Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Venous Thromboembolism (VTE) Harm Me...
~
Marashi, Seyed Mani.
Linked to FindBook
Google Book
Amazon
博客來
Venous Thromboembolism (VTE) Harm Measurement and Risk Assessment in Real-Time Using Electronic Health Records(EHR).
Record Type:
Electronic resources : Monograph/item
Title/Author:
Venous Thromboembolism (VTE) Harm Measurement and Risk Assessment in Real-Time Using Electronic Health Records(EHR)./
Author:
Marashi, Seyed Mani.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2018,
Description:
127 p.
Notes:
Source: Dissertations Abstracts International, Volume: 79-10, Section: B.
Contained By:
Dissertations Abstracts International79-10B.
Subject:
Information Technology. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10681845
ISBN:
9780355826845
Venous Thromboembolism (VTE) Harm Measurement and Risk Assessment in Real-Time Using Electronic Health Records(EHR).
Marashi, Seyed Mani.
Venous Thromboembolism (VTE) Harm Measurement and Risk Assessment in Real-Time Using Electronic Health Records(EHR).
- Ann Arbor : ProQuest Dissertations & Theses, 2018 - 127 p.
Source: Dissertations Abstracts International, Volume: 79-10, Section: B.
Thesis (Ph.D.)--Wayne State University, 2018.
This item must not be sold to any third party vendors.
Venous Thromboembolism (VTE) is a deadly disease and is considered as one of the top reasons for avoidable hospital deaths in the United States and around the world. Patients who survive this disease often must face life-long complications such as Post-thrombotic syndrome (PTS), Chronic thromboembolic pulmonary hypertension (CTPH), etc. Therefore, it is important to monitor and reduce the number of VTE instances in hospitals. This study shows how Electronic Health Records (EHRs) can be utilized to achieve this goal. First, a new near real-time VTE harm measurement model was developed. Not only the developed model can deliver near real-time results, but also it can outperform the existing PSI12 measurement model that uses administrative data (sensitivity 84% vs. 38% and NPV 99% vs. 95%). In the next step, Padua VTE risk assessment model was developed inside the EHR to deliver real-time VTE risk assessment. Retrospective data analysis was also performed to show how another risk assessment model (IMPROVE) can be developed inside EHR. Analysis were completed to show and compare the effectiveness of each model. Finally, the results of utilizing the developed models are presented in terms of contributions to savings for the health system as well as the number of lives saved.
ISBN: 9780355826845Subjects--Topical Terms:
1030799
Information Technology.
Venous Thromboembolism (VTE) Harm Measurement and Risk Assessment in Real-Time Using Electronic Health Records(EHR).
LDR
:02428nmm a2200337 4500
001
2207537
005
20190920131247.5
008
201008s2018 ||||||||||||||||| ||eng d
020
$a
9780355826845
035
$a
(MiAaPQ)AAI10681845
035
$a
(MiAaPQ)wayne:13538
035
$a
AAI10681845
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Marashi, Seyed Mani.
$3
3434523
245
1 0
$a
Venous Thromboembolism (VTE) Harm Measurement and Risk Assessment in Real-Time Using Electronic Health Records(EHR).
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2018
300
$a
127 p.
500
$a
Source: Dissertations Abstracts International, Volume: 79-10, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
500
$a
Advisor: Chelst, Kenneth R.
502
$a
Thesis (Ph.D.)--Wayne State University, 2018.
506
$a
This item must not be sold to any third party vendors.
520
$a
Venous Thromboembolism (VTE) is a deadly disease and is considered as one of the top reasons for avoidable hospital deaths in the United States and around the world. Patients who survive this disease often must face life-long complications such as Post-thrombotic syndrome (PTS), Chronic thromboembolic pulmonary hypertension (CTPH), etc. Therefore, it is important to monitor and reduce the number of VTE instances in hospitals. This study shows how Electronic Health Records (EHRs) can be utilized to achieve this goal. First, a new near real-time VTE harm measurement model was developed. Not only the developed model can deliver near real-time results, but also it can outperform the existing PSI12 measurement model that uses administrative data (sensitivity 84% vs. 38% and NPV 99% vs. 95%). In the next step, Padua VTE risk assessment model was developed inside the EHR to deliver real-time VTE risk assessment. Retrospective data analysis was also performed to show how another risk assessment model (IMPROVE) can be developed inside EHR. Analysis were completed to show and compare the effectiveness of each model. Finally, the results of utilizing the developed models are presented in terms of contributions to savings for the health system as well as the number of lives saved.
590
$a
School code: 0254.
650
4
$a
Information Technology.
$3
1030799
650
4
$a
Industrial engineering.
$3
526216
650
4
$a
Medicine.
$3
641104
690
$a
0489
690
$a
0546
690
$a
0564
710
2
$a
Wayne State University.
$b
Industrial Engineering.
$3
1023564
773
0
$t
Dissertations Abstracts International
$g
79-10B.
790
$a
0254
791
$a
Ph.D.
792
$a
2018
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10681845
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9384086
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login