語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Structural and Functional Remodeling...
~
Salatino, Joseph William.
FindBook
Google Book
Amazon
博客來
Structural and Functional Remodeling of Neuronal Circuitry Surrounding Implanted Electrodes.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Structural and Functional Remodeling of Neuronal Circuitry Surrounding Implanted Electrodes./
作者:
Salatino, Joseph William.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2019,
面頁冊數:
173 p.
附註:
Source: Dissertations Abstracts International, Volume: 81-04, Section: B.
Contained By:
Dissertations Abstracts International81-04B.
標題:
Biomedical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=22619901
ISBN:
9781687903129
Structural and Functional Remodeling of Neuronal Circuitry Surrounding Implanted Electrodes.
Salatino, Joseph William.
Structural and Functional Remodeling of Neuronal Circuitry Surrounding Implanted Electrodes.
- Ann Arbor : ProQuest Dissertations & Theses, 2019 - 173 p.
Source: Dissertations Abstracts International, Volume: 81-04, Section: B.
Thesis (Ph.D.)--Michigan State University, 2019.
This item must not be sold to any third party vendors.
Microelectrode arrays designed to map and modulate neuronal circuitry have enabled greater understanding and treatment of neurological injury and disease. However, poor biological integration remains a significant barrier to the longevity and stability of electrodes implanted in the brain, where gliosis and neuronal loss are commonly attributed to instability and loss of signal over time. However, these metrics do not reliably predict signal loss, and device failure modes remain elusive. Here, this work provides fundamental insight into biological mechanisms that contribute to these failure modes, as well as develops genetic engineering strategies to improve the biointegration of brain implants.While signal-generating neurons have traditionally been considered the important target cells for implanted electrodes, it has become increasingly appreciated that glia remodel the structure and function of neuronal networks following injury, where recent work has uncovered mechanisms relevant to the injuries and ensuing gliosis caused by the implantation of chronic devices. Chapter 2 disseminates important considerations for glial reactivity on device performance and provides a framework for topics explored in subsequent Chapters. Although decades of work has demonstrated that cortical injury generates long-term remodeling of excitatory/inhibitory synapses (the connections which facilitate the propagation of information between neurons) and ion channels (the transmembrane proteins responsible for generating neuronal signals), these mechanisms have not been investigated around implanted arrays; however, the consequences of these events hold significant implications for the long-term recording stability of implanted devices. Chapter 3 reveals novel changes in both excitatory and inhibitory synaptic circuitry surrounding implanted microelectrodes, where early elevations in excitatory synapses are followed by a shift to inhibitory tone in the chronic setting. A novel subtype of glia is also identified local to the device interface. Chapter 4 reveals a novel relationship between electrophysiological recordings and ion channel expression surrounding implanted arrays over time, where a loss of sodium channel expression and gain in potassium channel expression corresponds with a loss of recorded signals over time. Together, this work supports a trend from hyper- to hypo-excitability, which temporally coincides with signal variability and loss observed with chronic devices.The previous chapters provide fundamental insight into major circuit changes at the interface that inform both basic-science knowledge and new strategies for improving the biointegration of brain implants. We are developing new approaches to reveal the mechanistic role of these factors in affecting recorded signals over time. Chapter 5 covers ongoing work that includes the development and validation of innovative strategies to deliver genetic material at the interface in vivo to yield entirely new avenues of research with opportunities to regulate gene expression and/or introduce new genetic material to rewire the interfacial network. Future directions are discussed with opportunities to unmask key circuit-remodeling effects that impair device performance as well as inform the seamless integration of brain implants.
ISBN: 9781687903129Subjects--Topical Terms:
535387
Biomedical engineering.
Subjects--Index Terms:
Brain-machine interfaces
Structural and Functional Remodeling of Neuronal Circuitry Surrounding Implanted Electrodes.
LDR
:04547nmm a2200385 4500
001
2268003
005
20200810100219.5
008
220629s2019 ||||||||||||||||| ||eng d
020
$a
9781687903129
035
$a
(MiAaPQ)AAI22619901
035
$a
AAI22619901
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Salatino, Joseph William.
$3
3545256
245
1 0
$a
Structural and Functional Remodeling of Neuronal Circuitry Surrounding Implanted Electrodes.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2019
300
$a
173 p.
500
$a
Source: Dissertations Abstracts International, Volume: 81-04, Section: B.
500
$a
Advisor: Purcell, Erin.
502
$a
Thesis (Ph.D.)--Michigan State University, 2019.
506
$a
This item must not be sold to any third party vendors.
520
$a
Microelectrode arrays designed to map and modulate neuronal circuitry have enabled greater understanding and treatment of neurological injury and disease. However, poor biological integration remains a significant barrier to the longevity and stability of electrodes implanted in the brain, where gliosis and neuronal loss are commonly attributed to instability and loss of signal over time. However, these metrics do not reliably predict signal loss, and device failure modes remain elusive. Here, this work provides fundamental insight into biological mechanisms that contribute to these failure modes, as well as develops genetic engineering strategies to improve the biointegration of brain implants.While signal-generating neurons have traditionally been considered the important target cells for implanted electrodes, it has become increasingly appreciated that glia remodel the structure and function of neuronal networks following injury, where recent work has uncovered mechanisms relevant to the injuries and ensuing gliosis caused by the implantation of chronic devices. Chapter 2 disseminates important considerations for glial reactivity on device performance and provides a framework for topics explored in subsequent Chapters. Although decades of work has demonstrated that cortical injury generates long-term remodeling of excitatory/inhibitory synapses (the connections which facilitate the propagation of information between neurons) and ion channels (the transmembrane proteins responsible for generating neuronal signals), these mechanisms have not been investigated around implanted arrays; however, the consequences of these events hold significant implications for the long-term recording stability of implanted devices. Chapter 3 reveals novel changes in both excitatory and inhibitory synaptic circuitry surrounding implanted microelectrodes, where early elevations in excitatory synapses are followed by a shift to inhibitory tone in the chronic setting. A novel subtype of glia is also identified local to the device interface. Chapter 4 reveals a novel relationship between electrophysiological recordings and ion channel expression surrounding implanted arrays over time, where a loss of sodium channel expression and gain in potassium channel expression corresponds with a loss of recorded signals over time. Together, this work supports a trend from hyper- to hypo-excitability, which temporally coincides with signal variability and loss observed with chronic devices.The previous chapters provide fundamental insight into major circuit changes at the interface that inform both basic-science knowledge and new strategies for improving the biointegration of brain implants. We are developing new approaches to reveal the mechanistic role of these factors in affecting recorded signals over time. Chapter 5 covers ongoing work that includes the development and validation of innovative strategies to deliver genetic material at the interface in vivo to yield entirely new avenues of research with opportunities to regulate gene expression and/or introduce new genetic material to rewire the interfacial network. Future directions are discussed with opportunities to unmask key circuit-remodeling effects that impair device performance as well as inform the seamless integration of brain implants.
590
$a
School code: 0128.
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Bioengineering.
$3
657580
650
4
$a
Neurosciences.
$3
588700
653
$a
Brain-machine interfaces
653
$a
Microelectrode arrays
653
$a
Neural engineering
653
$a
Neuroprostheses
653
$a
Plasticity
653
$a
Tissue response
690
$a
0541
690
$a
0202
690
$a
0317
710
2
$a
Michigan State University.
$b
Biomedical Engineering - Doctor of Philosophy.
$3
3545257
773
0
$t
Dissertations Abstracts International
$g
81-04B.
790
$a
0128
791
$a
Ph.D.
792
$a
2019
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=22619901
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9420237
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入