語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Handheld total chemical and biologic...
~
Lei, Ka-Meng.
FindBook
Google Book
Amazon
博客來
Handheld total chemical and biological analysis systems = bridging NMR, digital microfluidics, and semiconductors /
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Handheld total chemical and biological analysis systems/ by Ka-Meng Lei ... [et al.].
其他題名:
bridging NMR, digital microfluidics, and semiconductors /
其他作者:
Lei, Ka-Meng.
出版者:
Cham :Springer International Publishing : : 2018.,
面頁冊數:
xxi, 102 p. :ill., digital ;24 cm.
內容註:
Introduction -- State-of-the-Art CMOS In Vitro Diagnostic Devices -- Electronic-Automated Micro-NMR Assay with DMF Device -- One-Chip Micro-NMR Platform with B0-field Stabilization -- Conclusion and Outlook -- Appendix -- Index.
Contained By:
Springer eBooks
標題:
Analytical biochemistry. -
電子資源:
http://dx.doi.org/10.1007/978-3-319-67825-2
ISBN:
9783319678252
Handheld total chemical and biological analysis systems = bridging NMR, digital microfluidics, and semiconductors /
Handheld total chemical and biological analysis systems
bridging NMR, digital microfluidics, and semiconductors /[electronic resource] :by Ka-Meng Lei ... [et al.]. - Cham :Springer International Publishing :2018. - xxi, 102 p. :ill., digital ;24 cm.
Introduction -- State-of-the-Art CMOS In Vitro Diagnostic Devices -- Electronic-Automated Micro-NMR Assay with DMF Device -- One-Chip Micro-NMR Platform with B0-field Stabilization -- Conclusion and Outlook -- Appendix -- Index.
The book Handheld Total Chemical and Biological Analysis Systems: Bridging NMR, Digital Microfluidics, and Semiconductors centers on the complete design of Nuclear Magnetic Resonance (NMR) microsystems for in vitro chemical and biological assays based on semiconductor chips and portable magnet. Different sensing mechanisms for CMOS in vitro assay are compared, key design criteria of the CMOS transceiver for NMR measurement are revealed, and system-level optimizations of the CMOS NMR platform utilizing digital microfluidic and diverse functions of the CMOS technology are discussed. Two CMOS NMR platforms are implemented, each of these focuses on different aspect of optimization. Shows literature review about state-of-the-art CMOS in vitro diagnosis systems and their sensing mechanisms; Shows brief physics background on biological sensing with NMR; Shows detailed design of the CMOS transceiver for NMR experiments; Describes the first CMOS NMR platform integrated with digital microfluidic devices for electronic-automated sample management; Demonstrates magnetic field stabilization for the portable magnet to enhance the robustness of the NMR platform with the aid of CMOS vertical Hall sensor.
ISBN: 9783319678252
Standard No.: 10.1007/978-3-319-67825-2doiSubjects--Topical Terms:
586155
Analytical biochemistry.
LC Class. No.: QP519.7
Dewey Class. No.: 572.36
Handheld total chemical and biological analysis systems = bridging NMR, digital microfluidics, and semiconductors /
LDR
:02430nmm a2200313 a 4500
001
2131697
003
DE-He213
005
20180620090750.0
006
m d
007
cr nn 008maaau
008
181005s2018 gw s 0 eng d
020
$a
9783319678252
$q
(electronic bk.)
020
$a
9783319678245
$q
(paper)
024
7
$a
10.1007/978-3-319-67825-2
$2
doi
035
$a
978-3-319-67825-2
040
$a
GP
$c
GP
041
0
$a
eng
050
4
$a
QP519.7
072
7
$a
TJFC
$2
bicssc
072
7
$a
TEC008010
$2
bisacsh
082
0 4
$a
572.36
$2
23
090
$a
QP519.7
$b
.H236 2018
245
0 0
$a
Handheld total chemical and biological analysis systems
$h
[electronic resource] :
$b
bridging NMR, digital microfluidics, and semiconductors /
$c
by Ka-Meng Lei ... [et al.].
260
$a
Cham :
$b
Springer International Publishing :
$b
Imprint: Springer,
$c
2018.
300
$a
xxi, 102 p. :
$b
ill., digital ;
$c
24 cm.
505
0
$a
Introduction -- State-of-the-Art CMOS In Vitro Diagnostic Devices -- Electronic-Automated Micro-NMR Assay with DMF Device -- One-Chip Micro-NMR Platform with B0-field Stabilization -- Conclusion and Outlook -- Appendix -- Index.
520
$a
The book Handheld Total Chemical and Biological Analysis Systems: Bridging NMR, Digital Microfluidics, and Semiconductors centers on the complete design of Nuclear Magnetic Resonance (NMR) microsystems for in vitro chemical and biological assays based on semiconductor chips and portable magnet. Different sensing mechanisms for CMOS in vitro assay are compared, key design criteria of the CMOS transceiver for NMR measurement are revealed, and system-level optimizations of the CMOS NMR platform utilizing digital microfluidic and diverse functions of the CMOS technology are discussed. Two CMOS NMR platforms are implemented, each of these focuses on different aspect of optimization. Shows literature review about state-of-the-art CMOS in vitro diagnosis systems and their sensing mechanisms; Shows brief physics background on biological sensing with NMR; Shows detailed design of the CMOS transceiver for NMR experiments; Describes the first CMOS NMR platform integrated with digital microfluidic devices for electronic-automated sample management; Demonstrates magnetic field stabilization for the portable magnet to enhance the robustness of the NMR platform with the aid of CMOS vertical Hall sensor.
650
0
$a
Analytical biochemistry.
$3
586155
650
0
$a
Nuclear magnetic resonance spectroscopy.
$3
560451
650
0
$a
Metal oxide semiconductors, Complementary.
$3
649504
650
1 4
$a
Engineering.
$3
586835
650
2 4
$a
Circuits and Systems.
$3
896527
650
2 4
$a
Electronics and Microelectronics, Instrumentation.
$3
893838
650
2 4
$a
Biomedical Engineering.
$3
720279
700
1
$a
Lei, Ka-Meng.
$3
3297517
710
2
$a
SpringerLink (Online service)
$3
836513
773
0
$t
Springer eBooks
856
4 0
$u
http://dx.doi.org/10.1007/978-3-319-67825-2
950
$a
Engineering (Springer-11647)
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9340432
電子資源
11.線上閱覽_V
電子書
EB QP519.7
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入