語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Critical Analysis of an Electro-Hydr...
~
Porter, Charles.
FindBook
Google Book
Amazon
博客來
Critical Analysis of an Electro-Hydraulic Servo Valve Opening Under Steady-State and Transient Conditions.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Critical Analysis of an Electro-Hydraulic Servo Valve Opening Under Steady-State and Transient Conditions./
作者:
Porter, Charles.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2020,
面頁冊數:
75 p.
附註:
Source: Masters Abstracts International, Volume: 82-04.
Contained By:
Masters Abstracts International82-04.
標題:
Fluid mechanics. -
電子資源:
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28031519
ISBN:
9798678140746
Critical Analysis of an Electro-Hydraulic Servo Valve Opening Under Steady-State and Transient Conditions.
Porter, Charles.
Critical Analysis of an Electro-Hydraulic Servo Valve Opening Under Steady-State and Transient Conditions.
- Ann Arbor : ProQuest Dissertations & Theses, 2020 - 75 p.
Source: Masters Abstracts International, Volume: 82-04.
Thesis (M.Sc.)--University of Central Oklahoma, 2020.
This item must not be sold to any third party vendors.
Electro-Hydraulic servo valves (EHSV) are used extensively in industrial applications due to their lightweight design, inexpensive manufacturing, simple operating technology, and modularity. EHSV are used in military, industrial, aviation, and other applications. The engineering design, testing and prototyping of EHSV as implemented in a given fluid system can be expensive and time consuming. Improvements made in computational modeling and simulation of system designs that include EHSV can reduce time and cost in implementing EHSV in fluid systems by leveraging computational capabilities to predict performance of EHSV.The operating principles and flow effects of EHSV used in industry are often difficult to predict in a particular fluid system. Simulation of EHSV has the potential to improve prediction of performance in given systems, but the challenge is that simulating flow in EHSV can be very challenging due to transient (TR) flow and dynamic geometries.This thesis focuses on simulating fluid flow at various times as an EHSV is opening to determine flow parameters for a specific industrial EHSV design utilizing steady-state (SS) and TR modeling. Consistency between SS and TR techniques is calculated. Data from a similar experimental system is compared to determine simulation accuracy and evaluate modeling effectiveness of SS and TR techniques.The standard k-ε method for modeling turbulence in the system was utilized to simulate a valve opening under both SS and TR conditions. In the TR simulation dynamic meshing was utilized for the region where the mesh moves model valve opening.Simulation results show similarities in flow profiles and parameters between SS and TR models. Dynamic meshing near the valve opening, when the valve just begins to open, induces error throughout the system and effects all flow field parameters studied in this thesis.The SS and TR models each have an area where their accuracy is optimum. Steady-state modeling provides better accuracy where dynamic meshing may induce error for small geometries and gaps, while dynamic TR modeling is more accurate for larger less complicated mesh structures. The SS simulation averaged a 7.96% difference from the experimental values over the range of 1.95mm ≥XL ≥4.17mm, where XL is the distance a control spool has moved to open the valve, while the TR simulation averaged 7.81% difference. The difference in accuracy between the two different type of models would be negligible in most applications for valve design. The TR simulation averaged an 7.86% difference from the experimental values over the range of 4.17 mm ≥ XL ≥ 7.87 mm, while the SS simulation averaged 17.52% accuracy over that same range. A difference of approximately 9.66% may be significant enough to effect design.These values provide insight into simplifying simulated models for applications where accuracy reduction is an acceptable trade-off for time and computational expense related to performing more complicated and difficult models such as a dynamic and transient model. Further research may be conducted into simplifying models and simulation for industry design applications.
ISBN: 9798678140746Subjects--Topical Terms:
528155
Fluid mechanics.
Subjects--Index Terms:
CFD
Critical Analysis of an Electro-Hydraulic Servo Valve Opening Under Steady-State and Transient Conditions.
