Tactile imaging.
~
Wellman, Parris Saxon.
FindBook
Google Book
Amazon
博客來
Tactile imaging.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Tactile imaging./
作者:
Wellman, Parris Saxon.
面頁冊數:
137 p.
附註:
Source: Dissertation Abstracts International, Volume: 60-06, Section: B, page: 2808.
Contained By:
Dissertation Abstracts International60-06B.
標題:
Engineering, Biomedical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9935928
ISBN:
0599371129
Tactile imaging.
Wellman, Parris Saxon.
Tactile imaging.
- 137 p.
Source: Dissertation Abstracts International, Volume: 60-06, Section: B, page: 2808.
Thesis (Ph.D.)--Harvard University, 1999.
Palpation is a ubiquitous skill that we use every day, from finding a button-hole in a shirt to determining if fruit is ripe in the grocery store. Nowhere is it more important than when it is used by physicians in the discovery and assessment of disease. The problem with this technique is that it can be difficult to accurately verbalize and record tactile sensations, which makes the comparison of two manual examinations extremely difficult. This thesis presents a new medical imaging technique, tactile imaging, which promises to alleviate this difficulty through more objective documentation of clinical examinations. We present one implementation of such a system, targeted at the documentation of the properties of palpable breast lumps. It is comprised of a hand held scan head with a distributed pressure sensor mounted on it and a magnetic position tracker contained within it that is stroked across the surface of the breast by a clinician. The pressure distribution on the face of the sensor and its location in space are recorded using a computer and an algorithm assembles a composite tactile map of the structure in real time. This map is the average of all pressures recorded at a particular location in the breast as the physician examines it. In order to extract features from these maps, we have developed mathematical models that relate material and geometric properties of palpable lumps to surface pressure distributions. These models were used to develop inversion algorithms that can be used to extract the size of the lumps imaged. In clinical tests on 25 surgical patients, size estimate accuracy (compared to ex vivo size measurements) was within 13% mean absolute error (MAE). This compares favorably to 34% and 47%, MAE, respectively, for ultrasound estimates and clinical breast examination estimates. Across multiple maps, size repeatability was within 7.5% (one standard deviation). Tactile imaging therefore promises to improve the objectivity of clinical breast examination.
ISBN: 0599371129Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Tactile imaging.
LDR
:02825nmm 2200277 4500
001
1861165
005
20041111103132.5
008
130614s1999 eng d
020
$a
0599371129
035
$a
(UnM)AAI9935928
035
$a
AAI9935928
040
$a
UnM
$c
UnM
100
1
$a
Wellman, Parris Saxon.
$3
1948777
245
1 0
$a
Tactile imaging.
300
$a
137 p.
500
$a
Source: Dissertation Abstracts International, Volume: 60-06, Section: B, page: 2808.
500
$a
Chair: Robert D. Howe.
502
$a
Thesis (Ph.D.)--Harvard University, 1999.
520
$a
Palpation is a ubiquitous skill that we use every day, from finding a button-hole in a shirt to determining if fruit is ripe in the grocery store. Nowhere is it more important than when it is used by physicians in the discovery and assessment of disease. The problem with this technique is that it can be difficult to accurately verbalize and record tactile sensations, which makes the comparison of two manual examinations extremely difficult. This thesis presents a new medical imaging technique, tactile imaging, which promises to alleviate this difficulty through more objective documentation of clinical examinations. We present one implementation of such a system, targeted at the documentation of the properties of palpable breast lumps. It is comprised of a hand held scan head with a distributed pressure sensor mounted on it and a magnetic position tracker contained within it that is stroked across the surface of the breast by a clinician. The pressure distribution on the face of the sensor and its location in space are recorded using a computer and an algorithm assembles a composite tactile map of the structure in real time. This map is the average of all pressures recorded at a particular location in the breast as the physician examines it. In order to extract features from these maps, we have developed mathematical models that relate material and geometric properties of palpable lumps to surface pressure distributions. These models were used to develop inversion algorithms that can be used to extract the size of the lumps imaged. In clinical tests on 25 surgical patients, size estimate accuracy (compared to ex vivo size measurements) was within 13% mean absolute error (MAE). This compares favorably to 34% and 47%, MAE, respectively, for ultrasound estimates and clinical breast examination estimates. Across multiple maps, size repeatability was within 7.5% (one standard deviation). Tactile imaging therefore promises to improve the objectivity of clinical breast examination.
590
$a
School code: 0084.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Health Sciences, Radiology.
$3
1019076
690
$a
0541
690
$a
0574
710
2 0
$a
Harvard University.
$3
528741
773
0
$t
Dissertation Abstracts International
$g
60-06B.
790
1 0
$a
Howe, Robert D.,
$e
advisor
790
$a
0084
791
$a
Ph.D.
792
$a
1999
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9935928
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9179865
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入