語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
New Implementations of Phase-Contras...
~
Ba, Cong.
FindBook
Google Book
Amazon
博客來
New Implementations of Phase-Contrast Imaging.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
New Implementations of Phase-Contrast Imaging./
作者:
Ba, Cong.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2019,
面頁冊數:
137 p.
附註:
Source: Dissertations Abstracts International, Volume: 80-09, Section: B.
Contained By:
Dissertations Abstracts International80-09B.
標題:
Biomedical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13426994
ISBN:
9780438972896
New Implementations of Phase-Contrast Imaging.
Ba, Cong.
New Implementations of Phase-Contrast Imaging.
- Ann Arbor : ProQuest Dissertations & Theses, 2019 - 137 p.
Source: Dissertations Abstracts International, Volume: 80-09, Section: B.
Thesis (Ph.D.)--Boston University, 2019.
This item must not be added to any third party search indexes.
Phase-contrast imaging is a method of imaging widely used in biomedical research and applications. It is a label-free method that exploits intrinsic differences in the refractive index of different tissues to differentiate between biological structures under analysis. The basic principle of phase-contrast imaging has inspired a lot of implementations that are suited for different applications. This thesis explores multiple novel implementations of phase-contrast imaging in the following order. 1, We combined scanning Oblique Back-illumination Microscope (sOBM) and confocal microscope to produce phase and fluorescence contrast images in an endomicroscopy configuration. This dual-modality design provides co-registered, complementary labeled and unlabeled contrast of the sample. We further miniaturized the probe by dispensing the two optical fibers in our old design. And we presented proof of principle demonstrations with ex-vivo mouse colon tissue. 2, Then we explored sOBM-based phase and amplitude contrast imaging under different wavelengths. Hyperspectral imaging is achieved by multiplexing a wide-range supercontinuum laser with a Michaelson interferometer (similar to Fourier transform spectroscopy). It features simultaneous acquisition of hyperspectral phase and amplitude images with arbitrarily thick scattering biological samples. Proof-of-principle demonstrations are presented with chorioallantoic membrane of a chick embryo, illustrating the possibility of high-resolution hemodynamics imaging in thick tissue. 3, We focused on increasing the throughput of flow cytometry with principle of phase-contrast imaging and compressive sensing. By utilizing the linearity of scattered patterns under partially coherent illumination, our cytometer can detect multiple objects in the same field of view. By utilizing an optimized matched filter on pupil plane, it also provides increased information capacity of each measurement without sacrificing speed. We demonstrated a throughput of over 10,000 particles/s with accuracy over 91% in our results. 4, A fourth part, which describes the principle and preliminary results of a computational fluorescence endomicroscope is also included. It uses a numerical method to achieve sectioning effect and renders a pseudo-3D image stack with a single shot. The results are compared with true-3D image stack acquired with a confocal microscope.
ISBN: 9780438972896Subjects--Topical Terms:
535387
Biomedical engineering.
New Implementations of Phase-Contrast Imaging.
LDR
:03537nmm a2200349 4500
001
2263156
005
20200214113159.5
008
220629s2019 ||||||||||||||||| ||eng d
020
$a
9780438972896
035
$a
(MiAaPQ)AAI13426994
035
$a
(MiAaPQ)bu:14352
035
$a
AAI13426994
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Ba, Cong.
$3
3540240
245
1 0
$a
New Implementations of Phase-Contrast Imaging.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2019
300
$a
137 p.
500
$a
Source: Dissertations Abstracts International, Volume: 80-09, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Mertz, Jerome C.
502
$a
Thesis (Ph.D.)--Boston University, 2019.
506
$a
This item must not be added to any third party search indexes.
506
$a
This item must not be sold to any third party vendors.
520
$a
Phase-contrast imaging is a method of imaging widely used in biomedical research and applications. It is a label-free method that exploits intrinsic differences in the refractive index of different tissues to differentiate between biological structures under analysis. The basic principle of phase-contrast imaging has inspired a lot of implementations that are suited for different applications. This thesis explores multiple novel implementations of phase-contrast imaging in the following order. 1, We combined scanning Oblique Back-illumination Microscope (sOBM) and confocal microscope to produce phase and fluorescence contrast images in an endomicroscopy configuration. This dual-modality design provides co-registered, complementary labeled and unlabeled contrast of the sample. We further miniaturized the probe by dispensing the two optical fibers in our old design. And we presented proof of principle demonstrations with ex-vivo mouse colon tissue. 2, Then we explored sOBM-based phase and amplitude contrast imaging under different wavelengths. Hyperspectral imaging is achieved by multiplexing a wide-range supercontinuum laser with a Michaelson interferometer (similar to Fourier transform spectroscopy). It features simultaneous acquisition of hyperspectral phase and amplitude images with arbitrarily thick scattering biological samples. Proof-of-principle demonstrations are presented with chorioallantoic membrane of a chick embryo, illustrating the possibility of high-resolution hemodynamics imaging in thick tissue. 3, We focused on increasing the throughput of flow cytometry with principle of phase-contrast imaging and compressive sensing. By utilizing the linearity of scattered patterns under partially coherent illumination, our cytometer can detect multiple objects in the same field of view. By utilizing an optimized matched filter on pupil plane, it also provides increased information capacity of each measurement without sacrificing speed. We demonstrated a throughput of over 10,000 particles/s with accuracy over 91% in our results. 4, A fourth part, which describes the principle and preliminary results of a computational fluorescence endomicroscope is also included. It uses a numerical method to achieve sectioning effect and renders a pseudo-3D image stack with a single shot. The results are compared with true-3D image stack acquired with a confocal microscope.
590
$a
School code: 0017.
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Optics.
$3
517925
690
$a
0541
690
$a
0544
690
$a
0752
710
2
$a
Boston University.
$b
Biomedical Engineering ENG.
$3
3193140
773
0
$t
Dissertations Abstracts International
$g
80-09B.
790
$a
0017
791
$a
Ph.D.
792
$a
2019
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13426994
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9415390
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入