Design and Characterization of Next-Generation Tissue Equivalent Proportional Counters for use in Low Energy Neutron Fields.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Design and Characterization of Next-Generation Tissue Equivalent Proportional Counters for use in Low Energy Neutron Fields./
作者:
Ali, Fawaz.
面頁冊數:
470 p.
附註:
Source: Dissertation Abstracts International, Volume: 75-07(E), Section: B.
Contained By:
Dissertation Abstracts International75-07B(E).
標題:
Engineering, Nuclear. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NS24149
ISBN:
9780499241498
Design and Characterization of Next-Generation Tissue Equivalent Proportional Counters for use in Low Energy Neutron Fields.
Ali, Fawaz.
Design and Characterization of Next-Generation Tissue Equivalent Proportional Counters for use in Low Energy Neutron Fields.
- 470 p.
Source: Dissertation Abstracts International, Volume: 75-07(E), Section: B.
Thesis (Ph.D.)--University of Ontario Institute of Technology (Canada), 2014.
Tissue Equivalent Proportional Counters (TEPCs) are devices that can measure the radiation dose levels for the mixed neutron and gamma ray fields that are encountered in nuclear facilities. TEPC designs typically consist of a low density gas sensitive volume surrounded by a solid wall, each of which is composed of tissue-equivalent material. The response of a TEPC in a radiation field is characterized by two quantities: the sensitivity, defined as the ratio of the counts recorded to the measured dose equivalent, and the dose equivalent energy response, defined as the ratio of the measured dose equivalent to the ambient dose equivalent for the radiation field of a given energy. TEPC technology has great potential for use in low energy neutron fields, such as those in nuclear power plants, however, what hinders its use as a portable area monitor in such fields is its large physical size.
ISBN: 9780499241498Subjects--Topical Terms:
1043651
Engineering, Nuclear.
Design and Characterization of Next-Generation Tissue Equivalent Proportional Counters for use in Low Energy Neutron Fields.
LDR
:03402nam a2200265 4500
001
1963397
005
20140929140213.5
008
150210s2014 ||||||||||||||||| ||eng d
020
$a
9780499241498
035
$a
(MiAaPQ)AAINS24149
035
$a
AAINS24149
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Ali, Fawaz.
$3
2099639
245
1 0
$a
Design and Characterization of Next-Generation Tissue Equivalent Proportional Counters for use in Low Energy Neutron Fields.
300
$a
470 p.
500
$a
Source: Dissertation Abstracts International, Volume: 75-07(E), Section: B.
502
$a
Thesis (Ph.D.)--University of Ontario Institute of Technology (Canada), 2014.
520
$a
Tissue Equivalent Proportional Counters (TEPCs) are devices that can measure the radiation dose levels for the mixed neutron and gamma ray fields that are encountered in nuclear facilities. TEPC designs typically consist of a low density gas sensitive volume surrounded by a solid wall, each of which is composed of tissue-equivalent material. The response of a TEPC in a radiation field is characterized by two quantities: the sensitivity, defined as the ratio of the counts recorded to the measured dose equivalent, and the dose equivalent energy response, defined as the ratio of the measured dose equivalent to the ambient dose equivalent for the radiation field of a given energy. TEPC technology has great potential for use in low energy neutron fields, such as those in nuclear power plants, however, what hinders its use as a portable area monitor in such fields is its large physical size.
520
$a
For any given neutron field, an optimized TEPC design is one that can provide the same or better sensitivity and dose equivalent energy response relative to that offered by a standard spherical TEPC design of five inch diameter albeit with a much smaller physical size to allow for portability. Two optimized TEPC instruments have been designed: the Compact Multi-Element Tissue Equivalent Proportional Counter (CMETEPC), consisting of 113 cylindrical gas sensitive volumes, and the one-quarter inch TEPC-based system (QITEPC), consisting of 392 spherical TEPCs. These instruments are approximately 90% smaller than the standard counter design. To verify that these optimized counters offer the same or better sensitivity and dose equivalent energy response relative to the standard design for realistic nuclear power plant neutron fields, the performance of these instruments when irradiated by the 252Cf -- D2O moderated, 252Cf, and 241Am-Be neutron energy spectra were simulated using the Particle and Heavy Ion Transport Code System (PHITS) three-dimensional radiation transport code. For these fields, it is found that the two instruments do offer the same or better sensitivity and dose equivalent response than the standard counter design. The process of designing the optimized instruments as well as the directional dependence of these instruments' sensitivity and dose equivalent energy response for each of the three abovementioned neutron fields will be presented. This ii thesis presents two novel compact designs for TEPCs that may be suitable for use in area monitoring applications.
590
$a
School code: 1555.
650
4
$a
Engineering, Nuclear.
$3
1043651
690
$a
0552
710
2
$a
University of Ontario Institute of Technology (Canada).
$3
1057491
773
0
$t
Dissertation Abstracts International
$g
75-07B(E).
790
$a
1555
791
$a
Ph.D.
792
$a
2014
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NS24149
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9258395
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入