Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Microelectroporation technology for ...
~
Huang, Yong.
Linked to FindBook
Google Book
Amazon
博客來
Microelectroporation technology for genetic engineering.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Microelectroporation technology for genetic engineering./
Author:
Huang, Yong.
Description:
183 p.
Notes:
Source: Dissertation Abstracts International, Volume: 62-07, Section: B, page: 3286.
Contained By:
Dissertation Abstracts International62-07B.
Subject:
Engineering, Biomedical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3019681
ISBN:
0493308903
Microelectroporation technology for genetic engineering.
Huang, Yong.
Microelectroporation technology for genetic engineering.
- 183 p.
Source: Dissertation Abstracts International, Volume: 62-07, Section: B, page: 3286.
Thesis (Ph.D.)--University of California, Berkeley, 2001.
Electroporation, in which electrical pulses are applied across biological cells to permeabilize the cell membranes, is widely used in biotechnology to introduce macromolecules, in particular gene constructs, into biological cells. Conventional electroporation is performed on a large population of cells and employs an empirical trial-and-error procedure, which limits its effectiveness. The fundamental nature of electroporation is not well understood. To improve the effectiveness of electroporation and to develop a tool for studying the fundamental biophysics of electroporation, micro-electromechanical (MEMS) technology was used to develop a chip that can incorporate individual cells in the chip circuit and electroporate the cells under controlled conditions. The control of electroporation in individual cells is made possible by the fact that electroporated cells allow flow of ions across the cell membranes and this flow can be measured and used as a feedback. This single cell level electroporation method is referred as to "micro-electroporation".
ISBN: 0493308903Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Microelectroporation technology for genetic engineering.
LDR
:03556nmm 2200325 4500
001
1840744
005
20050822101734.5
008
130614s2001 eng d
020
$a
0493308903
035
$a
(UnM)AAI3019681
035
$a
AAI3019681
040
$a
UnM
$c
UnM
100
1
$a
Huang, Yong.
$3
1257160
245
1 0
$a
Microelectroporation technology for genetic engineering.
300
$a
183 p.
500
$a
Source: Dissertation Abstracts International, Volume: 62-07, Section: B, page: 3286.
500
$a
Chair: Boris Rubinsky.
502
$a
Thesis (Ph.D.)--University of California, Berkeley, 2001.
520
$a
Electroporation, in which electrical pulses are applied across biological cells to permeabilize the cell membranes, is widely used in biotechnology to introduce macromolecules, in particular gene constructs, into biological cells. Conventional electroporation is performed on a large population of cells and employs an empirical trial-and-error procedure, which limits its effectiveness. The fundamental nature of electroporation is not well understood. To improve the effectiveness of electroporation and to develop a tool for studying the fundamental biophysics of electroporation, micro-electromechanical (MEMS) technology was used to develop a chip that can incorporate individual cells in the chip circuit and electroporate the cells under controlled conditions. The control of electroporation in individual cells is made possible by the fact that electroporated cells allow flow of ions across the cell membranes and this flow can be measured and used as a feedback. This single cell level electroporation method is referred as to "micro-electroporation".
520
$a
In this thesis the fundamental principles of microelectroporation are discussed first. Then the microfabrication procedure for the microelectroporation chip is described. The properties of the chip are examined through experiments with different types of cells as well as mathematical analysis. It is demonstrated that the chip can be used to induce reversible electroporation in individual cells under controlled conditions and that the electrical parameters of electroporation can be determined.
520
$a
Subsequently, a membrane impermeant nucleic acid stain (YOYO-1) was used with fluorescence intensity analysis to demonstrate how microelectroporation technology can be used to regulate cross membrane transport of macromolecules by means of adjusting the strength and length of electroporation pulses.
520
$a
The ability of the microelectroporation technology to genetically manipulate individual cells was demonstrated by inserting an EGFP gene construct into a prostate cancer cell that resided in the chip. The engineered cell was incubated in the chip and successfully expressed the gene.
520
$a
Finally, the microelectroporation technology made it possible to discover that there is a significant difference between membrane currents of live and dead cells. This suggested that measuring cell membrane current with the microelectroporation chip could provide an instantaneous electrical means to detect cell viability.
520
$a
In summary, the dissertation introduces microelectroporation technology and demonstrates its potential in biotechnology, particularly genetic engineering.
590
$a
School code: 0028.
650
4
$a
Engineering, Biomedical.
$3
1017684
690
$a
0541
710
2 0
$a
University of California, Berkeley.
$3
687832
773
0
$t
Dissertation Abstracts International
$g
62-07B.
790
1 0
$a
Rubinsky, Boris,
$e
advisor
790
$a
0028
791
$a
Ph.D.
792
$a
2001
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3019681
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9190258
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login