Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Improved Methods for Motion-Compensa...
~
Figley, Chase Russell.
Linked to FindBook
Google Book
Amazon
博客來
Improved Methods for Motion-Compensating and Event-Related Spinal Functional Magnetic Resonance Imaging (fMRI).
Record Type:
Electronic resources : Monograph/item
Title/Author:
Improved Methods for Motion-Compensating and Event-Related Spinal Functional Magnetic Resonance Imaging (fMRI)./
Author:
Figley, Chase Russell.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2010,
Description:
227 p.
Notes:
Source: Dissertations Abstracts International, Volume: 72-09, Section: B.
Contained By:
Dissertations Abstracts International72-09B.
Subject:
Neurosciences. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR70388
ISBN:
9780494703885
Improved Methods for Motion-Compensating and Event-Related Spinal Functional Magnetic Resonance Imaging (fMRI).
Figley, Chase Russell.
Improved Methods for Motion-Compensating and Event-Related Spinal Functional Magnetic Resonance Imaging (fMRI).
- Ann Arbor : ProQuest Dissertations & Theses, 2010 - 227 p.
Source: Dissertations Abstracts International, Volume: 72-09, Section: B.
Thesis (Ph.D.)--Queen's University (Canada), 2010.
This item must not be sold to any third party vendors.
Functional magnetic resonance imaging (fMRI) has become a widely used technique for non-invasive brain mapping, and methods have now evolved to allow fMRI of the spinal cord (spinal fMRI) as well. With the goal of improving spinal fMRI, the studies presented herein have investigated potential sources of noise that might limit its sensitivity and reliability. For example, multiple studies had previously suggested that the majority of structured physiological noise, such as spinal cord motion and cerebrospinal fluid (CSF) flow, appeared to be synchronous with cardiac pulsations. Therefore, we measured cardiac-related spinal cord motion at various levels along the cord, finding that peak anterior-posterior spinal cord displacements often exceeded 0.5 mm throughout the cervical and upper-thoracic regions. On the other hand, we found that cord motion throughout the lower-thoracic, lumbar and sacral levels was consistently small. Based on these findings, we concluded that cord motion is likely to be a significant source of error in spinal fMRI throughout superior, but not inferior, cord regions. Since all motion measurements were acquired at 24 phases of the cardiac cycle, this also allowed us to determine, and subsequently model, the main components of cardiac-related spinal cord motion. By then including these terms in a general linear model (GLM) analysis and reanalyzing 100 previously acquired cervical spinal fMRI datasets, we showed that the sensitivity and specificity were improved by 15-20 % and 5-6 %, respectively, over previous spinal fMRI methods. To push the limits of these improvements, we then carried out the first event-related spinal fMRI study, consistently observing spinal cord responses to 1 s applications of 22 °C thermal stimulation. By measuring these responses at many different phases, we were also able, for the first time, to characterize the impulse response function of SEEP (signal enhancement by extravascular water protons) contrast in the human cervical spinal cord.
ISBN: 9780494703885Subjects--Topical Terms:
588700
Neurosciences.
Improved Methods for Motion-Compensating and Event-Related Spinal Functional Magnetic Resonance Imaging (fMRI).
LDR
:03130nmm a2200313 4500
001
2207335
005
20190916101822.5
008
201008s2010 ||||||||||||||||| ||eng d
020
$a
9780494703885
035
$a
(MiAaPQ)AAINR70388
035
$a
AAINR70388
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Figley, Chase Russell.
$3
3434319
245
1 0
$a
Improved Methods for Motion-Compensating and Event-Related Spinal Functional Magnetic Resonance Imaging (fMRI).
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2010
300
$a
227 p.
500
$a
Source: Dissertations Abstracts International, Volume: 72-09, Section: B.
500
$a
Publisher info.: Dissertation/Thesis.
502
$a
Thesis (Ph.D.)--Queen's University (Canada), 2010.
506
$a
This item must not be sold to any third party vendors.
506
$a
This item must not be added to any third party search indexes.
520
$a
Functional magnetic resonance imaging (fMRI) has become a widely used technique for non-invasive brain mapping, and methods have now evolved to allow fMRI of the spinal cord (spinal fMRI) as well. With the goal of improving spinal fMRI, the studies presented herein have investigated potential sources of noise that might limit its sensitivity and reliability. For example, multiple studies had previously suggested that the majority of structured physiological noise, such as spinal cord motion and cerebrospinal fluid (CSF) flow, appeared to be synchronous with cardiac pulsations. Therefore, we measured cardiac-related spinal cord motion at various levels along the cord, finding that peak anterior-posterior spinal cord displacements often exceeded 0.5 mm throughout the cervical and upper-thoracic regions. On the other hand, we found that cord motion throughout the lower-thoracic, lumbar and sacral levels was consistently small. Based on these findings, we concluded that cord motion is likely to be a significant source of error in spinal fMRI throughout superior, but not inferior, cord regions. Since all motion measurements were acquired at 24 phases of the cardiac cycle, this also allowed us to determine, and subsequently model, the main components of cardiac-related spinal cord motion. By then including these terms in a general linear model (GLM) analysis and reanalyzing 100 previously acquired cervical spinal fMRI datasets, we showed that the sensitivity and specificity were improved by 15-20 % and 5-6 %, respectively, over previous spinal fMRI methods. To push the limits of these improvements, we then carried out the first event-related spinal fMRI study, consistently observing spinal cord responses to 1 s applications of 22 °C thermal stimulation. By measuring these responses at many different phases, we were also able, for the first time, to characterize the impulse response function of SEEP (signal enhancement by extravascular water protons) contrast in the human cervical spinal cord.
590
$a
School code: 0283.
650
4
$a
Neurosciences.
$3
588700
650
4
$a
Medical imaging.
$3
3172799
690
$a
0317
690
$a
0574
710
2
$a
Queen's University (Canada).
$3
1017786
773
0
$t
Dissertations Abstracts International
$g
72-09B.
790
$a
0283
791
$a
Ph.D.
792
$a
2010
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR70388
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9383884
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login