語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Molybdenum Disulfide-Conducting Poly...
~
Jia, Hongxiang.
FindBook
Google Book
Amazon
博客來
Molybdenum Disulfide-Conducting Polymer Composite Structures for Electrochemical Biosensor Applications.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Molybdenum Disulfide-Conducting Polymer Composite Structures for Electrochemical Biosensor Applications./
作者:
Jia, Hongxiang.
面頁冊數:
81 p.
附註:
Source: Masters Abstracts International, Volume: 56-02.
Contained By:
Masters Abstracts International56-02(E).
標題:
Mechanical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10241623
ISBN:
9781369369311
Molybdenum Disulfide-Conducting Polymer Composite Structures for Electrochemical Biosensor Applications.
Jia, Hongxiang.
Molybdenum Disulfide-Conducting Polymer Composite Structures for Electrochemical Biosensor Applications.
- 81 p.
Source: Masters Abstracts International, Volume: 56-02.
Thesis (M.S.E.S.)--University of South Florida, 2016.
Lactic acid is widely existing in human bodies, animals and microorganisms. Recently, using biosensor to detect the concentration of lactic acid and diagnose disease have attracted great research and development interests. Nanocomposites is one of the best material used for biosensor because their wonderful conductivity, optical and electrochemical properties. In the study, MoS2 and polypyrrole (PPY) are used for the composite material electrode. To determine whether lactate oxidase (LOD) was helpful for the biosensor's detective properties, both PPY-MoS2 film with LOD and PPY-MoS2 film without LOD are being tested. The fourier transform infrared spectroscopy (FTIR) and Raman spectroscopic techniques have been used to understand the chemical bonds in the nanocomposite film. The X-ray diffraction (XRD) technique has been performed to understand the crystallographic structure of the MoS 2 -PPY film. The morphologies were confirmed by scanning electron microscopy (SEM). The UV-vis spectroscopy has been used to determine the band structure of composite film. Cyclic voltammetry (CV), chronoamperometry (CA), and electrochemical impedance spectroscopy (EIS) were used to analyze in different concentration of solution, under different scan rate to obtain stability and work efficiency. These results were compared with PPY-MoS2 film with and without lactate oxidase conditions. The chronoamperometric technique has been used to detect the concentration of lactic acid.
ISBN: 9781369369311Subjects--Topical Terms:
649730
Mechanical engineering.
Molybdenum Disulfide-Conducting Polymer Composite Structures for Electrochemical Biosensor Applications.
LDR
:02398nmm a2200289 4500
001
2079415
005
20170313112144.5
008
170521s2016 ||||||||||||||||| ||eng d
020
$a
9781369369311
035
$a
(MiAaPQ)AAI10241623
035
$a
AAI10241623
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Jia, Hongxiang.
$3
3195093
245
1 0
$a
Molybdenum Disulfide-Conducting Polymer Composite Structures for Electrochemical Biosensor Applications.
300
$a
81 p.
500
$a
Source: Masters Abstracts International, Volume: 56-02.
500
$a
Advisers: Manjo k. Ram; Ashok Kumar.
502
$a
Thesis (M.S.E.S.)--University of South Florida, 2016.
520
$a
Lactic acid is widely existing in human bodies, animals and microorganisms. Recently, using biosensor to detect the concentration of lactic acid and diagnose disease have attracted great research and development interests. Nanocomposites is one of the best material used for biosensor because their wonderful conductivity, optical and electrochemical properties. In the study, MoS2 and polypyrrole (PPY) are used for the composite material electrode. To determine whether lactate oxidase (LOD) was helpful for the biosensor's detective properties, both PPY-MoS2 film with LOD and PPY-MoS2 film without LOD are being tested. The fourier transform infrared spectroscopy (FTIR) and Raman spectroscopic techniques have been used to understand the chemical bonds in the nanocomposite film. The X-ray diffraction (XRD) technique has been performed to understand the crystallographic structure of the MoS 2 -PPY film. The morphologies were confirmed by scanning electron microscopy (SEM). The UV-vis spectroscopy has been used to determine the band structure of composite film. Cyclic voltammetry (CV), chronoamperometry (CA), and electrochemical impedance spectroscopy (EIS) were used to analyze in different concentration of solution, under different scan rate to obtain stability and work efficiency. These results were compared with PPY-MoS2 film with and without lactate oxidase conditions. The chronoamperometric technique has been used to detect the concentration of lactic acid.
590
$a
School code: 0206.
650
4
$a
Mechanical engineering.
$3
649730
650
4
$a
Nanotechnology.
$3
526235
650
4
$a
Biomechanics.
$3
548685
690
$a
0548
690
$a
0652
690
$a
0648
710
2
$a
University of South Florida.
$b
Mechanical Engineering.
$3
1680697
773
0
$t
Masters Abstracts International
$g
56-02(E).
790
$a
0206
791
$a
M.S.E.S.
792
$a
2016
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10241623
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9312293
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入