Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Foundational Studies for Array-based...
~
Zhu, Fanyi.
Linked to FindBook
Google Book
Amazon
博客來
Foundational Studies for Array-based Electrophoretic Exclusion of Proteins.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Foundational Studies for Array-based Electrophoretic Exclusion of Proteins./
Author:
Zhu, Fanyi.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2019,
Description:
187 p.
Notes:
Source: Dissertation Abstracts International, Volume: 80-09(E), Section: B.
Contained By:
Dissertation Abstracts International80-09B(E).
Subject:
Chemistry. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13864273
ISBN:
9781392141236
Foundational Studies for Array-based Electrophoretic Exclusion of Proteins.
Zhu, Fanyi.
Foundational Studies for Array-based Electrophoretic Exclusion of Proteins.
- Ann Arbor : ProQuest Dissertations & Theses, 2019 - 187 p.
Source: Dissertation Abstracts International, Volume: 80-09(E), Section: B.
Thesis (Ph.D.)--Arizona State University, 2019.
Disease prevention and personalized treatment will be impacted by the continued integration of protein biomarkers into medical practice. While there are already numerous biomarkers used clinically, the detection of protein biomarkers among complex matrices remains a challenging problem. One very important strategy for improvements in clinical application of biomarkers is separation/preconcentration, impacting the reliability, efficiency and early detection. Electrophoretic exclusion can be used to separate, purify, and concentrate biomarkers. This counterflow gradient technique exploits hydrodynamic flow and electrophoretic forces to exclude, enrich, and separate analytes. The development of this technique has evolved onto an array-based microfluidic platform which offers a greater range of geometries/configurations for optimization and expanded capabilities and applications. Toward this end of expanded capabilities, fundamental studies of subtle changes to the entrance flow and electric field configurations are investigated. Three closely related microfluidic interfaces are modeled, fabricated and tested. A charged fluorescent dye is used as a sensitive and accurate probe to test the concentration variation at these interfaces. Models and experiments focus on visualizing the concentration profile in areas of high temporal dynamics, and show strong qualitative agreement, which suggests the theoretical assessment capabilities can be used to faithfully design novel and more efficient interfaces. Microfluidic electrophoretic separation technique can be combined with electron microscopy as a protein concentration/purification step aiding in sample preparation. The integrated system with grids embedded into the microdevice reduces the amount of time required for sample preparation to less than five minutes. Spatially separated and preconcentrated proteins are transferred directly from an upstream reservoir onto grids. Dilute concentration as low as 0.005 mg/mL can be manipulated to achieve meaningful results. Selective concentration of one protein from a mixture of two proteins is also demonstrated. Electrophoretic exclusion is also used for biomarker applications. Experiments using a single biomarker are conducted to assess the ability of the microdevice for enrichment in central reservoirs. A mixture of two protein biomarkers are performed to evaluate the proficiency of the device for separations capability. Moreover, a battery is able to power the microdevice, which facilitates the future application as a portable device.
ISBN: 9781392141236Subjects--Topical Terms:
516420
Chemistry.
Foundational Studies for Array-based Electrophoretic Exclusion of Proteins.
LDR
:03505nmm a2200301 4500
001
2204102
005
20190624102129.5
008
201008s2019 ||||||||||||||||| ||eng d
020
$a
9781392141236
035
$a
(MiAaPQ)AAI13864273
035
$a
(MiAaPQ)asu:18958
035
$a
AAI13864273
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Zhu, Fanyi.
$3
3430922
245
1 0
$a
Foundational Studies for Array-based Electrophoretic Exclusion of Proteins.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2019
300
$a
187 p.
500
$a
Source: Dissertation Abstracts International, Volume: 80-09(E), Section: B.
500
$a
Adviser: Mark Hayes.
502
$a
Thesis (Ph.D.)--Arizona State University, 2019.
520
$a
Disease prevention and personalized treatment will be impacted by the continued integration of protein biomarkers into medical practice. While there are already numerous biomarkers used clinically, the detection of protein biomarkers among complex matrices remains a challenging problem. One very important strategy for improvements in clinical application of biomarkers is separation/preconcentration, impacting the reliability, efficiency and early detection. Electrophoretic exclusion can be used to separate, purify, and concentrate biomarkers. This counterflow gradient technique exploits hydrodynamic flow and electrophoretic forces to exclude, enrich, and separate analytes. The development of this technique has evolved onto an array-based microfluidic platform which offers a greater range of geometries/configurations for optimization and expanded capabilities and applications. Toward this end of expanded capabilities, fundamental studies of subtle changes to the entrance flow and electric field configurations are investigated. Three closely related microfluidic interfaces are modeled, fabricated and tested. A charged fluorescent dye is used as a sensitive and accurate probe to test the concentration variation at these interfaces. Models and experiments focus on visualizing the concentration profile in areas of high temporal dynamics, and show strong qualitative agreement, which suggests the theoretical assessment capabilities can be used to faithfully design novel and more efficient interfaces. Microfluidic electrophoretic separation technique can be combined with electron microscopy as a protein concentration/purification step aiding in sample preparation. The integrated system with grids embedded into the microdevice reduces the amount of time required for sample preparation to less than five minutes. Spatially separated and preconcentrated proteins are transferred directly from an upstream reservoir onto grids. Dilute concentration as low as 0.005 mg/mL can be manipulated to achieve meaningful results. Selective concentration of one protein from a mixture of two proteins is also demonstrated. Electrophoretic exclusion is also used for biomarker applications. Experiments using a single biomarker are conducted to assess the ability of the microdevice for enrichment in central reservoirs. A mixture of two protein biomarkers are performed to evaluate the proficiency of the device for separations capability. Moreover, a battery is able to power the microdevice, which facilitates the future application as a portable device.
590
$a
School code: 0010.
650
4
$a
Chemistry.
$3
516420
650
4
$a
Analytical chemistry.
$3
3168300
690
$a
0485
690
$a
0486
710
2
$a
Arizona State University.
$b
Chemistry.
$3
2096519
773
0
$t
Dissertation Abstracts International
$g
80-09B(E).
790
$a
0010
791
$a
Ph.D.
792
$a
2019
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=13864273
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9380651
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login