Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
The Impacts of Cooking and an Assess...
~
Militello-Hourigan, Ryan Edward.
Linked to FindBook
Google Book
Amazon
博客來
The Impacts of Cooking and an Assessment of Indoor Air Quality in Colorado Passive and Tightly Constructed Homes.
Record Type:
Electronic resources : Monograph/item
Title/Author:
The Impacts of Cooking and an Assessment of Indoor Air Quality in Colorado Passive and Tightly Constructed Homes./
Author:
Militello-Hourigan, Ryan Edward.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2018,
Description:
48 p.
Notes:
Source: Masters Abstracts International, Volume: 57-06.
Contained By:
Masters Abstracts International57-06(E).
Subject:
Mechanical engineering. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10809722
ISBN:
9780438045507
The Impacts of Cooking and an Assessment of Indoor Air Quality in Colorado Passive and Tightly Constructed Homes.
Militello-Hourigan, Ryan Edward.
The Impacts of Cooking and an Assessment of Indoor Air Quality in Colorado Passive and Tightly Constructed Homes.
- Ann Arbor : ProQuest Dissertations & Theses, 2018 - 48 p.
Source: Masters Abstracts International, Volume: 57-06.
Thesis (M.S.)--University of Colorado at Boulder, 2018.
Low-energy home design is becoming more common in new and retrofitted homes, and energy-efficient designs often sell at a premium. This perceived and realized value of reducing energy use in homes is important as the need to reduce fossil fuel use becomes increasingly critical. Energy efficiency measures, like tightening the envelope of a home saves energy, but can impact the indoor air quality. We monitored the indoor air quality of nine tightly constructed homes, one tightly constructed public library, and one conventionally constructed home, and performed a repeatable cooking activity to observe the impact and response to the resulting fine particulate matter (PM2.5) emissions. We compared the PM2.5 concentrations from the cooking activity while operating the mechanical ventilation systems at default rates (~0.1--0.3 h--1) and in a temporary boost mode (~0.3--0.8 h--1). We also measured the concentrations of total volatile organic compounds (TVOCs), formaldehyde, radon, and bedroom carbon dioxide (CO2) levels. Results show that fine particulate matter concentrations are generally low indoors, but a cooking event drastically increases concentrations and levels are slow to decay. Median time above 35 microg/m3 after cooking was 4.7 hours. Overall, there was not a significant difference between operating the ventilators at standard rates and utilizing the temporary boost. Completely-mixed flow reactor models of select tested homes show that installing and using a directly-exhausting range hood could reduce peak PM 2.5 concentrations by 75% or more. Current ventilation practices in these buildings may not be adequate for these common polluting events. TVOC concentrations were generally low with a median average of 459 microg/m 3. Formaldehyde was above the California Office of Environmental Health Hazard Assessment (OEHHA) chronic limit of 9 microg/m3 across all tight buildings with a median value of 30 microg/m3. Carbon dioxide levels in bedrooms were high at night (> 1000 ppm) in six of the homes, indicating that current bedroom ventilation practices are not consistent nor adequate. Bedroom air exchange rates (AER) determined from carbon dioxide decay ranged from 0.08 to 0.30 h--1 with a median value of 0.12 h--1.
ISBN: 9780438045507Subjects--Topical Terms:
649730
Mechanical engineering.
The Impacts of Cooking and an Assessment of Indoor Air Quality in Colorado Passive and Tightly Constructed Homes.
LDR
:03244nmm a2200313 4500
001
2201983
005
20190503113354.5
008
201008s2018 ||||||||||||||||| ||eng d
020
$a
9780438045507
035
$a
(MiAaPQ)AAI10809722
035
$a
(MiAaPQ)colorado:15518
035
$a
AAI10809722
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Militello-Hourigan, Ryan Edward.
$3
3428736
245
1 4
$a
The Impacts of Cooking and an Assessment of Indoor Air Quality in Colorado Passive and Tightly Constructed Homes.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2018
300
$a
48 p.
500
$a
Source: Masters Abstracts International, Volume: 57-06.
500
$a
Adviser: Shelly L. Miller.
502
$a
Thesis (M.S.)--University of Colorado at Boulder, 2018.
520
$a
Low-energy home design is becoming more common in new and retrofitted homes, and energy-efficient designs often sell at a premium. This perceived and realized value of reducing energy use in homes is important as the need to reduce fossil fuel use becomes increasingly critical. Energy efficiency measures, like tightening the envelope of a home saves energy, but can impact the indoor air quality. We monitored the indoor air quality of nine tightly constructed homes, one tightly constructed public library, and one conventionally constructed home, and performed a repeatable cooking activity to observe the impact and response to the resulting fine particulate matter (PM2.5) emissions. We compared the PM2.5 concentrations from the cooking activity while operating the mechanical ventilation systems at default rates (~0.1--0.3 h--1) and in a temporary boost mode (~0.3--0.8 h--1). We also measured the concentrations of total volatile organic compounds (TVOCs), formaldehyde, radon, and bedroom carbon dioxide (CO2) levels. Results show that fine particulate matter concentrations are generally low indoors, but a cooking event drastically increases concentrations and levels are slow to decay. Median time above 35 microg/m3 after cooking was 4.7 hours. Overall, there was not a significant difference between operating the ventilators at standard rates and utilizing the temporary boost. Completely-mixed flow reactor models of select tested homes show that installing and using a directly-exhausting range hood could reduce peak PM 2.5 concentrations by 75% or more. Current ventilation practices in these buildings may not be adequate for these common polluting events. TVOC concentrations were generally low with a median average of 459 microg/m 3. Formaldehyde was above the California Office of Environmental Health Hazard Assessment (OEHHA) chronic limit of 9 microg/m3 across all tight buildings with a median value of 30 microg/m3. Carbon dioxide levels in bedrooms were high at night (> 1000 ppm) in six of the homes, indicating that current bedroom ventilation practices are not consistent nor adequate. Bedroom air exchange rates (AER) determined from carbon dioxide decay ranged from 0.08 to 0.30 h--1 with a median value of 0.12 h--1.
590
$a
School code: 0051.
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Civil engineering.
$3
860360
650
4
$a
Environmental health.
$3
543032
690
$a
0548
690
$a
0543
690
$a
0470
710
2
$a
University of Colorado at Boulder.
$b
Mechanical Engineering.
$3
1030435
773
0
$t
Masters Abstracts International
$g
57-06(E).
790
$a
0051
791
$a
M.S.
792
$a
2018
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10809722
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9378532
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login