Feasibility Assessments of Combined Cooling, Heating, and Power (CCHP) Systems for Commercial Buildings.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Feasibility Assessments of Combined Cooling, Heating, and Power (CCHP) Systems for Commercial Buildings./
作者:
Ahn, Hyeunguk.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2019,
面頁冊數:
187 p.
附註:
Source: Dissertations Abstracts International, Volume: 82-02, Section: B.
Contained By:
Dissertations Abstracts International82-02B.
標題:
Alternative energy. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28123428
ISBN:
9798662542914
Feasibility Assessments of Combined Cooling, Heating, and Power (CCHP) Systems for Commercial Buildings.
Ahn, Hyeunguk.
Feasibility Assessments of Combined Cooling, Heating, and Power (CCHP) Systems for Commercial Buildings.
- Ann Arbor : ProQuest Dissertations & Theses, 2019 - 187 p.
Source: Dissertations Abstracts International, Volume: 82-02, Section: B.
Thesis (Ph.D.)--The Pennsylvania State University, 2019.
Distributed energy systems produce energy on-site considerably reducing energy loss that would occur when energy is supplied from centralized systems. One of the distributed energy technologies is a combined cooling, heating, and power (CCHP) system. In a CCHP system, electricity is generated near end-users and the recovered heat from a power generation unit is utilized for cooling and heating in a building. Therefore, CCHP systems can increase primary energy utilization efficiency and energy reliability while reducing adverse environmental impacts. CCHP systems can be applicable from a building to community level. However, the feasibility of CCHP systems can largely vary with building type and location as well as other integrated subsystems such as hybrid chiller and solar photovoltaic (PV) systems. This dissertation focuses on feasibility assessments of CCHP systems integrated with hybrid chiller and PV systems. Specifically, the work in this dissertation consists of investigations of energy, environmental, and economic performances of CCHP systems applied to various commercial building types in different climatic regions in the U.S.The first investigation evaluates the energy and environmental performances of CCHP systems operating with two distinct cooling systems (i.e., absorption chiller vs. hybrid chiller) based on primary energy consumption and carbon dioxide emission. This study focuses on a hospital and an office building in San Francisco, CA and Long Island, NY. The results show that CCHP hybrid chiller systems can reduce a significant amount of primary energy consumption than traditional CCHP systems that utilize only an absorption chiller, especially when the systems are applied to a hospital building. The significant reduction of the primary energy consumption is mainly because a hybrid chiller system can minimize undesirable boiler operations for absorption cooling. The reduced primary energy consumption can also lead to a decrease in carbon dioxide emissions although regionally-varying emission factors of the grid electricity notably influence the environmental performance of CCHP hybrid chiller systems.The second investigation focuses on the economic feasibility of different-sized CCHP hybrid chiller systems for large office buildings considering realistic electricity tariff structures in different geographic regions including San Francisco, CA; Boston, MA; and Miami, FL. The results show that CCHP hybrid chiller systems can be economically justifiable for regions with relatively high electricity price and low natural gas price such as San Francisco and Boston. The cost savings are mainly attributed to electricity cost savings. Specifically, if a local electricity tariff estimates demand charges as high as energy charges (e.g., a tariff structure in San Francisco), demand charges can contribute to about 40% of the electricity cost savings; thus, using simplified tariff structures that neglect demand charges can result in a noticeable discrepancy in economic analyses of CCHP systems or other analogous distributed energy systems. However, for regions with relatively high natural gas price and low electricity price (e.g., Miami), the operation cost of CCHP hybrid chiller systems is higher up to $0.4 million per year compared to that of a conventional separate heat and power (SHP) system.The third investigation integrates solar PV panels with CCHP hybrid chiller (CCHP+PV) systems as applied to a large office building in San Francisco, CA and examines the impacts of variabilities in energy demands and solar irradiance on the energy and economic performances of CCHP+PV systems. According to the results obtained in this study, the associated uncertainties marginally influence the energy performance of CCHP+PV systems whereas they can increase the operation cost by up to $75,000 per year. Such a great increase in the operation cost is mainly attributed to demand charges that tend to increase as the uncertainties are considered. This result implies that a deterministic model of a CCHP+PV system may significantly underestimate its operation costs and overestimate economic savings, thereby leading to overly optimistic economic viability.
ISBN: 9798662542914Subjects--Topical Terms:
3436775
Alternative energy.
Subjects--Index Terms:
Distributed energy systems
Feasibility Assessments of Combined Cooling, Heating, and Power (CCHP) Systems for Commercial Buildings.
