語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Imaging of trabecular microfracture ...
~
Bahk, Yong-Whee.
FindBook
Google Book
Amazon
博客來
Imaging of trabecular microfracture and bone marrow edema and hemorrhage
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Imaging of trabecular microfracture and bone marrow edema and hemorrhage/ by Yong-Whee Bahk.
作者:
Bahk, Yong-Whee.
出版者:
Singapore :Springer Singapore : : 2020.,
面頁冊數:
xvii, 146 p. :ill., digital ;24 cm.
內容註:
1. Introduction -- 2. Pinhole Bone Scanning -- 3. Gamma Correction -- 4. Technical Processing of Gamma Correction -- 5. Gamma Correction Pinhole Bone Scan -- 6. Experimental Gamma Correction 99mTc-HDP Pinhole Bone Scan, Diagnosis of Trabecular Microfracture in Young Rats -- 7. Preoperative Confirmatory Imaging Diagnosis of Femoral Neck Fracture -- 8. Gamma Correction Pinhole Scan of Surgical Specimen and Correlation of Thereof and H&E Stain Findings for Histological Identification -- 9. Hematoxylin-Eosin Stain of Calcifying Calluses in Trabecular Microfractures -- 10. Identification of Trabecular Microcalluses in GCPBS and H&E Stain -- 11. Quantitation of 99mTc-HDP Uptake in Microcallus Using Pixelized Method -- 12. Quantitation of Gamma Correction Pinhole Bone Scan and H&E Stain -- 13. Reciprocal Correlation of Shapes of Tracer Uptake and Findings of Surgical Specimen, GCPBS and H&E Stain -- 14. Morphobiochemical Diagnosis of Acute Trabecular Microcallus Using Gamma Correction 99mTc-HDP Pinhole Bone Scan with Histological Verification -- 15. Preoperative Diagnosis by Radiography and 99mTcHDP Pinhole Bone Scan -- 16. Surgical Specimens from Human Subjects -- 17. Preoperative Diagnosis by Radiography and 99mTcHDP Pinhole Bone Scan -- 18. Gamma Correction Pinhole Scanof Surgical Specimen and Correlation of Thereof and H&E Stain Findings for Histological Identification -- 19. Gamma Correction Pinhole Bone Scan -- 20. Identification of Trabecular Microfractures in GCPBS and H&E Stain -- 21. Quantification of Micro-Fracture Tracer Uptake Using Pixelized Measurement -- 22. Overall Considerations -- 23. Precise Differntial Diagnosis of Acute Bone Marrow Edema and Hemorrhage and Trabecular Microfracture Using Nave and Gamma Correction Pinhole Bone Scans, NIH ImageJ Densitometry, and Pixelized -- 24. Micofracture Measurement -- 25. Introduction -- 26. Clinical Materials -- 27. Techniques of Seriated Nave and Gamma Correction Pinhole Bone Scanning and Reference Conventional Radiography and Corroborative Coronal FS T2 weighted MRI -- 28. NIH ImageJ Densitometry of 99mTc-HDP Uptake Intensity Measurement in Bone Marrow Edema and Hemorrhage and Trabecular Microfracture on Seriated Naive and Gamma Correction Pinhole Bone Scans -- 29. Mathematic Measurement of Trabecular Microfracture Size with Unsuppressed 99mTc-HDP uptake -- 30. Differential 99mTc-HDP Uptake Intensity Measurement of Bone Marrow Edema and Hemorrhage Using ImageJ Densitometry -- 31. Histopathological Validation -- 32. Differential Diagnosis of Bone Marrow Edema and Hemorrhage Using ImageJ Densitometry -- 33. Innocuousness of Bone Marrow Edema to Intact Trabecula on Nave Pinhole Scan Showing Mild Tracer Uptake Which is Suppressed -- 34. Differential Image J Densitometry Intensity Values of 99mTc-HDP Uptake in Bone Marrow Edema and Hemorrhage and Trabecular Microfracture -- 35. Fractured Trabeculae with Unsuppressed Enhanced Tracer Uptake -- 36. Innocuousness of Edema to Intact Trabecula and Injuriousness of Hemorrhage to Already Broken Trabecula -- 37. H&E Stain Validation of Additive Bone Marrow Hemorrhage Which Injures Already -- 38. NIH Image J Densitometric Analysis of an Old MR Image of Histologically Proven "Edemalike"Bone Marrow Change in Knee -- 39. Discussion -- 40. Summary and Conclusions.
