Enzymatic Biosensor and Biofuel Cell...
~
Campbell, Alan S.
FindBook
Google Book
Amazon
博客來
Enzymatic Biosensor and Biofuel Cell Development Using Carbon Nanomaterials and Polymer-Based Protein Engineering.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Enzymatic Biosensor and Biofuel Cell Development Using Carbon Nanomaterials and Polymer-Based Protein Engineering./
作者:
Campbell, Alan S.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2017,
面頁冊數:
218 p.
附註:
Source: Dissertation Abstracts International, Volume: 78-09(E), Section: B.
Contained By:
Dissertation Abstracts International78-09B(E).
標題:
Biomedical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10271401
ISBN:
9781369729504
Enzymatic Biosensor and Biofuel Cell Development Using Carbon Nanomaterials and Polymer-Based Protein Engineering.
Campbell, Alan S.
Enzymatic Biosensor and Biofuel Cell Development Using Carbon Nanomaterials and Polymer-Based Protein Engineering.
- Ann Arbor : ProQuest Dissertations & Theses, 2017 - 218 p.
Source: Dissertation Abstracts International, Volume: 78-09(E), Section: B.
Thesis (Ph.D.)--Carnegie Mellon University, 2017.
The development of enzymatic biosensors and enzymatic biofuel cells (EBFCs) has been a significant area of research for decades. Enzymatic catalysis can provide for specific, reliable sensing of target analytes as well as the continuous generation of power from physiologically present fuels. However, the broad implementation of enzyme-based devices is still limited by low operational/storage stabilities and insufficient power densities. Approaches to improving upon these limitations have focused on the optimization of enzyme activity and electron transfer kinetics at enzyme-functionalized electrodes. Currently, such optimization can be performed through enzyme structural engineering, improvement of enzyme immobilization methodologies, and fabrication of advantageous electrode materials to enhance retained enzyme activity density at the electrode surface and electron transfer rates between enzymes and an electrode. In this work, varying electrode materials were studied to produce an increased understanding on the impacts of material properties on resulting biochemical, and electrochemical performances upon enzyme immobilization and an additional method of electroactive enzyme-based optimization was developed through the use of polymer-based protein engineering (PBPE). First, graphene/single-wall carbon nanotube cogels were studied as supports for membrane- and mediator-free EBFCs. The high available specific surface area and porosity of these materials allowed the rechargeable generation of a power density within one order of magnitude of the highest performing glucose-based EBFCs to date. Second, two additional carbon nanomaterial-based electrode materials were fabricated and examined as EBFC electrodes. Graphene-coated single-wall carbon nanotube gels and gold nanoparticle/multi-wall carbon nanotube-coated polyacrylonitrile fiber paddles were utilized as electroactive enzyme supports. The performance comparison of these three materials provided an increased understanding of the impact of material properties such as pore size, specific surface area and material surface curvature on enzyme biochemical and electrochemical characteristics upon immobilization. Third, PBPE techniques were applied to develop enzyme-redox polymer conjugates as a new platform for enzymatic biosensor and EBFC optimization. Poly(N-(3-dimethyl(ferrocenyl) methylammonium bromide)propyl acrylamide) (pFcAc) was grown directly from the surface of glucose oxidase (GOX) through atom-transfer radical polymerization. Utilization of the synthesized GOX-pFcAc conjugates led to a 24-fold increase in current generation efficiency and a 4-fold increase in EBFC power density compared to native GOX. GOX-pFcAc conjugates were further examined as working catalysts in carbon paper-based enzymatic biosensors, which provided reliable and selective glucose sensitivities and allowed a systematic analysis of sources of instability in enzyme-polymer conjugate-based biosensors and EBFCs. The knowledge gained through these studies and the in-depth characterization of an additional layer of optimization capacity using PBPE could potentially enhance the progress of enzymatic biosensor and EBFC development.
ISBN: 9781369729504Subjects--Topical Terms:
535387
Biomedical engineering.
