Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Effect of size on ground-coupled hea...
~
Alalaimi, Mohammad Ali.
Linked to FindBook
Google Book
Amazon
博客來
Effect of size on ground-coupled heat pump performance.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Effect of size on ground-coupled heat pump performance./
Author:
Alalaimi, Mohammad Ali.
Description:
33 p.
Notes:
Source: Masters Abstracts International, Volume: 52-04.
Contained By:
Masters Abstracts International52-04(E).
Subject:
Engineering, Mechanical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1550319
ISBN:
9781303651113
Effect of size on ground-coupled heat pump performance.
Alalaimi, Mohammad Ali.
Effect of size on ground-coupled heat pump performance.
- 33 p.
Source: Masters Abstracts International, Volume: 52-04.
Thesis (M.S.)--Duke University, 2013.
Here we document and explain a general trend in the performance of refrigeration and heat pump systems: larger installations are more efficient. We show analytically why the performance of the system must increase with the size of the installation. The second law efficiency of refrigeration systems must increase with their size. We also show that the power requirement a ground-coupled heat pump system must decrease as the size of the ground heat exchanger increases. From these two trends emerges the trade off between the size of the heat pump and the size of the ground heat exchanger. The challenge is to find the optimum size of the ground-coupled heat pump. We show numerically the optimum heat pump size and the ground heat exchanger size that correspond to minimum total power requirement subject to a cost constraint.
ISBN: 9781303651113Subjects--Topical Terms:
783786
Engineering, Mechanical.
Effect of size on ground-coupled heat pump performance.
LDR
:01658nam a2200277 4500
001
1966172
005
20141106122627.5
008
150210s2013 ||||||||||||||||| ||eng d
020
$a
9781303651113
035
$a
(MiAaPQ)AAI1550319
035
$a
AAI1550319
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Alalaimi, Mohammad Ali.
$3
2102971
245
1 0
$a
Effect of size on ground-coupled heat pump performance.
300
$a
33 p.
500
$a
Source: Masters Abstracts International, Volume: 52-04.
500
$a
Advisers: Adrian Bejan; Sylvie Lorente.
502
$a
Thesis (M.S.)--Duke University, 2013.
520
$a
Here we document and explain a general trend in the performance of refrigeration and heat pump systems: larger installations are more efficient. We show analytically why the performance of the system must increase with the size of the installation. The second law efficiency of refrigeration systems must increase with their size. We also show that the power requirement a ground-coupled heat pump system must decrease as the size of the ground heat exchanger increases. From these two trends emerges the trade off between the size of the heat pump and the size of the ground heat exchanger. The challenge is to find the optimum size of the ground-coupled heat pump. We show numerically the optimum heat pump size and the ground heat exchanger size that correspond to minimum total power requirement subject to a cost constraint.
590
$a
School code: 0066.
650
4
$a
Engineering, Mechanical.
$3
783786
650
4
$a
Alternative Energy.
$3
1035473
690
$a
0548
690
$a
0363
710
2
$a
Duke University.
$b
Mechanical Engineering and Materials Science.
$3
1030656
773
0
$t
Masters Abstracts International
$g
52-04(E).
790
$a
0066
791
$a
M.S.
792
$a
2013
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1550319
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9261177
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login