LDR
:05302nmm a2200325 4500
001
2277391
005
20210521101713.5
008
220723s2019 ||||||||||||||||| ||eng d
020
$a
9798662542914
035
$a
(MiAaPQ)AAI28123428
035
$a
AAI28123428
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Ahn, Hyeunguk.
$3
3555704
245
1 0
$a
Feasibility Assessments of Combined Cooling, Heating, and Power (CCHP) Systems for Commercial Buildings.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2019
300
$a
187 p.
500
$a
Source: Dissertations Abstracts International, Volume: 82-02, Section: B.
500
$a
Advisor: Freihaut, James D.;Rim, Donghyun.
502
$a
Thesis (Ph.D.)--The Pennsylvania State University, 2019.
520
$a
Distributed energy systems produce energy on-site considerably reducing energy loss that would occur when energy is supplied from centralized systems. One of the distributed energy technologies is a combined cooling, heating, and power (CCHP) system. In a CCHP system, electricity is generated near end-users and the recovered heat from a power generation unit is utilized for cooling and heating in a building. Therefore, CCHP systems can increase primary energy utilization efficiency and energy reliability while reducing adverse environmental impacts. CCHP systems can be applicable from a building to community level. However, the feasibility of CCHP systems can largely vary with building type and location as well as other integrated subsystems such as hybrid chiller and solar photovoltaic (PV) systems. This dissertation focuses on feasibility assessments of CCHP systems integrated with hybrid chiller and PV systems. Specifically, the work in this dissertation consists of investigations of energy, environmental, and economic performances of CCHP systems applied to various commercial building types in different climatic regions in the U.S.The first investigation evaluates the energy and environmental performances of CCHP systems operating with two distinct cooling systems (i.e., absorption chiller vs. hybrid chiller) based on primary energy consumption and carbon dioxide emission. This study focuses on a hospital and an office building in San Francisco, CA and Long Island, NY. The results show that CCHP hybrid chiller systems can reduce a significant amount of primary energy consumption than traditional CCHP systems that utilize only an absorption chiller, especially when the systems are applied to a hospital building. The significant reduction of the primary energy consumption is mainly because a hybrid chiller system can minimize undesirable boiler operations for absorption cooling. The reduced primary energy consumption can also lead to a decrease in carbon dioxide emissions although regionally-varying emission factors of the grid electricity notably influence the environmental performance of CCHP hybrid chiller systems.The second investigation focuses on the economic feasibility of different-sized CCHP hybrid chiller systems for large office buildings considering realistic electricity tariff structures in different geographic regions including San Francisco, CA; Boston, MA; and Miami, FL. The results show that CCHP hybrid chiller systems can be economically justifiable for regions with relatively high electricity price and low natural gas price such as San Francisco and Boston. The cost savings are mainly attributed to electricity cost savings. Specifically, if a local electricity tariff estimates demand charges as high as energy charges (e.g., a tariff structure in San Francisco), demand charges can contribute to about 40% of the electricity cost savings; thus, using simplified tariff structures that neglect demand charges can result in a noticeable discrepancy in economic analyses of CCHP systems or other analogous distributed energy systems. However, for regions with relatively high natural gas price and low electricity price (e.g., Miami), the operation cost of CCHP hybrid chiller systems is higher up to $0.4 million per year compared to that of a conventional separate heat and power (SHP) system.The third investigation integrates solar PV panels with CCHP hybrid chiller (CCHP+PV) systems as applied to a large office building in San Francisco, CA and examines the impacts of variabilities in energy demands and solar irradiance on the energy and economic performances of CCHP+PV systems. According to the results obtained in this study, the associated uncertainties marginally influence the energy performance of CCHP+PV systems whereas they can increase the operation cost by up to $75,000 per year. Such a great increase in the operation cost is mainly attributed to demand charges that tend to increase as the uncertainties are considered. This result implies that a deterministic model of a CCHP+PV system may significantly underestimate its operation costs and overestimate economic savings, thereby leading to overly optimistic economic viability.
590
$a
School code: 0176.
650
4
$a
Alternative energy.
$3
3436775
650
4
$a
Architectural engineering.
$3
3174102
653
$a
Distributed energy systems
653
$a
Solar photovoltaic systems
653
$a
Cooling systems
690
$a
0363
690
$a
0462
710
2
$a
The Pennsylvania State University.
$3
699896
773
0
$t
Dissertations Abstracts International
$g
82-02B.
790
$a
0176
791
$a
Ph.D.
792
$a
2019
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28123428
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9429125
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入