Enzymatic Biosensor and Biofuel Cell Development Using Carbon Nanomaterials and Polymer-Based Protein Engineering.
LDR
:04202nmm a2200301 4500
001
2122682
005
20170922124937.5
008
180830s2017 ||||||||||||||||| ||eng d
020
$a
9781369729504
035
$a
(MiAaPQ)AAI10271401
035
$a
AAI10271401
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Campbell, Alan S.
$3
3284648
245
1 0
$a
Enzymatic Biosensor and Biofuel Cell Development Using Carbon Nanomaterials and Polymer-Based Protein Engineering.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2017
300
$a
218 p.
500
$a
Source: Dissertation Abstracts International, Volume: 78-09(E), Section: B.
500
$a
Advisers: Alan J. Russell; Mohammad F. Islam.
502
$a
Thesis (Ph.D.)--Carnegie Mellon University, 2017.
520
$a
The development of enzymatic biosensors and enzymatic biofuel cells (EBFCs) has been a significant area of research for decades. Enzymatic catalysis can provide for specific, reliable sensing of target analytes as well as the continuous generation of power from physiologically present fuels. However, the broad implementation of enzyme-based devices is still limited by low operational/storage stabilities and insufficient power densities. Approaches to improving upon these limitations have focused on the optimization of enzyme activity and electron transfer kinetics at enzyme-functionalized electrodes. Currently, such optimization can be performed through enzyme structural engineering, improvement of enzyme immobilization methodologies, and fabrication of advantageous electrode materials to enhance retained enzyme activity density at the electrode surface and electron transfer rates between enzymes and an electrode. In this work, varying electrode materials were studied to produce an increased understanding on the impacts of material properties on resulting biochemical, and electrochemical performances upon enzyme immobilization and an additional method of electroactive enzyme-based optimization was developed through the use of polymer-based protein engineering (PBPE). First, graphene/single-wall carbon nanotube cogels were studied as supports for membrane- and mediator-free EBFCs. The high available specific surface area and porosity of these materials allowed the rechargeable generation of a power density within one order of magnitude of the highest performing glucose-based EBFCs to date. Second, two additional carbon nanomaterial-based electrode materials were fabricated and examined as EBFC electrodes. Graphene-coated single-wall carbon nanotube gels and gold nanoparticle/multi-wall carbon nanotube-coated polyacrylonitrile fiber paddles were utilized as electroactive enzyme supports. The performance comparison of these three materials provided an increased understanding of the impact of material properties such as pore size, specific surface area and material surface curvature on enzyme biochemical and electrochemical characteristics upon immobilization. Third, PBPE techniques were applied to develop enzyme-redox polymer conjugates as a new platform for enzymatic biosensor and EBFC optimization. Poly(N-(3-dimethyl(ferrocenyl) methylammonium bromide)propyl acrylamide) (pFcAc) was grown directly from the surface of glucose oxidase (GOX) through atom-transfer radical polymerization. Utilization of the synthesized GOX-pFcAc conjugates led to a 24-fold increase in current generation efficiency and a 4-fold increase in EBFC power density compared to native GOX. GOX-pFcAc conjugates were further examined as working catalysts in carbon paper-based enzymatic biosensors, which provided reliable and selective glucose sensitivities and allowed a systematic analysis of sources of instability in enzyme-polymer conjugate-based biosensors and EBFCs. The knowledge gained through these studies and the in-depth characterization of an additional layer of optimization capacity using PBPE could potentially enhance the progress of enzymatic biosensor and EBFC development.
590
$a
School code: 0041.
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Biochemistry.
$3
518028
650
4
$a
Polymer chemistry.
$3
3173488
690
$a
0541
690
$a
0487
690
$a
0495
710
2
$a
Carnegie Mellon University.
$b
Biomedical Engineering.
$3
3284644
773
0
$t
Dissertation Abstracts International
$g
78-09B(E).
790
$a
0041
791
$a
Ph.D.
792
$a
2017
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10271401
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9333296
電子資源
01.外借(書)_YB
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入