Hydrogen Effects on X80 Steel Mechanical Properties Measured by Tensile and Impact Testing.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Hydrogen Effects on X80 Steel Mechanical Properties Measured by Tensile and Impact Testing./
作者:
Li, Xuan.
出版者:
Ann Arbor : ProQuest Dissertations & Theses, : 2016,
面頁冊數:
53 p.
附註:
Source: Masters Abstracts International, Volume: 55-04.
Contained By:
Masters Abstracts International55-04(E).
標題:
Mechanical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10090261
ISBN:
9781339595894
Hydrogen Effects on X80 Steel Mechanical Properties Measured by Tensile and Impact Testing.
Li, Xuan.
Hydrogen Effects on X80 Steel Mechanical Properties Measured by Tensile and Impact Testing.
- Ann Arbor : ProQuest Dissertations & Theses, 2016 - 53 p.
Source: Masters Abstracts International, Volume: 55-04.
Thesis (M.S.M.E.)--University of South Florida, 2016.
The effect of hydrogen charging current density and tensile strain rate on the mechanical properties of X80 pipeline steel were investigated by slow strain rate test (SSRT), Charpy impact test, and scanning electron microscopy (SEM) in this thesis. The results show that both the ultimate tensile strength and elongation to failure of X80 steel were deteriorated significantly after charging with hydrogen. With a strain rate of 5 x 10-5 s-1, the relative tensile strength and plasticity loss of X80 steel had no significant change within the range of assumed hydrogen partial pressures at room temperature. At room temperature, X80 steel had no apparent variation in ultimate tensile strength and elongation, except at the strain rate of 10-6 s-1. Specimens obtained the greatest relative tensile strength loss and plasticity loss when strained at 10 -6 s-1 with a current density of 4.6 mA/cm2. The fracture morphology of two test groups of X80 steel exhibited significant brittle rupture when tested with dynamic hydrogen charging. The impact energy of X80 was not affected by hydrogen charging. Different current density also had no influence on the results of the impact test.
ISBN: 9781339595894Subjects--Topical Terms:
649730
Mechanical engineering.
Hydrogen Effects on X80 Steel Mechanical Properties Measured by Tensile and Impact Testing.
LDR
:02091nmm a2200289 4500
001
2119168
005
20170619080557.5
008
180830s2016 ||||||||||||||||| ||eng d
020
$a
9781339595894
035
$a
(MiAaPQ)AAI10090261
035
$a
AAI10090261
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Li, Xuan.
$3
1679978
245
1 0
$a
Hydrogen Effects on X80 Steel Mechanical Properties Measured by Tensile and Impact Testing.
260
1
$a
Ann Arbor :
$b
ProQuest Dissertations & Theses,
$c
2016
300
$a
53 p.
500
$a
Source: Masters Abstracts International, Volume: 55-04.
500
$a
Adviser: Alex A. Volinsky.
502
$a
Thesis (M.S.M.E.)--University of South Florida, 2016.
520
$a
The effect of hydrogen charging current density and tensile strain rate on the mechanical properties of X80 pipeline steel were investigated by slow strain rate test (SSRT), Charpy impact test, and scanning electron microscopy (SEM) in this thesis. The results show that both the ultimate tensile strength and elongation to failure of X80 steel were deteriorated significantly after charging with hydrogen. With a strain rate of 5 x 10-5 s-1, the relative tensile strength and plasticity loss of X80 steel had no significant change within the range of assumed hydrogen partial pressures at room temperature. At room temperature, X80 steel had no apparent variation in ultimate tensile strength and elongation, except at the strain rate of 10-6 s-1. Specimens obtained the greatest relative tensile strength loss and plasticity loss when strained at 10 -6 s-1 with a current density of 4.6 mA/cm2. The fracture morphology of two test groups of X80 steel exhibited significant brittle rupture when tested with dynamic hydrogen charging. The impact energy of X80 was not affected by hydrogen charging. Different current density also had no influence on the results of the impact test.
590
$a
School code: 0206.
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Materials science.
$3
543314
690
$a
0548
690
$a
0794
710
2
$a
University of South Florida.
$b
Mechanical Engineering.
$3
1680697
773
0
$t
Masters Abstracts International
$g
55-04(E).
790
$a
0206
791
$a
M.S.M.E.
792
$a
2016
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10090261
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9329786
電子資源
01.外借(書)_YB
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入