語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
A Four-Dimensional Image Reconstruct...
~
Mathews, Aswin John.
FindBook
Google Book
Amazon
博客來
A Four-Dimensional Image Reconstruction Framework for PET under Arbitrary Geometries.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
A Four-Dimensional Image Reconstruction Framework for PET under Arbitrary Geometries./
作者:
Mathews, Aswin John.
面頁冊數:
146 p.
附註:
Source: Dissertation Abstracts International, Volume: 76-04(E), Section: B.
Contained By:
Dissertation Abstracts International76-04B(E).
標題:
Electrical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3646851
ISBN:
9781321369038
A Four-Dimensional Image Reconstruction Framework for PET under Arbitrary Geometries.
Mathews, Aswin John.
A Four-Dimensional Image Reconstruction Framework for PET under Arbitrary Geometries.
- 146 p.
Source: Dissertation Abstracts International, Volume: 76-04(E), Section: B.
Thesis (Ph.D.)--Washington University in St. Louis, 2014.
This item must not be sold to any third party vendors.
Positron Emission Tomography (PET) is a functional imaging modality with applications ranging from the treatment of cancer, studying neurological diseases and disease models. Virtual-Pinhole PET technology improves the image quality in terms of resolution and contrast recovery. The technology calls for having a detector with smaller crystals placed near a region of interest in a conventional whole-body PET scanner. The improvement is from the higher spatial sampling of the imaging area near the detector. A prototype half-ring PET insert built to study head-and-neck cancer imaging was extended to breast cancer imaging. We have built a prototype half-ring PET insert for head-and-neck cancer imaging applications. In the first half of this work, we extend the use of the insert to breast imaging and show that such a system provides high resolution images of breast and axillary lymph nodes while maintaining the full imaging field of view capability of a clinical PET scanner.
ISBN: 9781321369038Subjects--Topical Terms:
649834
Electrical engineering.
A Four-Dimensional Image Reconstruction Framework for PET under Arbitrary Geometries.
LDR
:03861nmm a2200301 4500
001
2059978
005
20150822105425.5
008
170521s2014 ||||||||||||||||| ||eng d
020
$a
9781321369038
035
$a
(MiAaPQ)AAI3646851
035
$a
AAI3646851
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Mathews, Aswin John.
$3
3174118
245
1 2
$a
A Four-Dimensional Image Reconstruction Framework for PET under Arbitrary Geometries.
300
$a
146 p.
500
$a
Source: Dissertation Abstracts International, Volume: 76-04(E), Section: B.
500
$a
Adviser: Joseph A. O'Sullivan.
502
$a
Thesis (Ph.D.)--Washington University in St. Louis, 2014.
506
$a
This item must not be sold to any third party vendors.
520
$a
Positron Emission Tomography (PET) is a functional imaging modality with applications ranging from the treatment of cancer, studying neurological diseases and disease models. Virtual-Pinhole PET technology improves the image quality in terms of resolution and contrast recovery. The technology calls for having a detector with smaller crystals placed near a region of interest in a conventional whole-body PET scanner. The improvement is from the higher spatial sampling of the imaging area near the detector. A prototype half-ring PET insert built to study head-and-neck cancer imaging was extended to breast cancer imaging. We have built a prototype half-ring PET insert for head-and-neck cancer imaging applications. In the first half of this work, we extend the use of the insert to breast imaging and show that such a system provides high resolution images of breast and axillary lymph nodes while maintaining the full imaging field of view capability of a clinical PET scanner.
520
$a
We are focused on designing unconventional PET geometries for specific applications. A general purpose 4D PET reconstruction framework was created to estimate the radionuclide uptake in the subject. Quantitative estimation in PET requires precise modeling of PET physics. Data acquired in a PET scanner is well modeled as a Poisson counting process. Reconstruction given the forward model is implemented using MAP-OSEM. The framework is capable of reconstructing PET data under arbitrary position of the detector elements and different crystal sizes. A novel symmetry finding algorithm is created to reduce the system matrix size, without loss of resolution. The framework motivates investigation into different PET system geometries for different applications, as well as optimizing the design of PET systems. A generalized normalization procedure was developed to model unknown components. The programs are parallelized using OpenMP and MPI to run on small workstations as well as super-computing clusters. The performance of our reconstruction framework is presented through four novel and unconventional PET systems, each designed specifically for a different geometry. The Virtual-Pinhole half-ring system is a half-ring insert integrated into a Siemens Biograph-40, for head and neck imaging. The Flat-panel system is a modular insert system integrated into the Biograph-40, designed for breast cancer imaging. The MicroInsert II is the second generation full ring insert device, integrated into the MicroPET scanner to improve the resolution and contrast recovery of the MicroPET scanner. The Plant PET system is a PET system designed to image plants vertically, and integrated into a plant growth chamber. The improvement in speed/memory from symmetry finding is as high as a factor of 50 in some cases. Further improvements to the framework and state of the field are also discussed.
590
$a
School code: 0252.
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Medical imaging.
$3
3172799
690
$a
0544
690
$a
0574
710
2
$a
Washington University in St. Louis.
$b
Electrical Engineering.
$3
1679873
773
0
$t
Dissertation Abstracts International
$g
76-04B(E).
790
$a
0252
791
$a
Ph.D.
792
$a
2014
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3646851
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9292636
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入