Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Power system online stability assess...
~
Zheng, Ce.
Linked to FindBook
Google Book
Amazon
博客來
Power system online stability assessment using synchrophasor data mining.
Record Type:
Language materials, printed : Monograph/item
Title/Author:
Power system online stability assessment using synchrophasor data mining./
Author:
Zheng, Ce.
Description:
167 p.
Notes:
Source: Dissertation Abstracts International, Volume: 74-11(E), Section: B.
Contained By:
Dissertation Abstracts International74-11B(E).
Subject:
Engineering, Electronics and Electrical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3572256
ISBN:
9781303305108
Power system online stability assessment using synchrophasor data mining.
Zheng, Ce.
Power system online stability assessment using synchrophasor data mining.
- 167 p.
Source: Dissertation Abstracts International, Volume: 74-11(E), Section: B.
Thesis (Ph.D.)--Texas A&M University, 2013.
Traditional power system stability assessment based on full model computation shows its drawbacks in real-time applications where fast variations are present at both demand side and supply side.
ISBN: 9781303305108Subjects--Topical Terms:
626636
Engineering, Electronics and Electrical.
Power system online stability assessment using synchrophasor data mining.
LDR
:03484nam a2200337 4500
001
1957232
005
20141222143824.5
008
150210s2013 ||||||||||||||||| ||eng d
020
$a
9781303305108
035
$a
(MiAaPQ)AAI3572256
035
$a
AAI3572256
040
$a
MiAaPQ
$c
MiAaPQ
100
1
$a
Zheng, Ce.
$3
2092088
245
1 0
$a
Power system online stability assessment using synchrophasor data mining.
300
$a
167 p.
500
$a
Source: Dissertation Abstracts International, Volume: 74-11(E), Section: B.
500
$a
Adviser: Electrical and Computer Engineering.
502
$a
Thesis (Ph.D.)--Texas A&M University, 2013.
520
$a
Traditional power system stability assessment based on full model computation shows its drawbacks in real-time applications where fast variations are present at both demand side and supply side.
520
$a
This work presents the use of data mining techniques, in particular the Decision Trees (DTs), for fast evaluation of power system oscillatory stability and voltage stability from synchrophasor measurements. A regression tree-based approach is proposed to predict the stability margins. Modal analysis and continuation power flow are the tools used to build the knowledge base for off-line DT training. Corresponding metrics include the damping ratio of critical electromechanical oscillation mode and MW-distance to the voltage instability region. Classification trees are used to group an operating point into predefined stability state based on the value of corresponding stability indicator. A novel methodology for knowledge base creation has been elaborated to assure practical and sufficient training data. Encouraging results are obtained through performance examination.
520
$a
The robustness of the proposed predictor to measurement errors and system topological variations is analyzed. A scheme has been proposed to tackle the problem of when and how to update the data mining tool for seamless online stability monitoring. The optimal placement for the phasor measurement units (PMU) based on the importance of DT variables is suggested.
520
$a
A measurement-based voltage stability index is proposed and evaluated using field PMU measurements. It is later revised to evaluate the impact of wind generation on distribution system voltage stability.
520
$a
Next, a new data mining tool, the Probabilistic Collocation Method (PCM), is presented as a computationally efficient method to conduct the uncertainty analysis. As compared with the traditional Monte Carlo simulation method, the collocation method could provide a quite accurate approximation with fewer simulation runs.
520
$a
Finally, we show how to overcome the disadvantages of mode meters and ringdown analyzers by using DTs to directly map synchrophasor measurements to predefined oscillatory stability states. The proposed measurement-based approach is examined using synthetic data from simulations on IEEE test systems, and PMU measurements collected from field substations. Results indicate that the proposed method complements the traditional model-based approach, enhancing situational awareness of control center operators in real time stability monitoring and control.
590
$a
School code: 0803.
650
4
$a
Engineering, Electronics and Electrical.
$3
626636
650
4
$a
Engineering, Computer.
$3
1669061
690
$a
0544
690
$a
0464
710
2
$a
Texas A&M University.
$b
Electrical and Computer Engineering.
$3
2092089
773
0
$t
Dissertation Abstracts International
$g
74-11B(E).
790
$a
0803
791
$a
Ph.D.
792
$a
2013
793
$a
English
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3572256
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9252063
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login