Contained By:
Springer Nature eBook
標題:
Fractures - Imaging. -
電子資源:
https://doi.org/10.1007/978-981-15-4466-8
ISBN:
9789811544668
Imaging of trabecular microfracture and bone marrow edema and hemorrhage
Bahk, Yong-Whee.
Imaging of trabecular microfracture and bone marrow edema and hemorrhage
[electronic resource] /by Yong-Whee Bahk. - Singapore :Springer Singapore :2020. - xvii, 146 p. :ill., digital ;24 cm.
1. Introduction -- 2. Pinhole Bone Scanning -- 3. Gamma Correction -- 4. Technical Processing of Gamma Correction -- 5. Gamma Correction Pinhole Bone Scan -- 6. Experimental Gamma Correction 99mTc-HDP Pinhole Bone Scan, Diagnosis of Trabecular Microfracture in Young Rats -- 7. Preoperative Confirmatory Imaging Diagnosis of Femoral Neck Fracture -- 8. Gamma Correction Pinhole Scan of Surgical Specimen and Correlation of Thereof and H&E Stain Findings for Histological Identification -- 9. Hematoxylin-Eosin Stain of Calcifying Calluses in Trabecular Microfractures -- 10. Identification of Trabecular Microcalluses in GCPBS and H&E Stain -- 11. Quantitation of 99mTc-HDP Uptake in Microcallus Using Pixelized Method -- 12. Quantitation of Gamma Correction Pinhole Bone Scan and H&E Stain -- 13. Reciprocal Correlation of Shapes of Tracer Uptake and Findings of Surgical Specimen, GCPBS and H&E Stain -- 14. Morphobiochemical Diagnosis of Acute Trabecular Microcallus Using Gamma Correction 99mTc-HDP Pinhole Bone Scan with Histological Verification -- 15. Preoperative Diagnosis by Radiography and 99mTcHDP Pinhole Bone Scan -- 16. Surgical Specimens from Human Subjects -- 17. Preoperative Diagnosis by Radiography and 99mTcHDP Pinhole Bone Scan -- 18. Gamma Correction Pinhole Scanof Surgical Specimen and Correlation of Thereof and H&E Stain Findings for Histological Identification -- 19. Gamma Correction Pinhole Bone Scan -- 20. Identification of Trabecular Microfractures in GCPBS and H&E Stain -- 21. Quantification of Micro-Fracture Tracer Uptake Using Pixelized Measurement -- 22. Overall Considerations -- 23. Precise Differntial Diagnosis of Acute Bone Marrow Edema and Hemorrhage and Trabecular Microfracture Using Nave and Gamma Correction Pinhole Bone Scans, NIH ImageJ Densitometry, and Pixelized -- 24. Micofracture Measurement -- 25. Introduction -- 26. Clinical Materials -- 27. Techniques of Seriated Nave and Gamma Correction Pinhole Bone Scanning and Reference Conventional Radiography and Corroborative Coronal FS T2 weighted MRI -- 28. NIH ImageJ Densitometry of 99mTc-HDP Uptake Intensity Measurement in Bone Marrow Edema and Hemorrhage and Trabecular Microfracture on Seriated Naive and Gamma Correction Pinhole Bone Scans -- 29. Mathematic Measurement of Trabecular Microfracture Size with Unsuppressed 99mTc-HDP uptake -- 30. Differential 99mTc-HDP Uptake Intensity Measurement of Bone Marrow Edema and Hemorrhage Using ImageJ Densitometry -- 31. Histopathological Validation -- 32. Differential Diagnosis of Bone Marrow Edema and Hemorrhage Using ImageJ Densitometry -- 33. Innocuousness of Bone Marrow Edema to Intact Trabecula on Nave Pinhole Scan Showing Mild Tracer Uptake Which is Suppressed -- 34. Differential Image J Densitometry Intensity Values of 99mTc-HDP Uptake in Bone Marrow Edema and Hemorrhage and Trabecular Microfracture -- 35. Fractured Trabeculae with Unsuppressed Enhanced Tracer Uptake -- 36. Innocuousness of Edema to Intact Trabecula and Injuriousness of Hemorrhage to Already Broken Trabecula -- 37. H&E Stain Validation of Additive Bone Marrow Hemorrhage Which Injures Already -- 38. NIH Image J Densitometric Analysis of an Old MR Image of Histologically Proven "Edemalike"Bone Marrow Change in Knee -- 39. Discussion -- 40. Summary and Conclusions.
