Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
The Development of a Fingertip Impla...
~
Du, Lin.
Linked to FindBook
Google Book
Amazon
博客來
The Development of a Fingertip Implantable MEMS Tactile Sensing System.
Record Type:
Electronic resources : Monograph/item
Title/Author:
The Development of a Fingertip Implantable MEMS Tactile Sensing System./
Author:
Du, Lin.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2021,
Description:
150 p.
Notes:
Source: Dissertations Abstracts International, Volume: 82-11, Section: B.
Contained By:
Dissertations Abstracts International82-11B.
Subject:
Electrical engineering. -
Online resource:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28492887
ISBN:
9798738618673
The Development of a Fingertip Implantable MEMS Tactile Sensing System.
Du, Lin.
The Development of a Fingertip Implantable MEMS Tactile Sensing System.
- Ann Arbor : ProQuest Dissertations & Theses, 2021 - 150 p.
Source: Dissertations Abstracts International, Volume: 82-11, Section: B.
Thesis (Ph.D.)--University of Pennsylvania, 2021.
This item is not available from ProQuest Dissertations & Theses.
This thesis explores the development of a fingertip implantable MEMS tactile sensing system to provide tactile sensing capabilities for paralyzed people using a brain machine interface (BMI) technology. With BMI-controlled stimulation, paralyzed people are able to restore hand movement with their native hand without sensation. However, sensory feedback for these BMI-controlled stimulators is still missing. To overcome this barrier, development of a tactile sensing system is necessary. In previous studies, multiple approaches have been exploited to realize fingertip tactile recognition for wearable electronics, prosthetics, and robotics. Compared with these existing tactile sensors with wearable devices or robotic arms, we are interested in combining tactile sensing with implantable MEMS technologies. With this purpose, our goal is to build an implantable tactile sensing system with wireless power and signal transmission capabilities to provide somatosensory feedback in an improved BMI system.One of the most important factors in a successful biomedical MEMS implant is the biocompatible package. In this work, a fused silica package with good hermeticity to moisture, biocompatibility, CMOS compatibility, as well as multiple feedthroughs for electronic access was developed and characterized. A localized fusion bonding technology based on carbon dioxide (CO2) laser assisted machining was proposed to achieve simultaneous bonding and dicing of fused silica wafer stacks, while maintaining temperatures inside the package sufficiently low that electronics are not damaged. To demonstrate an implantable tactile sensor, a capacitive force sensing technology based on the packaging technology was developed to satisfy hermetic and biocompatible requirement for implantation applications. The performance of this tactile sensor is investigated with quantitative static and dynamic loading measurements. In addition, both an in vitro study with the sensor embedded under a skin-phantom, and an in vivo study with implantation of the sensor in a monkey hand are examined. Successful experimental results verify the feasibility of the sensing technology. To further develop an implantable tactile sensing system with wireless communication capability, a multilayer fused silica structure incorporating the capacitive force sensor, an ASIC for wireless power and data communication, and the hermetic package technology for encapsulating the electronics is fabricated. The development of an inductive coil integrated with the system both for energy harvesting and wireless data transmission was presented and fabrication process of the system is discussed. To characterize the tactile sensing system, a customized experimental setup is employed and static loading measurement with dynamic loading analyzer is performed verifying that both the pressure sensing and wireless transmission of the system are functional. This wafer level technology will be very useful for other implantable pressure sensing and micro-opto-electro-mechanical systems (MOEMS) applications.
ISBN: 9798738618673Subjects--Topical Terms:
649834
Electrical engineering.
Subjects--Index Terms:
Fused silica
The Development of a Fingertip Implantable MEMS Tactile Sensing System.
LDR
:04521nmm a2200421 4500
001
2280472
005
20210827095959.5
008
220723s2021 ||||||||||||||||| ||eng d
020
$a
9798738618673
035
$a
(MiAaPQ)AAI28492887
035
$a
AAI28492887
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Du, Lin.
$3
3559001
245
1 4
$a
The Development of a Fingertip Implantable MEMS Tactile Sensing System.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2021
300
$a
150 p.
500
$a
Source: Dissertations Abstracts International, Volume: 82-11, Section: B.
500
$a
Advisor: Allen, Mark G.
502
$a
Thesis (Ph.D.)--University of Pennsylvania, 2021.
506
$a
This item is not available from ProQuest Dissertations & Theses.
506
$a
This item is not available from ProQuest Dissertations & Theses.
506
$a
This item must not be sold to any third party vendors.
506
$a
This item must not be sold to any third party vendors.
520
$a
This thesis explores the development of a fingertip implantable MEMS tactile sensing system to provide tactile sensing capabilities for paralyzed people using a brain machine interface (BMI) technology. With BMI-controlled stimulation, paralyzed people are able to restore hand movement with their native hand without sensation. However, sensory feedback for these BMI-controlled stimulators is still missing. To overcome this barrier, development of a tactile sensing system is necessary. In previous studies, multiple approaches have been exploited to realize fingertip tactile recognition for wearable electronics, prosthetics, and robotics. Compared with these existing tactile sensors with wearable devices or robotic arms, we are interested in combining tactile sensing with implantable MEMS technologies. With this purpose, our goal is to build an implantable tactile sensing system with wireless power and signal transmission capabilities to provide somatosensory feedback in an improved BMI system.One of the most important factors in a successful biomedical MEMS implant is the biocompatible package. In this work, a fused silica package with good hermeticity to moisture, biocompatibility, CMOS compatibility, as well as multiple feedthroughs for electronic access was developed and characterized. A localized fusion bonding technology based on carbon dioxide (CO2) laser assisted machining was proposed to achieve simultaneous bonding and dicing of fused silica wafer stacks, while maintaining temperatures inside the package sufficiently low that electronics are not damaged. To demonstrate an implantable tactile sensor, a capacitive force sensing technology based on the packaging technology was developed to satisfy hermetic and biocompatible requirement for implantation applications. The performance of this tactile sensor is investigated with quantitative static and dynamic loading measurements. In addition, both an in vitro study with the sensor embedded under a skin-phantom, and an in vivo study with implantation of the sensor in a monkey hand are examined. Successful experimental results verify the feasibility of the sensing technology. To further develop an implantable tactile sensing system with wireless communication capability, a multilayer fused silica structure incorporating the capacitive force sensor, an ASIC for wireless power and data communication, and the hermetic package technology for encapsulating the electronics is fabricated. The development of an inductive coil integrated with the system both for energy harvesting and wireless data transmission was presented and fabrication process of the system is discussed. To characterize the tactile sensing system, a customized experimental setup is employed and static loading measurement with dynamic loading analyzer is performed verifying that both the pressure sensing and wireless transmission of the system are functional. This wafer level technology will be very useful for other implantable pressure sensing and micro-opto-electro-mechanical systems (MOEMS) applications.
590
$a
School code: 0175.
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Computer science.
$3
523869
650
4
$a
Bioengineering.
$3
657580
653
$a
Fused silica
653
$a
Implantable system
653
$a
Microelectromechanical Systems
653
$a
Tactile sensing
653
$a
Fingertip implants
653
$a
Brain Machine Interface
690
$a
0544
690
$a
0202
690
$a
0984
710
2
$a
University of Pennsylvania.
$b
Electrical and Systems Engineering.
$3
3169654
773
0
$t
Dissertations Abstracts International
$g
82-11B.
790
$a
0175
791
$a
Ph.D.
792
$a
2021
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28492887
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9432205
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login