語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Optimization of Focused Ultrasound a...
~
Almekkawy, Mohamed Khaled Ibrahim.
FindBook
Google Book
Amazon
博客來
Optimization of Focused Ultrasound and Image Based Modeling in Image Guided Interventions.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Optimization of Focused Ultrasound and Image Based Modeling in Image Guided Interventions./
作者:
Almekkawy, Mohamed Khaled Ibrahim.
面頁冊數:
141 p.
附註:
Source: Dissertation Abstracts International, Volume: 75-11(E), Section: B.
Contained By:
Dissertation Abstracts International75-11B(E).
標題:
Electrical engineering. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3630208
ISBN:
9781321080155
Optimization of Focused Ultrasound and Image Based Modeling in Image Guided Interventions.
Almekkawy, Mohamed Khaled Ibrahim.
Optimization of Focused Ultrasound and Image Based Modeling in Image Guided Interventions.
- 141 p.
Source: Dissertation Abstracts International, Volume: 75-11(E), Section: B.
Thesis (Ph.D.)--University of Minnesota, 2014.
This item must not be sold to any third party vendors.
Image-guided high intensity focused ultrasound (HIFU) is becoming increasingly accepted as a form of noninvasive ablative therapy for the treatment of prostate cancer, uterine fibroids and other tissue abnormalities. In principle, HIFU beams can be focused within small volumes which results in forming precise lesions within the target volume (e.g. tumor, atherosclerotic plaque) while sparing the intervening tissue. With this precision, HIFU offers the promise of noninvasive tumor therapy. The goal of this thesis is to develop an image-guidance mode with an interactive image-based computational modeling of tissue response to HIFU. This model could be used in treatment planning and post-treatment retrospective evaluation of treatment outcome(s).
ISBN: 9781321080155Subjects--Topical Terms:
649834
Electrical engineering.
Optimization of Focused Ultrasound and Image Based Modeling in Image Guided Interventions.
LDR
:04619nmm a2200361 4500
001
2059957
005
20150822105424.5
008
170521s2014 ||||||||||||||||| ||eng d
020
$a
9781321080155
035
$a
(MiAaPQ)AAI3630208
035
$a
AAI3630208
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Almekkawy, Mohamed Khaled Ibrahim.
$3
3174090
245
1 0
$a
Optimization of Focused Ultrasound and Image Based Modeling in Image Guided Interventions.
300
$a
141 p.
500
$a
Source: Dissertation Abstracts International, Volume: 75-11(E), Section: B.
500
$a
Adviser: Emad S. Ebbini.
502
$a
Thesis (Ph.D.)--University of Minnesota, 2014.
506
$a
This item must not be sold to any third party vendors.
506
$a
This item must not be added to any third party search indexes.
520
$a
Image-guided high intensity focused ultrasound (HIFU) is becoming increasingly accepted as a form of noninvasive ablative therapy for the treatment of prostate cancer, uterine fibroids and other tissue abnormalities. In principle, HIFU beams can be focused within small volumes which results in forming precise lesions within the target volume (e.g. tumor, atherosclerotic plaque) while sparing the intervening tissue. With this precision, HIFU offers the promise of noninvasive tumor therapy. The goal of this thesis is to develop an image-guidance mode with an interactive image-based computational modeling of tissue response to HIFU. This model could be used in treatment planning and post-treatment retrospective evaluation of treatment outcome(s).
520
$a
Within the context of treatment planning, the challenge of using HIFU to target tumors in organs partially obscured by the rib cage are addressed. Ribs distort HIFU beams in a manner that reduces the focusing gain at the target (tumor) and could cause a treatment-limiting collateral damage. We present a refocusing algorithms to efficiently steer higher power towards the target while limiting power deposition on the ribs, improving the safety and efficacy of tumor ablation. Our approach is based on an approximation of a non-convex to a convex optimization known as the semidefinite relaxation (SDR) technique. An important advantage of the SDR method over previously proposed optimization methods is the explicit control of the sidelobes in the focal plane. A finite-difference time domain (FDTD) heterogeneous propagation model of a 1-MHz concave phased array was used to model the acoustic propagation and temperature simulations in different tissues including ribs.
520
$a
The numerical methods developed for the refocusing problem are also used for retrospective analysis of targeting of atherosclerotic plaques using HIFU. Cases were simulated where seven adjacent HIFU shots (5000 W/cm2, 2 sec exposure time) were focused at the plaque tissue within the posterior wall of external femoral artery. After segmentation of the ultrasound image obtained for the treatment region in-vivo, we integrated this anatomical information into our simulation to account for different parameters that may be caused by these multi-region anatomical complexities. An FDTD heterogeneous model was used for both acoustic field and temperature computations. The acoustic field simulation considered a concave (40-mm radius of curvature) 32-element array operating at 3.5 MHz. To account for the blood flow in the vicinity of the target (plaque), we have used a modified transient bioheat transfer equation (tBHTE) with a convective term. The results from the numerical simulation were in good agreement with the thermal lesions identified by histological examination of the treated tissues.
520
$a
Within the context of accounting for the blood flow in tBHTE, the estimation of the displacement of tissue and blood motion are addressed. A new multi-dimensional speckle tracking method (MDST) utilizing the Riesz transform with subsample accuracy in all dimensions is described. Field II simulation of flow data in a channel is generated to provide a validation of the accuracy of the method. In addition, the new MDST method is applied to imaging data from the carotid artery of a healthy human volunteers. The results obtained show that using Riesz transform produces more robust estimation of the true displacement compared to previously published results.
590
$a
School code: 0130.
650
4
$a
Electrical engineering.
$3
649834
650
4
$a
Biomedical engineering.
$3
535387
650
4
$a
Medical imaging.
$3
3172799
650
4
$a
Acoustics.
$3
879105
690
$a
0544
690
$a
0541
690
$a
0574
690
$a
0986
710
2
$a
University of Minnesota.
$b
Electrical/Computer Engineering.
$3
1672573
773
0
$t
Dissertation Abstracts International
$g
75-11B(E).
790
$a
0130
791
$a
Ph.D.
792
$a
2014
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3630208
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9292615
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入