This excellently illustrated monograph summarizes the updated fresh information on the theoretical, practical, and rapidly extended facets of gamma correction 99mTc-hydroxymethylene diphosphonate pinhole bone scan (99mTc-GCPBS) to MRI, CR, and MDCT. Basically, 99mTc-GCPBS is able to precisely visualize and quantitate callused trabecular microfracture (CTMF) which is as little as 200 um in size. The extended gamma correction images can very neatly demonstrate CTMF on MRI, conventional radiography (CR), and multidetector computed tomography (MDCT) Whenever appropriate, histological correlation is provided in conjunction with fine gamma corrected images. In this setting, ACDSee 10 gamma correction MRI and CR have been found to offer a highly useful option that deserves wider clinical interest. In practice, gamma correction MRI, CR, and MDCT can distinctly visualize CTMF so that CTMF can be precisely measured simply using an optic lens. By comparison, the naive MRI, for example, shows CTMF which measures as big as 2 mm in size. Furthermore, 99mTc-GCPBS can now differentiate bone marrow edema from hemorrhage using the visuospatial mathematic method, which includes the ImageJ of the NIH.
ISBN: 9789811544668
Standard No.: 10.1007/978-981-15-4466-8doiSubjects--Topical Terms:
3526073
Fractures
--Imaging.
LC Class. No.: RD101
Dewey Class. No.: 617.15
Imaging of trabecular microfracture and bone marrow edema and hemorrhage
LDR
:05483nmm a2200325 a 4500
001
2256067
003
DE-He213
005
20201229101752.0
006
m d
007
cr nn 008maaau
008
220420s2020 si s 0 eng d
020
$a
9789811544668
$q
(electronic bk.)
020
$a
9789811544651
$q
(paper)
024
7
$a
10.1007/978-981-15-4466-8
$2
doi
035
$a
978-981-15-4466-8
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
RD101
072
7
$a
MMN
$2
bicssc
072
7
$a
MED080000
$2
bisacsh
072
7
$a
MKR
$2
thema
082
0 4
$a
617.15
$2
23
090
$a
RD101
$b
.B151 2020
100
1
$a
Bahk, Yong-Whee.
$3
3259243
245
1 0
$a
Imaging of trabecular microfracture and bone marrow edema and hemorrhage
$h
[electronic resource] /
$c
by Yong-Whee Bahk.
260
$a
Singapore :
$b
Springer Singapore :
$b
Imprint: Springer,
$c
2020.
300
$a
xvii, 146 p. :
$b
ill., digital ;
$c
24 cm.
505
0
$a
1. Introduction -- 2. Pinhole Bone Scanning -- 3. Gamma Correction -- 4. Technical Processing of Gamma Correction -- 5. Gamma Correction Pinhole Bone Scan -- 6. Experimental Gamma Correction 99mTc-HDP Pinhole Bone Scan, Diagnosis of Trabecular Microfracture in Young Rats -- 7. Preoperative Confirmatory Imaging Diagnosis of Femoral Neck Fracture -- 8. Gamma Correction Pinhole Scan of Surgical Specimen and Correlation of Thereof and H&E Stain Findings for Histological Identification -- 9. Hematoxylin-Eosin Stain of Calcifying Calluses in Trabecular Microfractures -- 10. Identification of Trabecular Microcalluses in GCPBS and H&E Stain -- 11. Quantitation of 99mTc-HDP Uptake in Microcallus Using Pixelized Method -- 12. Quantitation of Gamma Correction Pinhole Bone Scan and H&E Stain -- 13. Reciprocal Correlation of Shapes of Tracer Uptake and Findings of Surgical Specimen, GCPBS and H&E Stain -- 14. Morphobiochemical Diagnosis of Acute Trabecular Microcallus Using Gamma Correction 99mTc-HDP Pinhole Bone Scan with Histological Verification -- 15. Preoperative Diagnosis by Radiography and 99mTcHDP Pinhole Bone Scan -- 16. Surgical Specimens from Human Subjects -- 17. Preoperative Diagnosis by Radiography and 99mTcHDP Pinhole Bone Scan -- 18. Gamma Correction Pinhole Scanof Surgical Specimen and Correlation of Thereof and H&E Stain Findings