語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Development, Validation, and Transla...
~
O'Connell, Dylan Patrick.
FindBook
Google Book
Amazon
博客來
Development, Validation, and Translation of a Respiratory Motion Model-Based 4DCT Technique for Use as a Clinical Protocol for Radiation Therapy Treatment Planning.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Development, Validation, and Translation of a Respiratory Motion Model-Based 4DCT Technique for Use as a Clinical Protocol for Radiation Therapy Treatment Planning./
作者:
O'Connell, Dylan Patrick.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2018,
面頁冊數:
143 p.
附註:
Source: Dissertations Abstracts International, Volume: 79-12, Section: B.
Contained By:
Dissertations Abstracts International79-12B.
標題:
Medical imaging. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10825384
ISBN:
9780438002296
Development, Validation, and Translation of a Respiratory Motion Model-Based 4DCT Technique for Use as a Clinical Protocol for Radiation Therapy Treatment Planning.
O'Connell, Dylan Patrick.
Development, Validation, and Translation of a Respiratory Motion Model-Based 4DCT Technique for Use as a Clinical Protocol for Radiation Therapy Treatment Planning.
- Ann Arbor : ProQuest Dissertations & Theses, 2018 - 143 p.
Source: Dissertations Abstracts International, Volume: 79-12, Section: B.
Thesis (Ph.D.)--University of California, Los Angeles, 2018.
This item must not be added to any third party search indexes.
Breathing motion in radiotherapy is commonly managed with four-dimensional computed tomography (4DCT). 4DCT datasets consist of multiple breathing-gated images that display motion of the subject's anatomy over a breathing period. Commercial 4DCT protocols are susceptible to image artifacts when the subject breathes irregularly. Unlike commercial protocols, model-based 4DCT techniques describe a correspondence between tissue motion and an external signal used as a surrogate for respiratory phase. One such technique, termed '5DCT,' uses free-breathing fast helical acquisition and characterizes lung tissue motion as function of five degrees of freedom: x,y, and z position in a reference geometry, breathing amplitude, and breathing rate. The overarching goal of this dissertation is to develop the 5DCT technique for clinical use. A validation study was conducted involving comparing 5DCT images to commercial 4DCT using an animal model. Reproducible and periodic breathing patterns were achieved through mechanical ventilation and image similarity was quantified using landmark displacement. Differences in measured tumor motion between 5DCT and commercial 4DCT were examined in a cohort of 20 lung cancer patients. Solutions for the unique challenges of using model model-based techniques clinically, such as appropriate amplitude interval selection and presentation of a quantitative error map, were developed. A quality management program was developed to ensure the safety of the protocol using risk analysis methods such as process mapping and failure modes and effects analysis. In addition, safety of the in-house software required to implement the technique was managed through use cases and quantitative, testable safety requirements. The physiological significance of the 5D model parameters was investigated, particularly their dependence on breathing rate during acquisition. It was shown that the model parameter relating tissue motion to breathing amplitude was largely invariant with breathing rate during acquisition. A prospective scanning method was developed to reduce the number of fast helical scans, and associated imaging dose, necessary to perform 5DCT while maintaining motion modeling accuracy. A simulation study was conducted using patient breathing traces, and the results demonstrated that adequate sampling of the respiratory cycle could be achieved using six scans, compared to the previously published protocol that employs twenty-five.
ISBN: 9780438002296Subjects--Topical Terms:
3172799
Medical imaging.
Development, Validation, and Translation of a Respiratory Motion Model-Based 4DCT Technique for Use as a Clinical Protocol for Radiation Therapy Treatment Planning.
LDR
:03717nmm a2200325 4500
001
2210432
005
20191121124220.5
008
201008s2018 ||||||||||||||||| ||eng d
020
$a
9780438002296
035
$a
(MiAaPQ)AAI10825384
035
$a
(MiAaPQ)ucla:16784
035
$a
AAI10825384
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
O'Connell, Dylan Patrick.
$3
3437572
245
1 0
$a
Development, Validation, and Translation of a Respiratory Motion Model-Based 4DCT Technique for Use as a Clinical Protocol for Radiation Therapy Treatment Planning.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2018
300
$a
143 p.
500
$a
Source: Dissertations Abstracts International, Volume: 79-12, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Low, Daniel A.
502
$a
Thesis (Ph.D.)--University of California, Los Angeles, 2018.
506
$a
This item must not be added to any third party search indexes.
506
$a
This item must not be sold to any third party vendors.
520
$a
Breathing motion in radiotherapy is commonly managed with four-dimensional computed tomography (4DCT). 4DCT datasets consist of multiple breathing-gated images that display motion of the subject's anatomy over a breathing period. Commercial 4DCT protocols are susceptible to image artifacts when the subject breathes irregularly. Unlike commercial protocols, model-based 4DCT techniques describe a correspondence between tissue motion and an external signal used as a surrogate for respiratory phase. One such technique, termed '5DCT,' uses free-breathing fast helical acquisition and characterizes lung tissue motion as function of five degrees of freedom: x,y, and z position in a reference geometry, breathing amplitude, and breathing rate. The overarching goal of this dissertation is to develop the 5DCT technique for clinical use. A validation study was conducted involving comparing 5DCT images to commercial 4DCT using an animal model. Reproducible and periodic breathing patterns were achieved through mechanical ventilation and image similarity was quantified using landmark displacement. Differences in measured tumor motion between 5DCT and commercial 4DCT were examined in a cohort of 20 lung cancer patients. Solutions for the unique challenges of using model model-based techniques clinically, such as appropriate amplitude interval selection and presentation of a quantitative error map, were developed. A quality management program was developed to ensure the safety of the protocol using risk analysis methods such as process mapping and failure modes and effects analysis. In addition, safety of the in-house software required to implement the technique was managed through use cases and quantitative, testable safety requirements. The physiological significance of the 5D model parameters was investigated, particularly their dependence on breathing rate during acquisition. It was shown that the model parameter relating tissue motion to breathing amplitude was largely invariant with breathing rate during acquisition. A prospective scanning method was developed to reduce the number of fast helical scans, and associated imaging dose, necessary to perform 5DCT while maintaining motion modeling accuracy. A simulation study was conducted using patient breathing traces, and the results demonstrated that adequate sampling of the respiratory cycle could be achieved using six scans, compared to the previously published protocol that employs twenty-five.
590
$a
School code: 0031.
650
4
$a
Medical imaging.
$3
3172799
690
$a
0574
710
2
$a
University of California, Los Angeles.
$b
Biomedical Physics.
$3
2101138
773
0
$t
Dissertations Abstracts International
$g
79-12B.
790
$a
0031
791
$a
Ph.D.
792
$a
2018
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10825384
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9386981
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入