語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Intervertebral disc structure and me...
~
Yoder, Jonathon Henry.
FindBook
Google Book
Amazon
博客來
Intervertebral disc structure and mechanical function under physiological loading quantified non-invasively utilizing MRI and image registration.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Intervertebral disc structure and mechanical function under physiological loading quantified non-invasively utilizing MRI and image registration./
作者:
Yoder, Jonathon Henry.
面頁冊數:
157 p.
附註:
Source: Dissertation Abstracts International, Volume: 76-01(E), Section: B.
Contained By:
Dissertation Abstracts International76-01B(E).
標題:
Biomechanics. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3634223
ISBN:
9781321144871
Intervertebral disc structure and mechanical function under physiological loading quantified non-invasively utilizing MRI and image registration.
Yoder, Jonathon Henry.
Intervertebral disc structure and mechanical function under physiological loading quantified non-invasively utilizing MRI and image registration.
- 157 p.
Source: Dissertation Abstracts International, Volume: 76-01(E), Section: B.
Thesis (Ph.D.)--University of Pennsylvania, 2014.
This item must not be sold to any third party vendors.
The intervertebral discs (IVD) functions to permit motion, distribute load, and dissipate energy in the spine. It performs these functions through its heterogeneous structural organization and biochemical composition consisting of several tissue substructures: the central gelatinous nucleus pulposus (NP), the surrounding fiber reinforced layered annulus fibrosus (AF), and the cartilaginous endplates (CEP) that are positioned between the NP and vertebral endplates. Each tissue contributes individually to overall disc mechanics and by interacting with adjacent tissues. Disruption of the disc's tissues through aging, degeneration, or tear will not only alter the affected tissue mechanical properties, but also the mechanical behavior of adjacent tissues and, ultimately, overall disc segment function. Thus, there is a need to measure disc tissue and segment mechanics in the intact disc so that interactions between substructures are not disrupted. Such measurements would be valuable to study mechanisms of disc function and degeneration, and develop and evaluate surgical procedures and therapeutic implants. The objectives of this study were to develop, validate, and apply methods to visualize and quantify IVD substructure geometry and track internal deformations for intact human discs under axial compression. The CEP and AF were visualized through MRI parameter mapping and image sequence optimization for ideal contrast. High-resolution images enabled geometric measurements. Axial compression was performed using a custom-built loading device that permitted long relaxation times outside of the MRI, 300 microm isotropic resolution images were acquired, and image registration methods applied to measure 3D internal strain. In conclusion, new methods to visualize and quantify CEP thickness, annular tear detection and geometric quantification, and non-invasively measure 3D internal disc strains were established. No correlation was found between CEP thickness and disc level; however the periphery was significantly thicker compared to central locations. Clear distinction of adjacent AF lamellae enabled annular tear detection and detailed geometric quantification. Annular tears demonstrated "non-classic" geometry through interconnecting radial, circumferential, and perinuclear formations. Regional strain inhomogeneity was observed qualitatively and quantitatively. Variation in strain magnitudes might be explained by geometry in axial and circumferential strain while peak radial strain in the posterior AF may have important implications for disc herniation.
ISBN: 9781321144871Subjects--Topical Terms:
548685
Biomechanics.
Intervertebral disc structure and mechanical function under physiological loading quantified non-invasively utilizing MRI and image registration.
LDR
:03701nmm a2200313 4500
001
2059964
005
20150822105424.5
008
170521s2014 ||||||||||||||||| ||eng d
020
$a
9781321144871
035
$a
(MiAaPQ)AAI3634223
035
$a
AAI3634223
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Yoder, Jonathon Henry.
$3
3174098
245
1 0
$a
Intervertebral disc structure and mechanical function under physiological loading quantified non-invasively utilizing MRI and image registration.
300
$a
157 p.
500
$a
Source: Dissertation Abstracts International, Volume: 76-01(E), Section: B.
500
$a
Adviser: Dawn M. Elliott.
502
$a
Thesis (Ph.D.)--University of Pennsylvania, 2014.
506
$a
This item must not be sold to any third party vendors.
506
$a
This item must not be added to any third party search indexes.
520
$a
The intervertebral discs (IVD) functions to permit motion, distribute load, and dissipate energy in the spine. It performs these functions through its heterogeneous structural organization and biochemical composition consisting of several tissue substructures: the central gelatinous nucleus pulposus (NP), the surrounding fiber reinforced layered annulus fibrosus (AF), and the cartilaginous endplates (CEP) that are positioned between the NP and vertebral endplates. Each tissue contributes individually to overall disc mechanics and by interacting with adjacent tissues. Disruption of the disc's tissues through aging, degeneration, or tear will not only alter the affected tissue mechanical properties, but also the mechanical behavior of adjacent tissues and, ultimately, overall disc segment function. Thus, there is a need to measure disc tissue and segment mechanics in the intact disc so that interactions between substructures are not disrupted. Such measurements would be valuable to study mechanisms of disc function and degeneration, and develop and evaluate surgical procedures and therapeutic implants. The objectives of this study were to develop, validate, and apply methods to visualize and quantify IVD substructure geometry and track internal deformations for intact human discs under axial compression. The CEP and AF were visualized through MRI parameter mapping and image sequence optimization for ideal contrast. High-resolution images enabled geometric measurements. Axial compression was performed using a custom-built loading device that permitted long relaxation times outside of the MRI, 300 microm isotropic resolution images were acquired, and image registration methods applied to measure 3D internal strain. In conclusion, new methods to visualize and quantify CEP thickness, annular tear detection and geometric quantification, and non-invasively measure 3D internal disc strains were established. No correlation was found between CEP thickness and disc level; however the periphery was significantly thicker compared to central locations. Clear distinction of adjacent AF lamellae enabled annular tear detection and detailed geometric quantification. Annular tears demonstrated "non-classic" geometry through interconnecting radial, circumferential, and perinuclear formations. Regional strain inhomogeneity was observed qualitatively and quantitatively. Variation in strain magnitudes might be explained by geometry in axial and circumferential strain while peak radial strain in the posterior AF may have important implications for disc herniation.
590
$a
School code: 0175.
650
4
$a
Biomechanics.
$3
548685
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Medical imaging.
$3
3172799
690
$a
0648
690
$a
0541
690
$a
0574
710
2
$a
University of Pennsylvania.
$b
Mechanical Engineering and Applied Mechanics.
$3
3174099
773
0
$t
Dissertation Abstracts International
$g
76-01B(E).
790
$a
0175
791
$a
Ph.D.
792
$a
2014
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3634223
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9292622
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入