語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Technical developments for in-vivo a...
~
Kim, Donghyun.
FindBook
Google Book
Amazon
博客來
Technical developments for in-vivo atomic hydrogen magnetic resonance spectroscopic imaging.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Technical developments for in-vivo atomic hydrogen magnetic resonance spectroscopic imaging./
作者:
Kim, Donghyun.
面頁冊數:
104 p.
附註:
Source: Dissertation Abstracts International, Volume: 64-09, Section: B, page: 4526.
Contained By:
Dissertation Abstracts International64-09B.
標題:
Engineering, Electronics and Electrical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3104259
ISBN:
0496518275
Technical developments for in-vivo atomic hydrogen magnetic resonance spectroscopic imaging.
Kim, Donghyun.
Technical developments for in-vivo atomic hydrogen magnetic resonance spectroscopic imaging.
- 104 p.
Source: Dissertation Abstracts International, Volume: 64-09, Section: B, page: 4526.
Thesis (Ph.D.)--Stanford University, 2003.
Magnetic Resonance Spectroscopic Imaging (MRSI) combines the technical features of both imaging and spectroscopy by providing the metabolite information over a spatial distribution. To date, most clinical applications of MRSI have concentrated towards regions of the brain. Recently however, there has been increased attention towards clinical applications beyond the brain. Some of the difficulties associated with MRSI outside of the brain include main field inhomogeneity, efficient spatial coverage schemes, strong lipid signals, and motion related artifacts.
ISBN: 0496518275Subjects--Topical Terms:
626636
Engineering, Electronics and Electrical.
Technical developments for in-vivo atomic hydrogen magnetic resonance spectroscopic imaging.
LDR
:03369nmm 2200325 4500
001
1843963
005
20051017073419.5
008
130614s2003 eng d
020
$a
0496518275
035
$a
(UnM)AAI3104259
035
$a
AAI3104259
040
$a
UnM
$c
UnM
100
1
$a
Kim, Donghyun.
$3
1932173
245
1 0
$a
Technical developments for in-vivo atomic hydrogen magnetic resonance spectroscopic imaging.
300
$a
104 p.
500
$a
Source: Dissertation Abstracts International, Volume: 64-09, Section: B, page: 4526.
500
$a
Adviser: Daniel Spielman.
502
$a
Thesis (Ph.D.)--Stanford University, 2003.
520
$a
Magnetic Resonance Spectroscopic Imaging (MRSI) combines the technical features of both imaging and spectroscopy by providing the metabolite information over a spatial distribution. To date, most clinical applications of MRSI have concentrated towards regions of the brain. Recently however, there has been increased attention towards clinical applications beyond the brain. Some of the difficulties associated with MRSI outside of the brain include main field inhomogeneity, efficient spatial coverage schemes, strong lipid signals, and motion related artifacts.
520
$a
This work describes several technical developments for improving in vivo proton MRSI. The developments are primarily targeted for applications beyond the brain but are also useful for brain studies as well.
520
$a
The first development involves improving main field homogeneity, which plays a crucial role in MRSI. This work presents a method for improving the field homogeneity via a fast field mapping sequence and using a regularization algorithm to correct for field inhomogeneities. The regularization algorithm prevents adverse situations, which can commonly occur when correcting the field for off-centered regions of interest such as in applications outside of the brain. In vivo examples demonstrate the increased homogeneity using the method.
520
$a
The second development relates to designing a pulse sequence optimized for MRSI applications beyond the brain. Spectral-spatial excitation pulses and very selective saturation pulses are used for suppression of lipids and/or any other unwanted signals. Spiral based readout gradients are used for efficient full volumetric coverage. In addition, a method for designing variable density spiral trajectories using analytic solutions is given. Using variable density spirals, lipid ringing can be reduced by improving the spatial impulse response of the signal.
520
$a
The third development involves a method for motion correction in MRSI. Using the characteristics of spiral based readout trajectories, data can be post-processed to correct for motion-induced artifacts similar to techniques used in single voxel spectroscopic studies. Phantom and in vivo examples from regions of the body susceptible to motion show that the signal-to-noise ratio (SNR) of the metabolites can be improved using this correction scheme. Finally, a spiral based readout trajectory that is insensitive to motion is introduced.
590
$a
School code: 0212.
650
4
$a
Engineering, Electronics and Electrical.
$3
626636
650
4
$a
Engineering, Biomedical.
$3
1017684
690
$a
0544
690
$a
0541
710
2 0
$a
Stanford University.
$3
754827
773
0
$t
Dissertation Abstracts International
$g
64-09B.
790
1 0
$a
Spielman, Daniel,
$e
advisor
790
$a
0212
791
$a
Ph.D.
792
$a
2003
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3104259
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9193477
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入