for Histological Identification -- 19. Gamma Correction Pinhole Bone Scan -- 20. Identification of Trabecular Microfractures in GCPBS and H&E Stain -- 21. Quantification of Micro-Fracture Tracer Uptake Using Pixelized Measurement -- 22. Overall Considerations -- 23. Precise Differntial Diagnosis of Acute Bone Marrow Edema and Hemorrhage and Trabecular Microfracture Using Nave and Gamma Correction Pinhole Bone Scans, NIH ImageJ Densitometry, and Pixelized -- 24. Micofracture Measurement -- 25. Introduction -- 26. Clinical Materials -- 27. Techniques of Seriated Nave and Gamma Correction Pinhole Bone Scanning and Reference Conventional Radiography and Corroborative Coronal FS T2 weighted MRI -- 28. NIH ImageJ Densitometry of 99mTc-HDP Uptake Intensity Measurement in Bone Marrow Edema and Hemorrhage and Trabecular Microfracture on Seriated Naive and Gamma Correction Pinhole Bone Scans -- 29. Mathematic Measurement of Trabecular Microfracture Size with Unsuppressed 99mTc-HDP uptake -- 30. Differential 99mTc-HDP Uptake Intensity Measurement of Bone Marrow Edema and Hemorrhage Using ImageJ Densitometry -- 31. Histopathological Validation -- 32. Differential Diagnosis of Bone Marrow Edema and Hemorrhage Using ImageJ Densitometry -- 33. Innocuousness of Bone Marrow Edema to Intact Trabecula on Nave Pinhole Scan Showing Mild Tracer Uptake Which is Suppressed -- 34. Differential Image J Densitometry Intensity Values of 99mTc-HDP Uptake in Bone Marrow Edema and Hemorrhage and Trabecular Microfracture -- 35. Fractured Trabeculae with Unsuppressed Enhanced Tracer Uptake -- 36. Innocuousness of Edema to Intact Trabecula and Injuriousness of Hemorrhage to Already Broken Trabecula -- 37. H&E Stain Validation of Additive Bone Marrow Hemorrhage Which Injures Already -- 38. NIH Image J Densitometric Analysis of an Old MR Image of Histologically Proven "Edemalike"Bone Marrow Change in Knee -- 39. Discussion -- 40. Summary and Conclusions.
520
$a
This excellently illustrated monograph summarizes the updated fresh information on the theoretical, practical, and rapidly extended facets of gamma correction 99mTc-hydroxymethylene diphosphonate pinhole bone scan (99mTc-GCPBS) to MRI, CR, and MDCT. Basically, 99mTc-GCPBS is able to precisely visualize and quantitate callused trabecular microfracture (CTMF) which is as little as 200 um in size. The extended gamma correction images can very neatly demonstrate CTMF on MRI, conventional radiography (CR), and multidetector computed tomography (MDCT) Whenever appropriate, histological correlation is provided in conjunction with fine gamma corrected images. In this setting, ACDSee 10 gamma correction MRI and CR have been found to offer a highly useful option that deserves wider clinical interest. In practice, gamma correction MRI, CR, and MDCT can distinctly visualize CTMF so that CTMF can be precisely measured simply using an optic lens. By comparison, the naive MRI, for example, shows CTMF which measures as big as 2 mm in size. Furthermore, 99mTc-GCPBS can now differentiate bone marrow edema from hemorrhage using the visuospatial mathematic method, which includes the ImageJ of the NIH.
650
0
$a
Fractures
$x
Imaging.
$3
3526073
650
1 4
$a
Nuclear Medicine.
$3
823642
710
2
$a
SpringerLink (Online service)
$3
836513
773
0
$t
Springer Nature eBook
856
4 0
$u
https://doi.org/10.1007/978-981-15-4466-8
950
$a
Medicine (SpringerNature-11650)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9411703
電子資源
11.線上閱覽_V
電子書
EB RD101
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入