語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
The MicroHammer: Investigating Cellu...
~
Patterson, Luke H.C.
FindBook
Google Book
Amazon
博客來
The MicroHammer: Investigating Cellular Response to Impact with a Microfluidic Mems Device.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
The MicroHammer: Investigating Cellular Response to Impact with a Microfluidic Mems Device./
作者:
Patterson, Luke H.C.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2020,
面頁冊數:
136 p.
附註:
Source: Dissertations Abstracts International, Volume: 82-05, Section: B.
Contained By:
Dissertations Abstracts International82-05B.
標題:
Mechanical engineering. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28094715
ISBN:
9798684682148
The MicroHammer: Investigating Cellular Response to Impact with a Microfluidic Mems Device.
Patterson, Luke H.C.
The MicroHammer: Investigating Cellular Response to Impact with a Microfluidic Mems Device.
- Ann Arbor : ProQuest Dissertations & Theses, 2020 - 136 p.
Source: Dissertations Abstracts International, Volume: 82-05, Section: B.
Thesis (Ph.D.)--University of California, Santa Barbara, 2020.
This item must not be sold to any third party vendors.
Although high strain and strain-rate impacts to the human body have been the subject of substantial research at both the systemic and tissue levels, little is known about the cell-level ramifications of such assaults. This is largely due to the lack of high throughput, dynamic compression devices capable of simulating such traumatic loading conditions on individual cells. Understanding the mechanical response to impact on the cellular level is important, since it can elucidate the fundamental mechanisms of damage following impact to vulnerable tissue like the brain and cartilage, providing a window into potential targets for therapy. To fill this gap, my collaborators and I have developed and characterized a high speed, high actuation force, magnetically driven MEMS chip to apply compression to biological cells with an unprecedented combination of strain (10% to 90%), strain rate (30,000 to 200,000 s-1), and throughput (10,000 to 1,000,000 cells/experiment). To demonstrate the cell-impact capabilities of the μHammer, we applied biologically relevant strains and strain rates to human leukemic K562 cells and then monitored their viability for up to 8 days. We observed significantly repressed proliferation of the hit cells compared to both unperturbed and sham-hit control cells, accompanied by minimal cell death. This indicates success in applying cellular damage without compromising the overall viability of the population.Once we validated the µHammer's ability to impact cells, we sought to fully leverage the high-throughput capabilities of the device by optimizing the experimental conditions of the fluid and cells (or other particles) flowing through it. Parameters such as flow velocity and particle size are known to affect the trajectories of particles in microfluidic systems and have been studied extensively, but the effects of temperature and buffer viscosity are not as well understood. To explore the effects of these parameters on the performance of the µHammer, we first tracked the velocity of polystyrene beads through the device and then visualized the impact of these beads. Through these assays, we find that the timing of our device is sensitive to changes in the ratio of inertial forces to viscous forces that particles experience while traveling through the µHammer. This sensitivity provides a set of parameters that can serve as a robust framework for optimizing the performance of microfluidic devices under various experimental conditions. Using this framework, we achieved an effective throughput over 360 particles/s with the µHammer and proposed geometric redesigns which could further improve device performance in future experiments. In the end, the impact parameters applied by the µHammer to each of these particles align with those experienced by individual cells during traumatic impacts in the brain and cartilage, allowing us to conclude that this device is well-suited to study the subtle effects of impact on large populations of inherently heterogeneous cells.
ISBN: 9798684682148Subjects--Topical Terms:
649730
Mechanical engineering.
Subjects--Index Terms:
Cell impact
The MicroHammer: Investigating Cellular Response to Impact with a Microfluidic Mems Device.
LDR
:04440nmm a2200469 4500
001
2280419
005
20210827095945.5
008
220723s2020 ||||||||||||||||| ||eng d
020
$a
9798684682148
035
$a
(MiAaPQ)AAI28094715
035
$a
AAI28094715
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Patterson, Luke H.C.
$3
3558934
245
1 4
$a
The MicroHammer: Investigating Cellular Response to Impact with a Microfluidic Mems Device.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2020
300
$a
136 p.
500
$a
Source: Dissertations Abstracts International, Volume: 82-05, Section: B.
500
$a
Advisor: Foster, Kimberly L.
502
$a
Thesis (Ph.D.)--University of California, Santa Barbara, 2020.
506
$a
This item must not be sold to any third party vendors.
520
$a
Although high strain and strain-rate impacts to the human body have been the subject of substantial research at both the systemic and tissue levels, little is known about the cell-level ramifications of such assaults. This is largely due to the lack of high throughput, dynamic compression devices capable of simulating such traumatic loading conditions on individual cells. Understanding the mechanical response to impact on the cellular level is important, since it can elucidate the fundamental mechanisms of damage following impact to vulnerable tissue like the brain and cartilage, providing a window into potential targets for therapy. To fill this gap, my collaborators and I have developed and characterized a high speed, high actuation force, magnetically driven MEMS chip to apply compression to biological cells with an unprecedented combination of strain (10% to 90%), strain rate (30,000 to 200,000 s-1), and throughput (10,000 to 1,000,000 cells/experiment). To demonstrate the cell-impact capabilities of the μHammer, we applied biologically relevant strains and strain rates to human leukemic K562 cells and then monitored their viability for up to 8 days. We observed significantly repressed proliferation of the hit cells compared to both unperturbed and sham-hit control cells, accompanied by minimal cell death. This indicates success in applying cellular damage without compromising the overall viability of the population.Once we validated the µHammer's ability to impact cells, we sought to fully leverage the high-throughput capabilities of the device by optimizing the experimental conditions of the fluid and cells (or other particles) flowing through it. Parameters such as flow velocity and particle size are known to affect the trajectories of particles in microfluidic systems and have been studied extensively, but the effects of temperature and buffer viscosity are not as well understood. To explore the effects of these parameters on the performance of the µHammer, we first tracked the velocity of polystyrene beads through the device and then visualized the impact of these beads. Through these assays, we find that the timing of our device is sensitive to changes in the ratio of inertial forces to viscous forces that particles experience while traveling through the µHammer. This sensitivity provides a set of parameters that can serve as a robust framework for optimizing the performance of microfluidic devices under various experimental conditions. Using this framework, we achieved an effective throughput over 360 particles/s with the µHammer and proposed geometric redesigns which could further improve device performance in future experiments. In the end, the impact parameters applied by the µHammer to each of these particles align with those experienced by individual cells during traumatic impacts in the brain and cartilage, allowing us to conclude that this device is well-suited to study the subtle effects of impact on large populations of inherently heterogeneous cells.
590
$a
School code: 0035.
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Biomechanics.
$3
548685
650
4
$a
Systematic biology.
$3
3173492
650
4
$a
Cellular biology.
$3
3172791
650
4
$a
Histology.
$3
641250
650
4
$a
Genetics.
$3
530508
653
$a
Cell impact
653
$a
Dynamic cell compression
653
$a
Inertial focusing
653
$a
MEMS
653
$a
Microfluidics
653
$a
Traumatic Brain Injury
653
$a
MEMs chip
653
$a
Vulnerable tissues
653
$a
Microfluidic devices
690
$a
0548
690
$a
0541
690
$a
0648
690
$a
0423
690
$a
0379
690
$a
0369
690
$a
0414
710
2
$a
University of California, Santa Barbara.
$b
Mechanical Engineering.
$3
1018391
773
0
$t
Dissertations Abstracts International
$g
82-05B.
790
$a
0035
791
$a
Ph.D.
792
$a
2020
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28094715
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9432152
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入