語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Cadaveric Simulation of Flatfoot and...
~
Roush, Grant C.
FindBook
Google Book
Amazon
博客來
Cadaveric Simulation of Flatfoot and Surgical Corrective Techniques: The Evans versus the Z-osteotomy.
紀錄類型:
書目-語言資料,印刷品 : Monograph/item
正題名/作者:
Cadaveric Simulation of Flatfoot and Surgical Corrective Techniques: The Evans versus the Z-osteotomy./
作者:
Roush, Grant C.
面頁冊數:
54 p.
附註:
Source: Masters Abstracts International, Volume: 51-06.
Contained By:
Masters Abstracts International51-06(E).
標題:
Biophysics, Biomechanics. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1538395
ISBN:
9781303114168
Cadaveric Simulation of Flatfoot and Surgical Corrective Techniques: The Evans versus the Z-osteotomy.
Roush, Grant C.
Cadaveric Simulation of Flatfoot and Surgical Corrective Techniques: The Evans versus the Z-osteotomy.
- 54 p.
Source: Masters Abstracts International, Volume: 51-06.
Thesis (Master's)--University of Washington, 2013.
The main clinical purpose of this study is to compare two different surgical procedures, the Evans calcaneal osteotomy and the Z-osteotomy, both of which are used to correct Stage II (flexible) cases of flatfoot deformity. This work is a follow-up to a pilot study completed previously by the VA Center of Excellence for Limb Loss Prevention and Prosthetic Engineering (VA RR&D). In that study, the feet (both flat and corrected) were statically placed at mid-stance of the gait cycle and data were collected. Kinematic and kinetic comparisons were made to see how each surgery performed in restoring the foot to normal shape and function. This research looks to build on that study by using a fully dynamic in vitro simulation of the stance phase of gait.
ISBN: 9781303114168Subjects--Topical Terms:
1035342
Biophysics, Biomechanics.
Cadaveric Simulation of Flatfoot and Surgical Corrective Techniques: The Evans versus the Z-osteotomy.
LDR
:03878nam 2200325 4500
001
1958035
005
20140224122704.5
008
150212s2013 ||||||||||||||||| ||eng d
020
$a
9781303114168
035
$a
(MiAaPQ)AAI1538395
035
$a
AAI1538395
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Roush, Grant C.
$3
2092995
245
1 0
$a
Cadaveric Simulation of Flatfoot and Surgical Corrective Techniques: The Evans versus the Z-osteotomy.
300
$a
54 p.
500
$a
Source: Masters Abstracts International, Volume: 51-06.
500
$a
Adviser: William R. Ledoux.
502
$a
Thesis (Master's)--University of Washington, 2013.
520
$a
The main clinical purpose of this study is to compare two different surgical procedures, the Evans calcaneal osteotomy and the Z-osteotomy, both of which are used to correct Stage II (flexible) cases of flatfoot deformity. This work is a follow-up to a pilot study completed previously by the VA Center of Excellence for Limb Loss Prevention and Prosthetic Engineering (VA RR&D). In that study, the feet (both flat and corrected) were statically placed at mid-stance of the gait cycle and data were collected. Kinematic and kinetic comparisons were made to see how each surgery performed in restoring the foot to normal shape and function. This research looks to build on that study by using a fully dynamic in vitro simulation of the stance phase of gait.
520
$a
A process of ligament attenuation coupled with axial loading of the foot has been developed by our group to induce a flexible flatfoot on neutrally aligned cadaveric specimens. Previous research has shown the ligaments most involved in supporting the medial arch were the superomedial and inferomedial calcaneonavicular (spring), talocalcaneal interosseous, plantar naviculocuneiform, plantar first metatarsocuneiform, and anterior superficial deltoid ligaments. To induce weakening in our study, these ligaments were either sectioned or attenuated with multiple longitudinal incisions parallel to the fiber orientation, after which the foot was cyclically loaded from 10 N to body weight at 2 Hz until visual evidence of flatfoot was seen. In addition, X-rays were taken and clinical measurements were performed to assess foot shape initially, after the flattening procedure, and post-surgery. The repeatability of making these measures was also investigated.
520
$a
Gait simulation was performed with the robotic gait simulator (RGS) at the VA RR&D. The RGS was developed to allow for in vitro simulation of the stance phase of gait using cadaveric specimens. It has been shown to accurately simulate both the kinematics and kinetics of the foot during the stance phase of gait. Having a physiologically correct model will allow for the most accurate representation of in vivo gait currently possible, while also allowing the utilization of invasive measurement techniques (such as insertion of bone pins) or multiple surgical procedures that would otherwise be impossible on living human subjects.
520
$a
Results from this work have shown that our flatfoot model has the ability to create a mild Stage II flatfoot deformity in previously neutrally aligned cadaveric specimens. Additionally, evidence proved our process for collecting and measuring clinically relevant radiographic measures was highly repeatable. Both static radiographic evidence and dynamic simulation showed significant differences after lateral column lengthening, most notably an increase in lateral peak plantar pressures post-surgery, but there were few differences when comparing the two surgical procedures.
590
$a
School code: 0250.
650
4
$a
Biophysics, Biomechanics.
$3
1035342
650
4
$a
Engineering, Mechanical.
$3
783786
650
4
$a
Engineering, General.
$3
1020744
690
$a
0648
690
$a
0548
690
$a
0537
710
2
$a
University of Washington.
$b
Mechanical Engineering.
$3
2092993
773
0
$t
Masters Abstracts International
$g
51-06(E).
790
$a
0250
791
$a
Master's
792
$a
2013
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1538395
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9252863
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入