Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Chloramination and corrosion: Case s...
~
Heberling, Jason A.
Linked to FindBook
Google Book
Amazon
博客來
Chloramination and corrosion: Case studies, utility experience, and statistical comparisons with chlorination.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Chloramination and corrosion: Case studies, utility experience, and statistical comparisons with chlorination./
Author:
Heberling, Jason A.
Description:
135 p.
Notes:
Source: Dissertation Abstracts International, Volume: 76-01(E), Section: B.
Contained By:
Dissertation Abstracts International76-01B(E).
Subject:
Civil engineering. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3634552
ISBN:
9781321151626
Chloramination and corrosion: Case studies, utility experience, and statistical comparisons with chlorination.
Heberling, Jason A.
Chloramination and corrosion: Case studies, utility experience, and statistical comparisons with chlorination.
- 135 p.
Source: Dissertation Abstracts International, Volume: 76-01(E), Section: B.
Thesis (Ph.D.)--The University of Alabama at Birmingham, 2014.
The United States Environmental Protection Agency (EPA) began implementing the Stage 2 Disinfectant By-products (DBP) Rule (Stage 2) in 2012. The purpose of this regulation is to protect water utility customers from potentially harmful DBP's, most importantly, total trihalomethanes (TTHM) and haloacetic acids (HAA). DBP's have been directly linked to health problems, especially bladder cancer. Regulated DBP's are formed by the chemical reaction of chlorine and naturally occurring organic matter. Chloramines do not produce TTHM's and HAA's and water utilities have used chloramines in place of chlorine in an attempt to meet Stage 2 rules. However, a possible problem of introducing chloramines to a distribution system is a potential increase of metal residuals, particularly lead. Any process or chemical that increases lead corrosion could raise lead concentrations in drinking water supplies leading to health concerns.
ISBN: 9781321151626Subjects--Topical Terms:
860360
Civil engineering.
Chloramination and corrosion: Case studies, utility experience, and statistical comparisons with chlorination.
LDR
:03393nmm a2200313 4500
001
2078647
005
20161129073731.5
008
170521s2014 ||||||||||||||||| ||eng d
020
$a
9781321151626
035
$a
(MiAaPQ)AAI3634552
035
$a
AAI3634552
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Heberling, Jason A.
$3
3194244
245
1 0
$a
Chloramination and corrosion: Case studies, utility experience, and statistical comparisons with chlorination.
300
$a
135 p.
500
$a
Source: Dissertation Abstracts International, Volume: 76-01(E), Section: B.
500
$a
Adviser: Robert W. Peters.
502
$a
Thesis (Ph.D.)--The University of Alabama at Birmingham, 2014.
520
$a
The United States Environmental Protection Agency (EPA) began implementing the Stage 2 Disinfectant By-products (DBP) Rule (Stage 2) in 2012. The purpose of this regulation is to protect water utility customers from potentially harmful DBP's, most importantly, total trihalomethanes (TTHM) and haloacetic acids (HAA). DBP's have been directly linked to health problems, especially bladder cancer. Regulated DBP's are formed by the chemical reaction of chlorine and naturally occurring organic matter. Chloramines do not produce TTHM's and HAA's and water utilities have used chloramines in place of chlorine in an attempt to meet Stage 2 rules. However, a possible problem of introducing chloramines to a distribution system is a potential increase of metal residuals, particularly lead. Any process or chemical that increases lead corrosion could raise lead concentrations in drinking water supplies leading to health concerns.
520
$a
The following dissertation examines iron and lead corrosion data collected from a study performed for the Birmingham Water Works Board (BWWB); Birmingham, Alabama. The study was conducted to determine if the BWWB could switch their primary disinfectant from chlorine to chloramines, in an effort to combat DBP's, without contamination of drinking water from increased lead and iron residuals. Statistical comparisons are made between chloraminated and chlorinated drinking water collected from a flow-through rack constructed by the BWWB. This rack was comprised of lead pipes, cast iron pipes, and brass fixtures. Statistical analyses are performed on the data to compare and contrast corrosion potential of chlorinated and chloraminated drinking water treated with corrosion inhibitors.
520
$a
The results of this study showed that chloramines, coupled with an orthophosphate based corrosion inhibitor did not increase metal residuals in cast iron pipes, lead pipes, and brass fixtures. Prolonged use of orthophosphates in the flow-through resulted in the continued drop of lead and cast iron residuals. However, one of the most important findings of this study was that corrosion inhibitors, which contain polyphosphates, do not reduce but actually increase water corrosivity in lead bearing features. Utilities with distribution systems that contain any lead bearing features run great risks for high lead residuals when using polyphosphates or polyphosphate blends for corrosion control.
590
$a
School code: 0005.
650
4
$a
Civil engineering.
$3
860360
650
4
$a
Environmental engineering.
$3
548583
650
4
$a
Water resources management.
$3
794747
690
$a
0543
690
$a
0775
690
$a
0595
710
2
$a
The University of Alabama at Birmingham.
$b
Civil Engineering.
$3
3194245
773
0
$t
Dissertation Abstracts International
$g
76-01B(E).
790
$a
0005
791
$a
Ph.D.
792
$a
2014
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3634552
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9311515
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login