Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
New Classifier Architecture and Trai...
~
Narayanan, Barath Narayanan.
Linked to FindBook
Google Book
Amazon
博客來
New Classifier Architecture and Training Methodologies for Lung Nodule Detection in Chest Radiographs and Computed Tomography.
Record Type:
Electronic resources : Monograph/item
Title/Author:
New Classifier Architecture and Training Methodologies for Lung Nodule Detection in Chest Radiographs and Computed Tomography./
Author:
Narayanan, Barath Narayanan.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2017,
Description:
95 p.
Notes:
Source: Dissertation Abstracts International, Volume: 79-12(E), Section: B.
Contained By:
Dissertation Abstracts International79-12B(E).
Subject:
Electrical engineering. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10947966
ISBN:
9780438195844
New Classifier Architecture and Training Methodologies for Lung Nodule Detection in Chest Radiographs and Computed Tomography.
Narayanan, Barath Narayanan.
New Classifier Architecture and Training Methodologies for Lung Nodule Detection in Chest Radiographs and Computed Tomography.
- Ann Arbor : ProQuest Dissertations & Theses, 2017 - 95 p.
Source: Dissertation Abstracts International, Volume: 79-12(E), Section: B.
Thesis (Dr.Ph.)--University of Dayton, 2017.
Early detection of pulmonary lung nodules plays a significant role in the diagnosis of lung cancer. Radiologists use Computed Tomography (CT) and Chest Radiographs (CRs) to detect such nodules. In this research, we propose various pattern recognition algorithms to enhance the classification performance of the Computer Aided Detection (CAD) system for lung nodule detection in both modalities. We propose a novel optimized method of feature selection for clustering that would aid the performance of the classifier. We make use of an independent CR database for training purposes. Testing is implemented on a publicly available database created by the Standard Digital Image Database Project Team of the Scientific Committee of the Japanese Society of Radiological Technology (JRST). The JRST database comprises 154 CRs containing one radiologist confirmed nodule in each. We make use of 107 CT scans from publicly available dataset created by Lung Image Database Consortium (LIDC) for this study. We compare the performance of the cluster-classifier architecture to a single aggregate classifier architecture. Overall, with a specificity of 3 false positives per case on an average, we show a classifier performance boost of 7.7% for CRs and 5.0% for CT scans when compared to single aggregate classifier architecture.
ISBN: 9780438195844Subjects--Topical Terms:
649834
Electrical engineering.
New Classifier Architecture and Training Methodologies for Lung Nodule Detection in Chest Radiographs and Computed Tomography.
LDR
:03750nmm a2200325 4500
001
2163410
005
20181022132250.5
008
190424s2017 ||||||||||||||||| ||eng d
020
$a
9780438195844
035
$a
(MiAaPQ)AAI10947966
035
$a
(MiAaPQ)OhioLINK:dayton1508237793168873
035
$a
AAI10947966
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Narayanan, Barath Narayanan.
$3
3351429
245
1 0
$a
New Classifier Architecture and Training Methodologies for Lung Nodule Detection in Chest Radiographs and Computed Tomography.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2017
300
$a
95 p.
500
$a
Source: Dissertation Abstracts International, Volume: 79-12(E), Section: B.
500
$a
Adviser: Russell C. Hardie.
502
$a
Thesis (Dr.Ph.)--University of Dayton, 2017.
520
$a
Early detection of pulmonary lung nodules plays a significant role in the diagnosis of lung cancer. Radiologists use Computed Tomography (CT) and Chest Radiographs (CRs) to detect such nodules. In this research, we propose various pattern recognition algorithms to enhance the classification performance of the Computer Aided Detection (CAD) system for lung nodule detection in both modalities. We propose a novel optimized method of feature selection for clustering that would aid the performance of the classifier. We make use of an independent CR database for training purposes. Testing is implemented on a publicly available database created by the Standard Digital Image Database Project Team of the Scientific Committee of the Japanese Society of Radiological Technology (JRST). The JRST database comprises 154 CRs containing one radiologist confirmed nodule in each. We make use of 107 CT scans from publicly available dataset created by Lung Image Database Consortium (LIDC) for this study. We compare the performance of the cluster-classifier architecture to a single aggregate classifier architecture. Overall, with a specificity of 3 false positives per case on an average, we show a classifier performance boost of 7.7% for CRs and 5.0% for CT scans when compared to single aggregate classifier architecture.
520
$a
Furthermore, we study the performance of a CAD system in CT scans as a function of slice thickness. We believe this study has implication for how CT is acquired, processed and stored. We make use of CT cases acquired at a thickness of 1.25mm from the publicly available Lung Nodule Analysis 2016 (LUNA16) dataset for this research. We study the CAD performance at a native thickness of 1.25mm and various other down-sampled stages. Our study indicates that CAD performance at 2.5mm is comparable to 1.25mm and is much better than at higher thicknesses. In addition, we propose and compare three different training methodologies for utilizing non-homogenous thickness training (i.e., composed of cases with different slice thicknesses). We utilize cases acquired at 1.25mm and 2.5mm respectively from the LUNA16 dataset for this study. These methods include: (1) aggregate training using the entire suite of data at their native thickness, (2) homogeneous subset training that uses the subset of training data that matches each testing case; and (3) resampling all training and testing cases to a common thickness. Our experimental results indicate that resampling all training and testing cases to 2.5mm provides the best performance among the three training methods compared. Furthermore, the resampled 2.5mm data require less memory and process faster than the 1.25mm data.
590
$a
School code: 0327.
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Medical imaging.
$3
3172799
650
4
$a
Biomedical engineering.
$3
535387
690
$a
0544
690
$a
0574
690
$a
0541
710
2
$a
University of Dayton.
$b
Electrical and Computer Engineering.
$3
3345480
773
0
$t
Dissertation Abstracts International
$g
79-12B(E).
790
$a
0327
791
$a
Dr.Ph.
792
$a
2017
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10947966
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9362957
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login