Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
4D flow mri post-processing strategi...
~
Schrauben, Eric Mathew.
Linked to FindBook
Google Book
Amazon
博客來
4D flow mri post-processing strategies for neuropathologies.
Record Type:
Electronic resources : Monograph/item
Title/Author:
4D flow mri post-processing strategies for neuropathologies./
Author:
Schrauben, Eric Mathew.
Description:
128 p.
Notes:
Source: Dissertation Abstracts International, Volume: 76-09(E), Section: B.
Contained By:
Dissertation Abstracts International76-09B(E).
Subject:
Medical imaging. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3702037
ISBN:
9781321730678
4D flow mri post-processing strategies for neuropathologies.
Schrauben, Eric Mathew.
4D flow mri post-processing strategies for neuropathologies.
- 128 p.
Source: Dissertation Abstracts International, Volume: 76-09(E), Section: B.
Thesis (Ph.D.)--The University of Wisconsin - Madison, 2015.
4D flow MRI allows for the measurement of a dynamic 3D velocity vector field. Blood flow velocities in large vascular territories can be qualitatively visualized with the added benefit of quantitative probing. Within cranial pathologies theorized to have vascular-based contributions or effects, 4D flow MRI provides a unique platform for comprehensive assessment of hemodynamic parameters. Targeted blood flow derived measurements, such as flow rate, pulsatility, retrograde flow, or wall shear stress may provide insight into the onset or characterization of more complex neuropathologies. Therefore, the thorough assessment of each parameter within the context of a given disease has important medical implications.
ISBN: 9781321730678Subjects--Topical Terms:
3172799
Medical imaging.
4D flow mri post-processing strategies for neuropathologies.
LDR
:03262nmm a2200313 4500
001
2064271
005
20151109142631.5
008
170521s2015 ||||||||||||||||| ||eng d
020
$a
9781321730678
035
$a
(MiAaPQ)AAI3702037
035
$a
AAI3702037
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Schrauben, Eric Mathew.
$3
3178837
245
1 0
$a
4D flow mri post-processing strategies for neuropathologies.
300
$a
128 p.
500
$a
Source: Dissertation Abstracts International, Volume: 76-09(E), Section: B.
500
$a
Adviser: Oliver Wieben.
502
$a
Thesis (Ph.D.)--The University of Wisconsin - Madison, 2015.
520
$a
4D flow MRI allows for the measurement of a dynamic 3D velocity vector field. Blood flow velocities in large vascular territories can be qualitatively visualized with the added benefit of quantitative probing. Within cranial pathologies theorized to have vascular-based contributions or effects, 4D flow MRI provides a unique platform for comprehensive assessment of hemodynamic parameters. Targeted blood flow derived measurements, such as flow rate, pulsatility, retrograde flow, or wall shear stress may provide insight into the onset or characterization of more complex neuropathologies. Therefore, the thorough assessment of each parameter within the context of a given disease has important medical implications.
520
$a
Not surprisingly, the last decade has seen rapid growth in the use of 4D flow MRI. Data acquisition sequences are available to researchers on all major scanner platforms. However, the use has been limited mostly to small research trials. One major reason that has hindered the more widespread use and application in larger clinical trials is the complexity of the post-processing tasks and the lack of adequate tools for these tasks. Post-processing of 4D flow MRI must be semi-automated, fast, user-independent, robust, and reliably consistent for use in a clinical setting, within large patient studies, or across a multicenter trial. Development of proper post-processing methods coupled with systematic investigation in normal and patient populations pushes 4D flow MRI closer to clinical realization while elucidating potential underlying neuropathological origins.
520
$a
Within this framework, the work in this thesis assesses venous flow reproducibility and internal consistency in a healthy population. A preliminary analysis of venous flow parameters in healthy controls and multiple sclerosis patients is performed in a large study employing 4D flow MRI. These studies are performed in the context of the chronic cerebrospinal venous insufficiency hypothesis. Additionally, a double-gated flow acquisition and reconstruction scheme demonstrates respiratory-induced changes in internal jugular vein flow. Finally, a semi-automated intracranial vessel segmentation and flow parameter measurement software tool for fast and consistent 4D flow post-processing analysis is developed, validated, and exhibited an in-vivo.
590
$a
School code: 0262.
650
4
$a
Medical imaging.
$3
3172799
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Physics.
$3
516296
690
$a
0574
690
$a
0541
690
$a
0605
710
2
$a
The University of Wisconsin - Madison.
$b
Medical Physics.
$3
2097834
773
0
$t
Dissertation Abstracts International
$g
76-09B(E).
790
$a
0262
791
$a
Ph.D.
792
$a
2015
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3702037
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9296929
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login