Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Data-Driven Motion Detection and Cha...
~
Shaw, John Dennis.
Linked to FindBook
Google Book
Amazon
博客來
Data-Driven Motion Detection and Characterization in PET Brain Scans Using List Mode.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Data-Driven Motion Detection and Characterization in PET Brain Scans Using List Mode./
Author:
Shaw, John Dennis.
Description:
78 p.
Notes:
Source: Masters Abstracts International, Volume: 55-04.
Contained By:
Masters Abstracts International55-04(E).
Subject:
Medical imaging. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10109364
ISBN:
9781339726502
Data-Driven Motion Detection and Characterization in PET Brain Scans Using List Mode.
Shaw, John Dennis.
Data-Driven Motion Detection and Characterization in PET Brain Scans Using List Mode.
- 78 p.
Source: Masters Abstracts International, Volume: 55-04.
Thesis (M.S.)--Duke University, 2016.
Head motion during a Positron Emission Tomography (PET) brain scan can considerably degrade image quality. External motion-tracking devices have proven successful in minimizing this effect, but the associated time, maintenance, and workflow changes inhibit their widespread clinical use. List-mode PET acquisition allows for the retroactive analysis of coincidence events on any time scale throughout a scan, and therefore potentially offers a data-driven motion detection and characterization technique. An algorithm was developed to parse list-mode data, divide the full acquisition into short scan intervals, and calculate the line-of-response (LOR) midpoint average for each interval. These LOR midpoint averages, known as "radioactivity centroids," were presumed to represent the center of the radioactivity distribution in the scanner, and it was thought that changes in this metric over time would correspond to intra-scan motion.
ISBN: 9781339726502Subjects--Topical Terms:
3172799
Medical imaging.
Data-Driven Motion Detection and Characterization in PET Brain Scans Using List Mode.
LDR
:02744nmm a2200277 4500
001
2075859
005
20161028152009.5
008
170521s2016 ||||||||||||||||| ||eng d
020
$a
9781339726502
035
$a
(MiAaPQ)AAI10109364
035
$a
AAI10109364
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Shaw, John Dennis.
$3
3191280
245
1 0
$a
Data-Driven Motion Detection and Characterization in PET Brain Scans Using List Mode.
300
$a
78 p.
500
$a
Source: Masters Abstracts International, Volume: 55-04.
500
$a
Adviser: Timothy G. Turkington.
502
$a
Thesis (M.S.)--Duke University, 2016.
520
$a
Head motion during a Positron Emission Tomography (PET) brain scan can considerably degrade image quality. External motion-tracking devices have proven successful in minimizing this effect, but the associated time, maintenance, and workflow changes inhibit their widespread clinical use. List-mode PET acquisition allows for the retroactive analysis of coincidence events on any time scale throughout a scan, and therefore potentially offers a data-driven motion detection and characterization technique. An algorithm was developed to parse list-mode data, divide the full acquisition into short scan intervals, and calculate the line-of-response (LOR) midpoint average for each interval. These LOR midpoint averages, known as "radioactivity centroids," were presumed to represent the center of the radioactivity distribution in the scanner, and it was thought that changes in this metric over time would correspond to intra-scan motion.
520
$a
Several scans were taken of the 3D Hoffman brain phantom on a GE Discovery IQ PET/CT scanner to test the ability of the radioactivity to indicate intra-scan motion. Each scan incrementally surveyed motion in a different degree of freedom (2 translational and 2 rotational). The radioactivity centroids calculated from these scans correlated linearly to phantom positions/orientations. Centroid measurements over 1-second intervals performed on scans with ~1mCi of activity in the center of the field of view had standard deviations of 0.026 cm in the x- and y-dimensions and 0.020 cm in the z-dimension, which demonstrates high precision and repeatability in this metric. Radioactivity centroids are thus shown to successfully represent discrete motions on the submillimeter scale. It is also shown that while the radioactivity centroid can precisely indicate the amount of motion during an acquisition, it fails to distinguish what type of motion occurred.
590
$a
School code: 0066.
650
4
$a
Medical imaging.
$3
3172799
690
$a
0574
710
2
$a
Duke University.
$b
Medical Physics.
$3
2101548
773
0
$t
Masters Abstracts International
$g
55-04(E).
790
$a
0066
791
$a
M.S.
792
$a
2016
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=10109364
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9308727
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login