Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Analytical methods to enhance detect...
~
Rosenberg, Brett L.
Linked to FindBook
Google Book
Amazon
博客來
Analytical methods to enhance detection of anthropogenic radionuclides in environmental matrices.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Analytical methods to enhance detection of anthropogenic radionuclides in environmental matrices./
Author:
Rosenberg, Brett L.
Published:
Ann Arbor : ProQuest Dissertations & Theses, : 2016,
Description:
124 p.
Notes:
Source: Dissertation Abstracts International, Volume: 78-03(E), Section: B.
Contained By:
Dissertation Abstracts International78-03B(E).
Subject:
Analytical chemistry. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10149820
ISBN:
9781369049169
Analytical methods to enhance detection of anthropogenic radionuclides in environmental matrices.
Rosenberg, Brett L.
Analytical methods to enhance detection of anthropogenic radionuclides in environmental matrices.
- Ann Arbor : ProQuest Dissertations & Theses, 2016 - 124 p.
Source: Dissertation Abstracts International, Volume: 78-03(E), Section: B.
Thesis (Ph.D.)--Colorado State University, 2016.
The efficacy of methods that are used to detect radionuclides is dependent on the properties of the radionuclides and the matrices being analyzed. Gamma spectroscopy is an excellent tool for detecting very low quantities of a short-lived gamma-emitting radionuclide. However, as the probability of gamma ray emission decreases and the half-life increases, greater quantities of a radionuclide are required for detection by gamma spectroscopy. Since most transuranic actinides are usually not present in such quantities or concentrations in the environment, mass spectrometry is the preferred tool. For tritium, 90Sr, and other lower-Z elements that emit no easily detectable gamma rays, liquid scintillation counting is commonly used to measure the beta particles they emit. However, this methodology requires radiochemical extraction procedures to ensure a maximized ratio between signal and background. Nondestructive gamma spectroscopy was used to evaluate radiocesium content in soil and vegetation samples collected from the Fukushima prefecture exclusion zone in 2013 and 2014. Liquid scintillation counting was used for quantifying 3H in samples collected in 2013 and 90Sr in samples collected in 2013 and 2014. The radiocesium and 90Sr activities were found to have decreased from 2013 to 2014. Although 3H activities could be quantified in most samples, a sample from Chimeiji had a specific activity that statistically exceeded background (1.2 +/- 1.6 Bq mL -1); further investigation is required to ascertain if 3H is present within that sample. Reports generated by TEPCO were also evaluated; radiocesium ratios and 131I/132Te ratios calculated from the reports reveal the importance of considering counting statistics and spectroscopic interference when drawing conclusions about the presence of anthropogenic radionuclides in environmental samples.
ISBN: 9781369049169Subjects--Topical Terms:
3168300
Analytical chemistry.
Analytical methods to enhance detection of anthropogenic radionuclides in environmental matrices.
LDR
:03870nmm a2200313 4500
001
2119932
005
20170627090654.5
008
180830s2016 ||||||||||||||||| ||eng d
020
$a
9781369049169
035
$a
(MiAaPQ)AAI10149820
035
$a
AAI10149820
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Rosenberg, Brett L.
$3
3281833
245
1 0
$a
Analytical methods to enhance detection of anthropogenic radionuclides in environmental matrices.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2016
300
$a
124 p.
500
$a
Source: Dissertation Abstracts International, Volume: 78-03(E), Section: B.
500
$a
Adviser: Alexander Brandl.
502
$a
Thesis (Ph.D.)--Colorado State University, 2016.
520
$a
The efficacy of methods that are used to detect radionuclides is dependent on the properties of the radionuclides and the matrices being analyzed. Gamma spectroscopy is an excellent tool for detecting very low quantities of a short-lived gamma-emitting radionuclide. However, as the probability of gamma ray emission decreases and the half-life increases, greater quantities of a radionuclide are required for detection by gamma spectroscopy. Since most transuranic actinides are usually not present in such quantities or concentrations in the environment, mass spectrometry is the preferred tool. For tritium, 90Sr, and other lower-Z elements that emit no easily detectable gamma rays, liquid scintillation counting is commonly used to measure the beta particles they emit. However, this methodology requires radiochemical extraction procedures to ensure a maximized ratio between signal and background. Nondestructive gamma spectroscopy was used to evaluate radiocesium content in soil and vegetation samples collected from the Fukushima prefecture exclusion zone in 2013 and 2014. Liquid scintillation counting was used for quantifying 3H in samples collected in 2013 and 90Sr in samples collected in 2013 and 2014. The radiocesium and 90Sr activities were found to have decreased from 2013 to 2014. Although 3H activities could be quantified in most samples, a sample from Chimeiji had a specific activity that statistically exceeded background (1.2 +/- 1.6 Bq mL -1); further investigation is required to ascertain if 3H is present within that sample. Reports generated by TEPCO were also evaluated; radiocesium ratios and 131I/132Te ratios calculated from the reports reveal the importance of considering counting statistics and spectroscopic interference when drawing conclusions about the presence of anthropogenic radionuclides in environmental samples.
520
$a
Gamma spectroscopy was then applied to explore radiochemical separation techniques that can enhance detection of anthropogenic radionuclides, especially gamma-emitting actinides like 239Np shortly after a nuclear event. Ion specific extraction chromatography was found to be effective at minimizing spectroscopic interference from fission products, and addition of stable iodide carrier and a precipitating agent facilitated decreasing radioiodine activity within environmental samples. Extraction chromatography was found to reduce 131I interference by at least one order of magnitude, making it preferred for reducing 131I activity within an environmental sample. Extraction chromatography also avoids the potential of precipitating any analyte. The separation and measurement techniques utilized herein have effectively enhanced the ability to detect low-activity anthropogenic radionuclides; supplemental measurements gathered from the exclusion zone confirm the observed trends and prove the necessity of minimizing interference.
590
$a
School code: 0053.
650
4
$a
Analytical chemistry.
$3
3168300
650
4
$a
Soil sciences.
$3
2122699
650
4
$a
Nuclear chemistry.
$3
643077
690
$a
0486
690
$a
0481
690
$a
0738
710
2
$a
Colorado State University.
$b
Environmental and Radiological Health Sciences.
$3
3171224
773
0
$t
Dissertation Abstracts International
$g
78-03B(E).
790
$a
0053
791
$a
Ph.D.
792
$a
2016
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10149820
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9330550
電子資源
01.外借(書)_YB
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login