語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Technologies for assessment of perso...
~
Singh, Manisha.
FindBook
Google Book
Amazon
博客來
Technologies for assessment of personal (population) exposure to toxic components of airborne particulate matter.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Technologies for assessment of personal (population) exposure to toxic components of airborne particulate matter./
作者:
Singh, Manisha.
面頁冊數:
214 p.
附註:
Source: Dissertation Abstracts International, Volume: 65-09, Section: B, page: 4762.
Contained By:
Dissertation Abstracts International65-09B.
標題:
Engineering, Environmental. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3145287
ISBN:
0496048856
Technologies for assessment of personal (population) exposure to toxic components of airborne particulate matter.
Singh, Manisha.
Technologies for assessment of personal (population) exposure to toxic components of airborne particulate matter.
- 214 p.
Source: Dissertation Abstracts International, Volume: 65-09, Section: B, page: 4762.
Thesis (Ph.D.)--University of Southern California, 2004.
There is increasing awareness that the airborne particulate matter (PM) concentrations measured by ambient fixed-point monitors may not accurately reflect the true exposure levels of a population. This thesis is intended to alleviate the paucity of information on individual (population) exposures to different size fractions including the ultrafine fraction of PM. A personal sampler for PM that, for the first time, allows for the separation of airborne particles by size, and simultaneous analyses of the particles for toxic content has been developed. The Personal Cascade Impactor Sampler (PCIS) developed in this research is a miniaturized cascade impactor, consisting of four impaction stages, followed by an after-filter. Particles are separated in the following aerodynamic particle diameter ranges: <0.25, 0.25--0.5, 0.5--1.0, 1.0--2.5 and 2.5--10 mum. The PCIS operates at a flow rate of 9 LPM using a very high efficiency, battery-operated light pump at a pressure drop of only 11 in H2O (2.7 kPa). PCIS was first characterized in the laboratory using PTFE (Teflon), quartz and aluminum substrates. Laboratory tests corroborated the cutpoints. Particle loading tests indicated that the PCIS stages could collect up to 3.16 and 0.7 mg of fine and coarse PM, respectively, without any loss in the collection efficiency. Two field studies were conducted to evaluate PCIS's performance for sampling real-life particulates. Coarse PM mass, time-integrated (size fractionated) PM 2.5 mass, inorganic ions (nitrate and sulfate), elemental carbon and organic carbon as well as near-continuous total carbon and nitrate concentration measurements by PCIS were evaluated by comparisons to collocated samplers in the first field evaluation. The sampling efficiency of PCIS was also evaluated in wind tunnel tests, which confirmed that sampling and collection of super-micrometer particles by the PCIS is unaffected at wind speeds as high as 8 km/h. The second field study evaluated PCIS measurements of PM mass and PM trace metals by ICP-MS. A total of 10 PM-bound trace metals e.g. Ti, V, Mn, Cu, Sr, Cd, Sb, Ba, Ce and Pb were quantified by ICP-MS technique. Probable sources of these metals have been identified based on the mass size distributions. The final chapter of this research is dedicated to investigation of a toxic component of the PM---particle bound metals in one of the unique air basins of the world---The Los Angeles Basin. A better understanding of these toxic components of PM with respect to spatial, diurnal and seasonal variability will provide background information upon which we could base long-term campaigns for population exposure assessments.
ISBN: 0496048856Subjects--Topical Terms:
783782
Engineering, Environmental.
Technologies for assessment of personal (population) exposure to toxic components of airborne particulate matter.
LDR
:03641nmm 2200289 4500
001
1852068
005
20051229075128.5
008
130614s2004 eng d
020
$a
0496048856
035
$a
(UnM)AAI3145287
035
$a
AAI3145287
040
$a
UnM
$c
UnM
100
1
$a
Singh, Manisha.
$3
1939941
245
1 0
$a
Technologies for assessment of personal (population) exposure to toxic components of airborne particulate matter.
300
$a
214 p.
500
$a
Source: Dissertation Abstracts International, Volume: 65-09, Section: B, page: 4762.
500
$a
Adviser: Constantinos Sioutas.
502
$a
Thesis (Ph.D.)--University of Southern California, 2004.
520
$a
There is increasing awareness that the airborne particulate matter (PM) concentrations measured by ambient fixed-point monitors may not accurately reflect the true exposure levels of a population. This thesis is intended to alleviate the paucity of information on individual (population) exposures to different size fractions including the ultrafine fraction of PM. A personal sampler for PM that, for the first time, allows for the separation of airborne particles by size, and simultaneous analyses of the particles for toxic content has been developed. The Personal Cascade Impactor Sampler (PCIS) developed in this research is a miniaturized cascade impactor, consisting of four impaction stages, followed by an after-filter. Particles are separated in the following aerodynamic particle diameter ranges: <0.25, 0.25--0.5, 0.5--1.0, 1.0--2.5 and 2.5--10 mum. The PCIS operates at a flow rate of 9 LPM using a very high efficiency, battery-operated light pump at a pressure drop of only 11 in H2O (2.7 kPa). PCIS was first characterized in the laboratory using PTFE (Teflon), quartz and aluminum substrates. Laboratory tests corroborated the cutpoints. Particle loading tests indicated that the PCIS stages could collect up to 3.16 and 0.7 mg of fine and coarse PM, respectively, without any loss in the collection efficiency. Two field studies were conducted to evaluate PCIS's performance for sampling real-life particulates. Coarse PM mass, time-integrated (size fractionated) PM 2.5 mass, inorganic ions (nitrate and sulfate), elemental carbon and organic carbon as well as near-continuous total carbon and nitrate concentration measurements by PCIS were evaluated by comparisons to collocated samplers in the first field evaluation. The sampling efficiency of PCIS was also evaluated in wind tunnel tests, which confirmed that sampling and collection of super-micrometer particles by the PCIS is unaffected at wind speeds as high as 8 km/h. The second field study evaluated PCIS measurements of PM mass and PM trace metals by ICP-MS. A total of 10 PM-bound trace metals e.g. Ti, V, Mn, Cu, Sr, Cd, Sb, Ba, Ce and Pb were quantified by ICP-MS technique. Probable sources of these metals have been identified based on the mass size distributions. The final chapter of this research is dedicated to investigation of a toxic component of the PM---particle bound metals in one of the unique air basins of the world---The Los Angeles Basin. A better understanding of these toxic components of PM with respect to spatial, diurnal and seasonal variability will provide background information upon which we could base long-term campaigns for population exposure assessments.
590
$a
School code: 0208.
650
4
$a
Engineering, Environmental.
$3
783782
650
4
$a
Environmental Sciences.
$3
676987
650
4
$a
Health Sciences, Occupational Health and Safety.
$3
1017799
690
$a
0775
690
$a
0768
690
$a
0354
710
2 0
$a
University of Southern California.
$3
700129
773
0
$t
Dissertation Abstracts International
$g
65-09B.
790
1 0
$a
Sioutas, Constantinos,
$e
advisor
790
$a
0208
791
$a
Ph.D.
792
$a
2004
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3145287
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9201582
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入