語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Domain Broadening in Periodic Poling...
~
Bullen, Peter S.
FindBook
Google Book
Amazon
博客來
Domain Broadening in Periodic Poling of Thinned Lithium Niobate and Spectroscopic Methods for Whole Blood Analysis.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Domain Broadening in Periodic Poling of Thinned Lithium Niobate and Spectroscopic Methods for Whole Blood Analysis./
作者:
Bullen, Peter S.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2019,
面頁冊數:
110 p.
附註:
Source: Dissertations Abstracts International, Volume: 80-09, Section: B.
Contained By:
Dissertations Abstracts International80-09B.
標題:
Applied physics. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13805814
ISBN:
9781392007785
Domain Broadening in Periodic Poling of Thinned Lithium Niobate and Spectroscopic Methods for Whole Blood Analysis.
Bullen, Peter S.
Domain Broadening in Periodic Poling of Thinned Lithium Niobate and Spectroscopic Methods for Whole Blood Analysis.
- Ann Arbor : ProQuest Dissertations & Theses, 2019 - 110 p.
Source: Dissertations Abstracts International, Volume: 80-09, Section: B.
Thesis (Ph.D.)--Columbia University, 2019.
This item is not available from ProQuest Dissertations & Theses.
This dissertation is divided into two separate parts covering my research in two different fields of optics. Part I consists of chapters 1-3 and covers experiments on periodically poled lithium niobate while Part II consists of chapters 4-6 and covers various spectroscopic methods designed for the application of in vivo blood analysis. Chapter 1 serves as a brief introduction to periodically poled lithium niobate and its fabrication process. In chapter 2, the key results of Part I, derived from a series of experiments on poling of thinned lithium niobate, are presented. Building upon these experiments, chapter 3 concludes Part I with a study on poling of crystal ion sliced lithium niobate. Part II begins with chapter 4, which describes a spectroscopic approach for non-invasive blood analysis in vivo. In chapter 5, experiments analyzing aqueous glucose solutions with mid-infrared and Raman spectroscopy are discussed. Chapter 6 concludes this dissertation with the design and demonstration of a innovative stimulated Raman spectroscopy system. In Part I, ferroelectric poling fabrication procedures were developed, optimized, and implemented for periodic poling of thinned lithium niobate. The free-standing samples of thickness from 500 µm down to 25 µm were thinned by chemical mechanical planarization and annealed before poling. Domain structure was investigated as a function of sample thickness using Raman, scanning electron, atomic force, and optical microscopy, and broadening of poled domains was consistently found to vary with sample thickness in a strong linear correlation. Domain broadening was reduced by 38% as the thickness of the poled sample was reduced from 500 to 25 µm. Micro Raman probe measurements showed a thickness-dependent contrast in Raman active mode intensity between poled and unpoled regions, with the thinner samples having a higher intensity contrast. To explore poling on even thinner free-standing samples, crystal ion sliced lithium niobate thin films of 10 µm in thickness were fabricated. Chemical mechanical planarization of the ion-implanted layer and annealing was performed to prepare the thin films for poling. Ferroelectric poling of the crystal ion sliced samples was attempted, but unsuccessful, suggesting that alternative fabrication processes may be necessary for poling of crystal ion sliced thin films. In Part II, several disparate experiments were conducted to progress towards a common overarching goal of developing a spectroscopic method for non-invasive whole blood analysis and metabolite monitoring. A portable visible and near-infrared spectroscopy system for in vivo blood spectral identification was developed and demonstrated in a clinical setting. A custom-designed clip attached the illumination and collection optics to opposite sides of the patients' fifth fingertip, and applied gentle pressure, gradually pushing a small quantity of blood away from the measurement site, and inducing a time-dependent change in the effective path length of blood. Time-dependent visible and near-infrared spectra were measured from the collected transmitted and scattered light. A maximum likelihood model was developed to leverage the time-dependent spectral component and identify the spectrum of blood, isolating it from that of surrounding tissue. A second set of experiments were conducted to develop a model for predicting glucose concentrations from measured mid-infrared transmission and spontaneous Raman scattering spectra. Partial least squares regression models were trained, validated, and tested on the spectra of aqueous 0-10 mM glucose solutions measured by both spectroscopic modalies. The models proved to be accurate predictors of glucose concentration as the mean squared error of the model based on mid-infrared spectra ranged from 0.10-0.74 mM, and that of the Raman-based model ranged from 0.26-0.93 mM. Finally, an LED-based stimulated Raman system was innovated to improve upon the relatively weak spontaneous Raman signal in a cost-effective manner. Stimulated Raman gain using a broadband LED Stokes source was demonstrated in the measuring of vibrational spectra of aqueous 0-10 mM glucose solutions. Scattered light was detected via photomultiplier tube and measured using either a photon counter or a lock-in amplifier in two alternative versions of the system. Both stimulated and spontaneous Raman spectra were collected with each instrument for a total of four measurement modalities. The stimulated Raman spectra measured with the photon counter showed up to 100% higher intensity for some glucose modes compared to the corresponding spontaneous Raman spectra, but also had significantly greater noise. For the spectra measured with the lock-in amplifier, the glucose modes of the stimulated Raman spectra were only 20-30% higher in intensity than those of the spontaneous Raman spectra, but had similar levels of noise. Partial least squares regression models based on spectra measured by each modality were developed and compared. (Abstract shortened by ProQuest.).
ISBN: 9781392007785Subjects--Topical Terms:
3343996
Applied physics.
Subjects--Index Terms:
Domain broadening
Domain Broadening in Periodic Poling of Thinned Lithium Niobate and Spectroscopic Methods for Whole Blood Analysis.
