Tomographic image reconstruction: Im...
~
Xu, Shiyu.
FindBook
Google Book
Amazon
博客來
Tomographic image reconstruction: Implementation, optimization and comparison in digital breast tomosynthesis.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Tomographic image reconstruction: Implementation, optimization and comparison in digital breast tomosynthesis./
作者:
Xu, Shiyu.
面頁冊數:
144 p.
附註:
Source: Dissertation Abstracts International, Volume: 76-07(E), Section: B.
Contained By:
Dissertation Abstracts International76-07B(E).
標題:
Medical imaging. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3684719
ISBN:
9781321600612
Tomographic image reconstruction: Implementation, optimization and comparison in digital breast tomosynthesis.
Xu, Shiyu.
Tomographic image reconstruction: Implementation, optimization and comparison in digital breast tomosynthesis.
- 144 p.
Source: Dissertation Abstracts International, Volume: 76-07(E), Section: B.
Thesis (Ph.D.)--Southern Illinois University at Carbondale, 2014.
This item must not be sold to any third party vendors.
Conventional 2D mammography was the most effective approach to detecting early stage breast cancer in the past decades of years. Tomosynthetic breast imaging is a potentially more valuable 3D technique for breast cancer detection. The limitations of current tomosynthesis systems include a longer scanning time than a conventional digital X-ray modality and a low spatial resolution due to the movement of the single X-ray source. Dr.Otto Zhou's group proposed the concept of stationary digital breast tomosynthesis (s-DBT) using a Carbon Nano-Tube (CNT) based X-ray source array. Instead of mechanically moving a single X-ray tube, s-DBT applies a stationary X-ray source array, which generates X-ray beams from different view angles by electronically activating the individual source prepositioned at the corresponding view angle, therefore eliminating the focal spot motion blurring from sources. The scanning speed is determined only by the detector readout time and the number of sources regardless of the angular coverage spans, such that the blur from patient's motion can be reduced due to the quick scan. S-DBT is potentially a promising modality to improve the early breast cancer detection by providing decent image quality with fast scan and low radiation dose. DBT system acquires a limited number of noisy 2D projections over a limited angular range and then mathematically reconstructs a 3D breast. 3D reconstruction is faced with the challenges of cone-beam and flat-panel geometry, highly incomplete sampling and huge reconstructed volume. In this research, we investigated several representative reconstruction methods such as Filtered backprojection method (FBP), Simultaneous algebraic reconstruction technique (SART) and Maximum likelihood (ML). We also compared our proposed statistical iterative reconstruction (IR) with particular prior and computational technique to these representative methods. Of all available reconstruction methods in this research, our proposed statistical IR appears particularly promising since it provides the flexibility of accurate physical noise modeling and geometric system description. In the following chapters, we present multiple key techniques of statistical IR to tomosynthesis imaging data to demonstrate significant image quality improvement over conventional techniques. These techniques include the physical modeling with a local voxel-pair based prior with the flexibility in its parameters to fine-tune image quality, the pre-computed parameter κ incorporated with the prior to remove the data dependence and to achieve a predictable resolution property, an effective ray-driven technique to compute the forward and backprojection and an over-sampled ray-driven method to perform high resolution reconstruction with a practical region of interest (ROI) technique. In addition, to solve the estimation problem with a fast computation, we also present a semi-quantitative method to optimize the relaxation parameter in a relaxed order-subsets framework and an optimization transfer based algorithm framework which potentially allows less iterations to achieve an acceptable convergence. The phantom data is acquired with the s-DBT prototype system to assess the performance of these particular techniques and compare our proposed method to those representatives. The value of IR is demonstrated in improving the detectability of low contrast and tiny micro-calcification, in reducing cross plane artifacts, in improving resolution and lowering noise in reconstructed images. In particular, noise power spectrum analysis (NPS) indicates a superior noise spectral property of our proposed statistical IR, especially in the high frequency range. With the decent noise property, statistical IR also provides a remarkable reconstruction MTF in general and in different areas within a focus plane. Although computational load remains a significant challenge for practical development, combined with the advancing computational techniques such as graphic computing, the superior image quality provided by statistical IR will be realized to benefit the diagnostics in real clinical applications.
ISBN: 9781321600612Subjects--Topical Terms:
3172799
Medical imaging.
Tomographic image reconstruction: Implementation, optimization and comparison in digital breast tomosynthesis.
