The impact of hybrid energy storage ...
~
Kelley, Jay Paul.
FindBook
Google Book
Amazon
博客來
The impact of hybrid energy storage on power quality, when high power pulsed DC loads are operated on a microgrid testbed.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
The impact of hybrid energy storage on power quality, when high power pulsed DC loads are operated on a microgrid testbed./
作者:
Kelley, Jay Paul.
面頁冊數:
99 p.
附註:
Source: Masters Abstracts International, Volume: 53-02.
Contained By:
Masters Abstracts International53-02(E).
標題:
Alternative Energy. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1558424
ISBN:
9781303980589
The impact of hybrid energy storage on power quality, when high power pulsed DC loads are operated on a microgrid testbed.
Kelley, Jay Paul.
The impact of hybrid energy storage on power quality, when high power pulsed DC loads are operated on a microgrid testbed.
- 99 p.
Source: Masters Abstracts International, Volume: 53-02.
Thesis (M.S.E.E.)--The University of Texas at Arlington, 2014.
This item must not be sold to any third party vendors.
As the Navy's demands for high power transient loads evolves, so too does the need for alternative energy sources to back-up the more traditional power generation. Such applications in need of support include electrical grid backup and directed energy weapon systems such as electromagnetic launchers, laser systems, and high power microwave generators, among others. Among the alternative generation sources receiving considerable attention are energy storage devices such as rechargeable electrochemical batteries and capacitors. In such applications as those mentioned above, these energy storage devices offer the ability to serve a dual role as both a power source to the various loads as well high power loads themselves to the continual generation when the high power transient loads are in periods of downtime. With the recent developments in electrochemical energy storage, lithium-ion batteries (LIBs) seem like the obvious choice, but previous research has shown that the elevated rates of charging can be detrimental to both the cycle life and the operational life span of the device. In order to preserve the batteries, their charge rate must be limited. One proposed method to accomplish the dual role task mentioned above, while preserving the life of the batteries, is by combining high energy density LIBs with high power density electric double layer capacitors (EDLCs) or lithium-ion capacitors (LICs) using controllable power electronics to adjust the flow of power to and from each device. Such a configuration is typically referred to as hybrid energy storage module (HESM). While shipboard generators start up, the combined high energy density and high power density of the HESM provides the capability to source critical loads for an extended period of time at the high rates they demand. Once the generator is operationally efficient, the HESM can act as a high energy reservoir to harvest the energy from the generator while the loads are in short periods of inactivity. This enables the generator to maintain its operation at levels of high efficiency thereby increasing the power quality of the AC bus. The work discussed here is aimed at evaluating how the use of energy storage impacts the power quality on MicroGrid's AC bus when high rate DC and AC loads are sourced simultaneously. Also HESM has been developed and evaluated as a mean to optimizing both the power and energy density of the energy storage installed.
ISBN: 9781303980589Subjects--Topical Terms:
1035473
Alternative Energy.
The impact of hybrid energy storage on power quality, when high power pulsed DC loads are operated on a microgrid testbed.
LDR
:03449nmm a2200301 4500
001
2056785
005
20150608133911.5
008
170521s2014 ||||||||||||||||| ||eng d
020
$a
9781303980589
035
$a
(MiAaPQ)AAI1558424
035
$a
AAI1558424
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Kelley, Jay Paul.
$3
3170566
245
1 4
$a
The impact of hybrid energy storage on power quality, when high power pulsed DC loads are operated on a microgrid testbed.
300
$a
99 p.
500
$a
Source: Masters Abstracts International, Volume: 53-02.
500
$a
Adviser: David A. Wetz.
502
$a
Thesis (M.S.E.E.)--The University of Texas at Arlington, 2014.
506
$a
This item must not be sold to any third party vendors.
520
$a
As the Navy's demands for high power transient loads evolves, so too does the need for alternative energy sources to back-up the more traditional power generation. Such applications in need of support include electrical grid backup and directed energy weapon systems such as electromagnetic launchers, laser systems, and high power microwave generators, among others. Among the alternative generation sources receiving considerable attention are energy storage devices such as rechargeable electrochemical batteries and capacitors. In such applications as those mentioned above, these energy storage devices offer the ability to serve a dual role as both a power source to the various loads as well high power loads themselves to the continual generation when the high power transient loads are in periods of downtime. With the recent developments in electrochemical energy storage, lithium-ion batteries (LIBs) seem like the obvious choice, but previous research has shown that the elevated rates of charging can be detrimental to both the cycle life and the operational life span of the device. In order to preserve the batteries, their charge rate must be limited. One proposed method to accomplish the dual role task mentioned above, while preserving the life of the batteries, is by combining high energy density LIBs with high power density electric double layer capacitors (EDLCs) or lithium-ion capacitors (LICs) using controllable power electronics to adjust the flow of power to and from each device. Such a configuration is typically referred to as hybrid energy storage module (HESM). While shipboard generators start up, the combined high energy density and high power density of the HESM provides the capability to source critical loads for an extended period of time at the high rates they demand. Once the generator is operationally efficient, the HESM can act as a high energy reservoir to harvest the energy from the generator while the loads are in short periods of inactivity. This enables the generator to maintain its operation at levels of high efficiency thereby increasing the power quality of the AC bus. The work discussed here is aimed at evaluating how the use of energy storage impacts the power quality on MicroGrid's AC bus when high rate DC and AC loads are sourced simultaneously. Also HESM has been developed and evaluated as a mean to optimizing both the power and energy density of the energy storage installed.
590
$a
School code: 2502.
650
4
$a
Alternative Energy.
$3
1035473
650
4
$a
Energy.
$3
876794
650
4
$a
Engineering, Electronics and Electrical.
$3
626636
690
$a
0544
690
$a
0363
690
$a
0791
710
2
$a
The University of Texas at Arlington.
$b
Electrical Engineering.
$3
1018571
773
0
$t
Masters Abstracts International
$g
53-02(E).
790
$a
2502
791
$a
M.S.E.E.
792
$a
2014
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1558424
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9289289
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入