LDR
:06461nmm a2200409 4500
001
2272376
005
20201105110040.5
008
220629s2019 ||||||||||||||||| ||eng d
020
$a
9781392007785
035
$a
(MiAaPQ)AAI13805814
035
$a
(MiAaPQ)columbia:15087
035
$a
AAI13805814
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Bullen, Peter S.
$3
3549809
245
1 0
$a
Domain Broadening in Periodic Poling of Thinned Lithium Niobate and Spectroscopic Methods for Whole Blood Analysis.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2019
300
$a
110 p.
500
$a
Source: Dissertations Abstracts International, Volume: 80-09, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Kymissis, Ioannis.
502
$a
Thesis (Ph.D.)--Columbia University, 2019.
506
$a
This item is not available from ProQuest Dissertations & Theses.
506
$a
This item must not be sold to any third party vendors.
520
$a
This dissertation is divided into two separate parts covering my research in two different fields of optics. Part I consists of chapters 1-3 and covers experiments on periodically poled lithium niobate while Part II consists of chapters 4-6 and covers various spectroscopic methods designed for the application of in vivo blood analysis. Chapter 1 serves as a brief introduction to periodically poled lithium niobate and its fabrication process. In chapter 2, the key results of Part I, derived from a series of experiments on poling of thinned lithium niobate, are presented. Building upon these experiments, chapter 3 concludes Part I with a study on poling of crystal ion sliced lithium niobate. Part II begins with chapter 4, which describes a spectroscopic approach for non-invasive blood analysis in vivo. In chapter 5, experiments analyzing aqueous glucose solutions with mid-infrared and Raman spectroscopy are discussed. Chapter 6 concludes this dissertation with the design and demonstration of a innovative stimulated Raman spectroscopy system. In Part I, ferroelectric poling fabrication procedures were developed, optimized, and implemented for periodic poling of thinned lithium niobate. The free-standing samples of thickness from 500 µm down to 25 µm were thinned by chemical mechanical planarization and annealed before poling. Domain structure was investigated as a function of sample thickness using Raman, scanning electron, atomic force, and optical microscopy, and broadening of poled domains was consistently found to vary with sample thickness in a strong linear correlation. Domain broadening was reduced by 38% as the thickness of the poled sample was reduced from 500 to 25 µm. Micro Raman probe measurements showed a thickness-dependent contrast in Raman active mode intensity between poled and unpoled regions, with the thinner samples having a higher intensity contrast. To explore poling on even thinner free-standing samples, crystal ion sliced lithium niobate thin films of 10 µm in thickness were fabricated. Chemical mechanical planarization of the ion-implanted layer and annealing was performed to prepare the thin films for poling. Ferroelectric poling of the crystal ion sliced samples was attempted, but unsuccessful, suggesting that alternative fabrication processes may be necessary for poling of crystal ion sliced thin films. In Part II, several disparate experiments were conducted to progress towards a common overarching goal of developing a spectroscopic method for non-invasive whole blood analysis and metabolite monitoring. A portable visible and near-infrared spectroscopy system for in vivo blood spectral identification was developed and demonstrated in a clinical setting. A custom-designed clip attached the illumination and collection optics to opposite sides of the patients' fifth fingertip, and applied gentle pressure, gradually pushing a small quantity of blood away from the measurement site, and inducing a time-dependent change in the effective path length of blood. Time-dependent visible and near-infrared spectra were measured from the collected transmitted and scattered light. A maximum likelihood model was developed to leverage the time-dependent spectral component and identify the spectrum of blood, isolating it from that of surrounding tissue. A second set of experiments were conducted to develop a model for predicting glucose concentrations from measured mid-infrared transmission and spontaneous Raman scattering spectra. Partial least squares regression models were trained, validated, and tested on the spectra of aqueous 0-10 mM glucose solutions measured by both spectroscopic modalies. The models proved to be accurate predictors of glucose concentration as the mean squared error of the model based on mid-infrared spectra ranged from 0.10-0.74 mM, and that of the Raman-based model ranged from 0.26-0.93 mM. Finally, an LED-based stimulated Raman system was innovated to improve upon the relatively weak spontaneous Raman signal in a cost-effective manner. Stimulated Raman gain using a broadband LED Stokes source was demonstrated in the measuring of vibrational spectra of aqueous 0-10 mM glucose solutions. Scattered light was detected via photomultiplier tube and measured using either a photon counter or a lock-in amplifier in two alternative versions of the system. Both stimulated and spontaneous Raman spectra were collected with each instrument for a total of four measurement modalities. The stimulated Raman spectra measured with the photon counter showed up to 100% higher intensity for some glucose modes compared to the corresponding spontaneous Raman spectra, but also had significantly greater noise. For the spectra measured with the lock-in amplifier, the glucose modes of the stimulated Raman spectra were only 20-30% higher in intensity than those of the spontaneous Raman spectra, but had similar levels of noise. Partial least squares regression models based on spectra measured by each modality were developed and compared. (Abstract shortened by ProQuest.).
590
$a
School code: 0054.
650
4
$a
Applied physics.
$3
3343996
650
4
$a
Optics.
$3
517925
653
$a
Domain broadening
653
$a
In vivo
653
$a
Lithium niobate
653
$a
Periodic poling
653
$a
Spectroscopy
653
$a
Stimulated raman
690
$a
0215
690
$a
0752
710
2
$a
Columbia University.
$b
Applied Physics.
$3
3187824
773
0
$t
Dissertations Abstracts International
$g
80-09B.
790
$a
0054
791
$a
Ph.D.
792
$a
2019
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13805814
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9424610
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入