thesis work, a unique design has been proposed where a first attempt has been made to design a 2D CMUT array for dual mode operation to detect liver cancer. First is the HIFU mode, where the device transmits a focused ultrasound to the target region in the liver just to momentarily deform (Strain) the liver tissue. Then the same device is switched to second mode which is an imaging mode. In this mode the ultrasonic image is captured using elastography process.Analytical and 3D finite element analysis has been carried out in MATLAB and Intellisuite software, respectively. Bisbenzocyclobutene (BCB), a low K polymer is used as a primary structural material for the CMUT membrane and also for the structure of the CMUT. Gold is used as a top conductor placed on top of the diaphragm. Analytical calculations have been done on several CMUT cells in an array while designing the final array. Elements ranging from 8x8, 16x16, 32x32, and 64x64 have been analyzed. Finally, 64x64 array have been used for best results with a center frequency of 7.5 MHz which are in great agreement with FEA analysis done using Intellisuite software.
ISBN: 9798505546789Subjects--Topical Terms:
649834
Electrical engineering.
Subjects--Index Terms:
Capacitive micromachinedultrasonic transducers
A 2D CMUT Array for Liver Elastography.
LDR
:02867nmm a2200373 4500
001
2280905
005
20210913091742.5
008
220723s2021 ||||||||||||||||| ||eng d
020
$a
9798505546789
035
$a
(MiAaPQ)AAI28416000
035
$a
AAI28416000
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Debnath, Sauparno.
$3
3559470
245
1 0
$a
A 2D CMUT Array for Liver Elastography.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2021
300
$a
102 p.
500
$a
Source: Masters Abstracts International, Volume: 82-12.
500
$a
Advisor: Chowdhury, S.
502
$a
Thesis (M.A.Sc.)--University of Windsor (Canada), 2021.
506
$a
This item must not be sold to any third party vendors.
520
$a
Proper diagnosis of liver disease at an early stage is very crucial for its effective treatment. Chronic liver disease if not treated can often lead to cirrhosis. At present, liver biopsy is the main diagnostic procedure. A non-destructive, patient friendly diagnostic imaging technology is necessary. Piezoelectric transducer used for High Intensity Focused Ultrasound (HIFU) has a narrower bandwidth, thus a single transducer cannot be used for both imaging and HIFU operation. But capacitive micromachined ultrasonic transducers (CMUTs) can be used for both HIFU and imaging. In this thesis work, a unique design has been proposed where a first attempt has been made to design a 2D CMUT array for dual mode operation to detect liver cancer. First is the HIFU mode, where the device transmits a focused ultrasound to the target region in the liver just to momentarily deform (Strain) the liver tissue. Then the same device is switched to second mode which is an imaging mode. In this mode the ultrasonic image is captured using elastography process.Analytical and 3D finite element analysis has been carried out in MATLAB and Intellisuite software, respectively. Bisbenzocyclobutene (BCB), a low K polymer is used as a primary structural material for the CMUT membrane and also for the structure of the CMUT. Gold is used as a top conductor placed on top of the diaphragm. Analytical calculations have been done on several CMUT cells in an array while designing the final array. Elements ranging from 8x8, 16x16, 32x32, and 64x64 have been analyzed. Finally, 64x64 array have been used for best results with a center frequency of 7.5 MHz which are in great agreement with FEA analysis done using Intellisuite software.
590
$a
School code: 0115.
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Oncology.
$3
751006
650
4
$a
Medical imaging.
$3
3172799
653
$a
Capacitive micromachinedultrasonic transducers
653
$a
Liver cancer detection
653
$a
Ultrasound
653
$a
High Intensity Focused Ultrasound
690
$a
0544
690
$a
0574
690
$a
0541
690
$a
0992
710
2
$a
University of Windsor (Canada).
$b
ELECTRICAL ENGINEERING.
$3
3170707
773
0
$t
Masters Abstracts International
$g
82-12.
790
$a
0115
791
$a
M.A.Sc.
792
$a
2021
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28416000
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9432638
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login