Characterization of Impedance Proper...
~
Hnat, Andrew Thomas.
Linked to FindBook
Google Book
Amazon
博客來
Characterization of Impedance Properties of A Conductive Electrospun Polymer Biopotential Electrode with Porous Fiber Arrays.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Characterization of Impedance Properties of A Conductive Electrospun Polymer Biopotential Electrode with Porous Fiber Arrays./
Author:
Hnat, Andrew Thomas.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2019,
Description:
108 p.
Notes:
Source: Masters Abstracts International, Volume: 81-04.
Contained By:
Masters Abstracts International81-04.
Subject:
Mechanical engineering. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13899469
ISBN:
9781085667463
Characterization of Impedance Properties of A Conductive Electrospun Polymer Biopotential Electrode with Porous Fiber Arrays.
Hnat, Andrew Thomas.
Characterization of Impedance Properties of A Conductive Electrospun Polymer Biopotential Electrode with Porous Fiber Arrays.
- Ann Arbor : ProQuest Dissertations & Theses, 2019 - 108 p.
Source: Masters Abstracts International, Volume: 81-04.
Thesis (M.S.)--San Diego State University, 2019.
This item must not be sold to any third party vendors.
EEG and ECG recordings are two of the most widely-used diagnostic tests in the medical field. One of the most commonly-used biopotential electrode in EEG and ECG testing is a silver-silver chloride electrode that attaches to the skin via an adhesive gel embedded into the electrode. This electrode transduces brainwave and cardiac signals through the skin very well, however, skin preparation, such as abrasion, and hair removal is needed in order to achieve an acceptable skin connection. This fact makes applying many electrodes to the skin an arduous and painful process. Dry, spiked electrodes are also available, however, they too suffer from drawbacks relating to pain and discomfort during use. The goal of this study was to test and compare two prototype semi-wet electrodes developed in-lab that utilized non-conventional electrode materials. The first prototype utilizes a dry, spiked electrode covered by an electrolyte gel-filled conductive 3D printed polymer cap. The second prototype is a semi-wet polymer fiber core electrode fabricated through a process known as electro spinning. Electrolyte gel is impregnated into the fiber core of this electrode to enhance the amount of ion exchange for biopotential signal transduction resulting from the high surface area the fiber core possesses. A series of trials were performed to analyze the impedance of each electrode over a range of frequencies using an Agilent 4294a impedance analyzer. Impedance analysis measures how well an electrode can transduce a signal with the least amount of noise possible, which in-turn gives the clearest EEG and ECG readings. Impedance and signal transduction have an inverse relationship. The lower the impedance, the clearer the signal. The impedance analysis trials among thirteen different electrode cases revealed that the two hybrid prototype semi-wet electrodes performed better than both the dry electrode and the adhesive electrode on a consistent basis. The first prototype electrode exhibited circuit impedance improvements of approximately 12%, and the second prototype electrode showed improvements as high as 48%. The promising results of the two in-lab developed electrodes have shown strong potential for a new design and material category of biopotential sensors to be further researched and explored.
ISBN: 9781085667463Subjects--Topical Terms:
649730
Mechanical engineering.
Characterization of Impedance Properties of A Conductive Electrospun Polymer Biopotential Electrode with Porous Fiber Arrays.
LDR
:03375nmm a2200337 4500
001
2267978
005
20200810100212.5
008
220629s2019 ||||||||||||||||| ||eng d
020
$a
9781085667463
035
$a
(MiAaPQ)AAI13899469
035
$a
AAI13899469
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Hnat, Andrew Thomas.
$3
3545230
245
1 0
$a
Characterization of Impedance Properties of A Conductive Electrospun Polymer Biopotential Electrode with Porous Fiber Arrays.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2019
300
$a
108 p.
500
$a
Source: Masters Abstracts International, Volume: 81-04.
500
$a
Advisor: Moon, Kee S.
502
$a
Thesis (M.S.)--San Diego State University, 2019.
506
$a
This item must not be sold to any third party vendors.
520
$a
EEG and ECG recordings are two of the most widely-used diagnostic tests in the medical field. One of the most commonly-used biopotential electrode in EEG and ECG testing is a silver-silver chloride electrode that attaches to the skin via an adhesive gel embedded into the electrode. This electrode transduces brainwave and cardiac signals through the skin very well, however, skin preparation, such as abrasion, and hair removal is needed in order to achieve an acceptable skin connection. This fact makes applying many electrodes to the skin an arduous and painful process. Dry, spiked electrodes are also available, however, they too suffer from drawbacks relating to pain and discomfort during use. The goal of this study was to test and compare two prototype semi-wet electrodes developed in-lab that utilized non-conventional electrode materials. The first prototype utilizes a dry, spiked electrode covered by an electrolyte gel-filled conductive 3D printed polymer cap. The second prototype is a semi-wet polymer fiber core electrode fabricated through a process known as electro spinning. Electrolyte gel is impregnated into the fiber core of this electrode to enhance the amount of ion exchange for biopotential signal transduction resulting from the high surface area the fiber core possesses. A series of trials were performed to analyze the impedance of each electrode over a range of frequencies using an Agilent 4294a impedance analyzer. Impedance analysis measures how well an electrode can transduce a signal with the least amount of noise possible, which in-turn gives the clearest EEG and ECG readings. Impedance and signal transduction have an inverse relationship. The lower the impedance, the clearer the signal. The impedance analysis trials among thirteen different electrode cases revealed that the two hybrid prototype semi-wet electrodes performed better than both the dry electrode and the adhesive electrode on a consistent basis. The first prototype electrode exhibited circuit impedance improvements of approximately 12%, and the second prototype electrode showed improvements as high as 48%. The promising results of the two in-lab developed electrodes have shown strong potential for a new design and material category of biopotential sensors to be further researched and explored.
590
$a
School code: 0220.
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Polymer chemistry.
$3
3173488
650
4
$a
Nanotechnology.
$3
526235
650
4
$a
Nanoscience.
$3
587832
690
$a
0548
690
$a
0565
690
$a
0541
690
$a
0652
690
$a
0495
710
2
$a
San Diego State University.
$b
Mechanical Engineering.
$3
2103928
773
0
$t
Masters Abstracts International
$g
81-04.
790
$a
0220
791
$a
M.S.
792
$a
2019
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13899469
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9420212
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login