LDR
:04296nmm a2200373 4500
001
2276731
005
20210510091859.5
008
220723s2020 ||||||||||||||||| ||eng d
020
$a
9798678140746
035
$a
(MiAaPQ)AAI28031519
035
$a
AAI28031519
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Porter, Charles.
$3
3555025
245
1 0
$a
Critical Analysis of an Electro-Hydraulic Servo Valve Opening Under Steady-State and Transient Conditions.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2020
300
$a
75 p.
500
$a
Source: Masters Abstracts International, Volume: 82-04.
500
$a
Advisor: Lemley, Evan.
502
$a
Thesis (M.Sc.)--University of Central Oklahoma, 2020.
506
$a
This item must not be sold to any third party vendors.
520
$a
Electro-Hydraulic servo valves (EHSV) are used extensively in industrial applications due to their lightweight design, inexpensive manufacturing, simple operating technology, and modularity. EHSV are used in military, industrial, aviation, and other applications. The engineering design, testing and prototyping of EHSV as implemented in a given fluid system can be expensive and time consuming. Improvements made in computational modeling and simulation of system designs that include EHSV can reduce time and cost in implementing EHSV in fluid systems by leveraging computational capabilities to predict performance of EHSV.The operating principles and flow effects of EHSV used in industry are often difficult to predict in a particular fluid system. Simulation of EHSV has the potential to improve prediction of performance in given systems, but the challenge is that simulating flow in EHSV can be very challenging due to transient (TR) flow and dynamic geometries.This thesis focuses on simulating fluid flow at various times as an EHSV is opening to determine flow parameters for a specific industrial EHSV design utilizing steady-state (SS) and TR modeling. Consistency between SS and TR techniques is calculated. Data from a similar experimental system is compared to determine simulation accuracy and evaluate modeling effectiveness of SS and TR techniques.The standard k-ε method for modeling turbulence in the system was utilized to simulate a valve opening under both SS and TR conditions. In the TR simulation dynamic meshing was utilized for the region where the mesh moves model valve opening.Simulation results show similarities in flow profiles and parameters between SS and TR models. Dynamic meshing near the valve opening, when the valve just begins to open, induces error throughout the system and effects all flow field parameters studied in this thesis.The SS and TR models each have an area where their accuracy is optimum. Steady-state modeling provides better accuracy where dynamic meshing may induce error for small geometries and gaps, while dynamic TR modeling is more accurate for larger less complicated mesh structures. The SS simulation averaged a 7.96% difference from the experimental values over the range of 1.95mm ≥XL ≥4.17mm, where XL is the distance a control spool has moved to open the valve, while the TR simulation averaged 7.81% difference. The difference in accuracy between the two different type of models would be negligible in most applications for valve design. The TR simulation averaged an 7.86% difference from the experimental values over the range of 4.17 mm ≥ XL ≥ 7.87 mm, while the SS simulation averaged 17.52% accuracy over that same range. A difference of approximately 9.66% may be significant enough to effect design.These values provide insight into simplifying simulated models for applications where accuracy reduction is an acceptable trade-off for time and computational expense related to performing more complicated and difficult models such as a dynamic and transient model. Further research may be conducted into simplifying models and simulation for industry design applications.
590
$a
School code: 0503.
650
4
$a
Fluid mechanics.
$3
528155
650
4
$a
Industrial engineering.
$3
526216
650
4
$a
Hydraulic engineering.
$3
613609
653
$a
CFD
653
$a
Electrohydraulic
653
$a
Servo
653
$a
Simulation
653
$a
Valve
690
$a
0204
690
$a
0546
690
$a
0218
710
2
$a
University of Central Oklahoma.
$b
Engineering & Physics.
$3
3347741
773
0
$t
Masters Abstracts International
$g
82-04.
790
$a
0503
791
$a
M.Sc.
792
$a
2020
793
$a
English
856
4 0
$u
https://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=28031519
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9428465
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入