Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Materials Engineering of Semiconduct...
~
Chern, Margaret.
Linked to FindBook
Google Book
Amazon
博客來
Materials Engineering of Semiconductor Quantum Dots for Biosensing Applications.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Materials Engineering of Semiconductor Quantum Dots for Biosensing Applications./
Author:
Chern, Margaret.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2020,
Description:
211 p.
Notes:
Source: Dissertations Abstracts International, Volume: 80-12, Section: B.
Contained By:
Dissertations Abstracts International80-12B.
Subject:
Bioengineering. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13859040
ISBN:
9781392246061
Materials Engineering of Semiconductor Quantum Dots for Biosensing Applications.
Chern, Margaret.
Materials Engineering of Semiconductor Quantum Dots for Biosensing Applications.
- Ann Arbor : ProQuest Dissertations & Theses, 2020 - 211 p.
Source: Dissertations Abstracts International, Volume: 80-12, Section: B.
Thesis (Ph.D.)--Boston University, 2020.
This item is not available from ProQuest Dissertations & Theses.
The brightness and photostability of semiconductor quantum dots (QDs) has prompted the exploration of their use in a wide variety of fields. Several examples of QD-based biosensors have been reported but none have actually replaced their preexisting technologies. This work reveals the barriers hindering widespread use of QD based biosensors and examines how QDs can be engineered for improved utility in bioassay designs.The first portion of this project aims to improve Forster Resonance Energy Transfer (FRET) that use QDs as both the donor and acceptor. FRET-based sensors often use fluorescent dyes (FD) or proteins (FPs), but their photo- and chemical instability can be problematic. Contemporary QD-QD FRET systems suffer from unacceptably high background signal due to direct acceptor excitation. Materials engineering is used to create QD donors that are brighter than their QD acceptors to mitigate this effect. First, CdSe/xCdS/xZnS QDs of increasing shell thickness were synthesized and tested in a QD-fluorescent dye system to elucidate the effect of increased donor size on the performance of a FRET sensor. The optimal donors were medium-sized and 8 times brighter than commercially available QDs while retaining ~60% FRET efficiency. When used in a sensor, changes in sensor brightness were visible by eye. Moving towards QD-QD systems, a pH-based aggregation assay was used to test how QD heterostructures comprised of different semiconductor materials perform as FRET donors or acceptors. The fundamental principles uncovered are used to improve contemporary QD-QD FRET sensing and show that sensors can be designed to use color change as a visible, easy-to-decipher readout.Color change-based sensor output is further explored in an allosteric transcription factor-based small-molecule sensor that employs QDs as the sole fluorescent label. A highly modular design is presented that achieves a nanomolar concentration visual limit of detection. The ease of use, and fast, instrument-free readout of the sensor shows promise for its development into a fully integrated point-of-care device, endorsing the value of further developing QD-based in vitro biosensors for clinical or commercial translation.
ISBN: 9781392246061Subjects--Topical Terms:
657580
Bioengineering.
Subjects--Index Terms:
Fluorescence
Materials Engineering of Semiconductor Quantum Dots for Biosensing Applications.
LDR
:03482nmm a2200385 4500
001
2270046
005
20200921070609.5
008
220629s2020 ||||||||||||||||| ||eng d
020
$a
9781392246061
035
$a
(MiAaPQ)AAI13859040
035
$a
(MiAaPQ)bu:14637
035
$a
AAI13859040
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Chern, Margaret.
$3
3547414
245
1 0
$a
Materials Engineering of Semiconductor Quantum Dots for Biosensing Applications.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2020
300
$a
211 p.
500
$a
Source: Dissertations Abstracts International, Volume: 80-12, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Dennis, Allison M.
502
$a
Thesis (Ph.D.)--Boston University, 2020.
506
$a
This item is not available from ProQuest Dissertations & Theses.
506
$a
This item must not be sold to any third party vendors.
520
$a
The brightness and photostability of semiconductor quantum dots (QDs) has prompted the exploration of their use in a wide variety of fields. Several examples of QD-based biosensors have been reported but none have actually replaced their preexisting technologies. This work reveals the barriers hindering widespread use of QD based biosensors and examines how QDs can be engineered for improved utility in bioassay designs.The first portion of this project aims to improve Forster Resonance Energy Transfer (FRET) that use QDs as both the donor and acceptor. FRET-based sensors often use fluorescent dyes (FD) or proteins (FPs), but their photo- and chemical instability can be problematic. Contemporary QD-QD FRET systems suffer from unacceptably high background signal due to direct acceptor excitation. Materials engineering is used to create QD donors that are brighter than their QD acceptors to mitigate this effect. First, CdSe/xCdS/xZnS QDs of increasing shell thickness were synthesized and tested in a QD-fluorescent dye system to elucidate the effect of increased donor size on the performance of a FRET sensor. The optimal donors were medium-sized and 8 times brighter than commercially available QDs while retaining ~60% FRET efficiency. When used in a sensor, changes in sensor brightness were visible by eye. Moving towards QD-QD systems, a pH-based aggregation assay was used to test how QD heterostructures comprised of different semiconductor materials perform as FRET donors or acceptors. The fundamental principles uncovered are used to improve contemporary QD-QD FRET sensing and show that sensors can be designed to use color change as a visible, easy-to-decipher readout.Color change-based sensor output is further explored in an allosteric transcription factor-based small-molecule sensor that employs QDs as the sole fluorescent label. A highly modular design is presented that achieves a nanomolar concentration visual limit of detection. The ease of use, and fast, instrument-free readout of the sensor shows promise for its development into a fully integrated point-of-care device, endorsing the value of further developing QD-based in vitro biosensors for clinical or commercial translation.
590
$a
School code: 0017.
650
4
$a
Bioengineering.
$3
657580
650
4
$a
Nanoscience.
$3
587832
650
4
$a
Materials science.
$3
543314
653
$a
Fluorescence
653
$a
Fluorescent sensors
653
$a
Nanoparticles
690
$a
0202
690
$a
0565
690
$a
0794
710
2
$a
Boston University.
$b
Materials Science & Engineering ENG.
$3
3195090
773
0
$t
Dissertations Abstracts International
$g
80-12B.
790
$a
0017
791
$a
Ph.D.
792
$a
2020
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13859040
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9422280
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login