LDR
:05128nmm a2200277 4500
001
2059991
005
20150822105425.5
008
170521s2014 ||||||||||||||||| ||eng d
020
$a
9781321600612
035
$a
(MiAaPQ)AAI3684719
035
$a
AAI3684719
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Xu, Shiyu.
$3
3174130
245
1 0
$a
Tomographic image reconstruction: Implementation, optimization and comparison in digital breast tomosynthesis.
300
$a
144 p.
500
$a
Source: Dissertation Abstracts International, Volume: 76-07(E), Section: B.
500
$a
Adviser: Ying Chen.
502
$a
Thesis (Ph.D.)--Southern Illinois University at Carbondale, 2014.
506
$a
This item must not be sold to any third party vendors.
520
$a
Conventional 2D mammography was the most effective approach to detecting early stage breast cancer in the past decades of years. Tomosynthetic breast imaging is a potentially more valuable 3D technique for breast cancer detection. The limitations of current tomosynthesis systems include a longer scanning time than a conventional digital X-ray modality and a low spatial resolution due to the movement of the single X-ray source. Dr.Otto Zhou's group proposed the concept of stationary digital breast tomosynthesis (s-DBT) using a Carbon Nano-Tube (CNT) based X-ray source array. Instead of mechanically moving a single X-ray tube, s-DBT applies a stationary X-ray source array, which generates X-ray beams from different view angles by electronically activating the individual source prepositioned at the corresponding view angle, therefore eliminating the focal spot motion blurring from sources. The scanning speed is determined only by the detector readout time and the number of sources regardless of the angular coverage spans, such that the blur from patient's motion can be reduced due to the quick scan. S-DBT is potentially a promising modality to improve the early breast cancer detection by providing decent image quality with fast scan and low radiation dose. DBT system acquires a limited number of noisy 2D projections over a limited angular range and then mathematically reconstructs a 3D breast. 3D reconstruction is faced with the challenges of cone-beam and flat-panel geometry, highly incomplete sampling and huge reconstructed volume. In this research, we investigated several representative reconstruction methods such as Filtered backprojection method (FBP), Simultaneous algebraic reconstruction technique (SART) and Maximum likelihood (ML). We also compared our proposed statistical iterative reconstruction (IR) with particular prior and computational technique to these representative methods. Of all available reconstruction methods in this research, our proposed statistical IR appears particularly promising since it provides the flexibility of accurate physical noise modeling and geometric system description. In the following chapters, we present multiple key techniques of statistical IR to tomosynthesis imaging data to demonstrate significant image quality improvement over conventional techniques. These techniques include the physical modeling with a local voxel-pair based prior with the flexibility in its parameters to fine-tune image quality, the pre-computed parameter κ incorporated with the prior to remove the data dependence and to achieve a predictable resolution property, an effective ray-driven technique to compute the forward and backprojection and an over-sampled ray-driven method to perform high resolution reconstruction with a practical region of interest (ROI) technique. In addition, to solve the estimation problem with a fast computation, we also present a semi-quantitative method to optimize the relaxation parameter in a relaxed order-subsets framework and an optimization transfer based algorithm framework which potentially allows less iterations to achieve an acceptable convergence. The phantom data is acquired with the s-DBT prototype system to assess the performance of these particular techniques and compare our proposed method to those representatives. The value of IR is demonstrated in improving the detectability of low contrast and tiny micro-calcification, in reducing cross plane artifacts, in improving resolution and lowering noise in reconstructed images. In particular, noise power spectrum analysis (NPS) indicates a superior noise spectral property of our proposed statistical IR, especially in the high frequency range. With the decent noise property, statistical IR also provides a remarkable reconstruction MTF in general and in different areas within a focus plane. Although computational load remains a significant challenge for practical development, combined with the advancing computational techniques such as graphic computing, the superior image quality provided by statistical IR will be realized to benefit the diagnostics in real clinical applications.
590
$a
School code: 0209.
650
4
$a
Medical imaging.
$3
3172799
690
$a
0574
710
2
$a
Southern Illinois University at Carbondale.
$b
Electrical and Computer Engineering.
$3
1030566
773
0
$t
Dissertation Abstracts International
$g
76-07B(E).
790
$a
0209
791
$a
Ph.D.
792
$a
2014
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3684719
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9292649
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入