語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
A multiple modality localization alg...
~
Borgstadt, Justin A.
FindBook
Google Book
Amazon
博客來
A multiple modality localization algorithm for catheter interventions.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
A multiple modality localization algorithm for catheter interventions./
作者:
Borgstadt, Justin A.
面頁冊數:
125 p.
附註:
Source: Dissertation Abstracts International, Volume: 76-08(E), Section: B.
Contained By:
Dissertation Abstracts International76-08B(E).
標題:
Robotics. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3687555
ISBN:
9781321651638
A multiple modality localization algorithm for catheter interventions.
Borgstadt, Justin A.
A multiple modality localization algorithm for catheter interventions.
- 125 p.
Source: Dissertation Abstracts International, Volume: 76-08(E), Section: B.
Thesis (Ph.D.)--The University of Wisconsin - Madison, 2015.
Localization of steerable catheters in minimally invasive surgery is critical with respect to patient safety, surgeon manipulation, and procedural efficacy. While there are many potential benefits to patients including shorter recovery times, less tissue trauma, and lower infection rates than traditional surgeries, localization of surgical tools is still an area of much research. Current technology offers several sensory modalities including fluoroscopy, magnetic resonance imaging, computed tomography, and ultrasound. However, each system has drawbacks which do not provide a clear choice for best practice. This dissertation focuses on incorporating redundant commonplace surgical sensing technologies to reduce the likelihood of errors, failures, or inherent sensor characteristics possibly causing harm to the patient and/or surgeon while providing accurate localization. Dual particle filters are implemented using both a fluoroscopic-like stereo imaging system and an electromagnetic pose sensor for measurement updates in a prototype catheter test bed. A previously developed catheter model is modified and a rigorous calibration procedure is developed to increase accuracy in the particle filter outputs which are combined using a weighted average based on each filter's particle statistics. Experimental results implementing the combined particle filter multi-modal algorithm in feedback control validates the algorithms ability to provide accurate localization in a surgical setting while overcoming sensor limitations and possible failure modes.
ISBN: 9781321651638Subjects--Topical Terms:
519753
Robotics.
A multiple modality localization algorithm for catheter interventions.
LDR
:02483nmm a2200289 4500
001
2115916
005
20170417071255.5
008
180830s2015 ||||||||||||||||| ||eng d
020
$a
9781321651638
035
$a
(MiAaPQ)AAI3687555
035
$a
AAI3687555
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Borgstadt, Justin A.
$3
3277593
245
1 2
$a
A multiple modality localization algorithm for catheter interventions.
300
$a
125 p.
500
$a
Source: Dissertation Abstracts International, Volume: 76-08(E), Section: B.
500
$a
Advisers: Nicola J. Ferrier; Michael R. Zinn.
502
$a
Thesis (Ph.D.)--The University of Wisconsin - Madison, 2015.
520
$a
Localization of steerable catheters in minimally invasive surgery is critical with respect to patient safety, surgeon manipulation, and procedural efficacy. While there are many potential benefits to patients including shorter recovery times, less tissue trauma, and lower infection rates than traditional surgeries, localization of surgical tools is still an area of much research. Current technology offers several sensory modalities including fluoroscopy, magnetic resonance imaging, computed tomography, and ultrasound. However, each system has drawbacks which do not provide a clear choice for best practice. This dissertation focuses on incorporating redundant commonplace surgical sensing technologies to reduce the likelihood of errors, failures, or inherent sensor characteristics possibly causing harm to the patient and/or surgeon while providing accurate localization. Dual particle filters are implemented using both a fluoroscopic-like stereo imaging system and an electromagnetic pose sensor for measurement updates in a prototype catheter test bed. A previously developed catheter model is modified and a rigorous calibration procedure is developed to increase accuracy in the particle filter outputs which are combined using a weighted average based on each filter's particle statistics. Experimental results implementing the combined particle filter multi-modal algorithm in feedback control validates the algorithms ability to provide accurate localization in a surgical setting while overcoming sensor limitations and possible failure modes.
590
$a
School code: 0262.
650
4
$a
Robotics.
$3
519753
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Surgery.
$3
707153
690
$a
0771
690
$a
0548
690
$a
0576
710
2
$a
The University of Wisconsin - Madison.
$b
Mechanical Engineering.
$3
2094221
773
0
$t
Dissertation Abstracts International
$g
76-08B(E).
790
$a
0262
791
$a
Ph.D.
792
$a
2015
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3687555
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9326536
電子資源
01.外借(書)_YB
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入