語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Microelectroporation technology for ...
~
Huang, Yong.
FindBook
Google Book
Amazon
博客來
Microelectroporation technology for genetic engineering.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Microelectroporation technology for genetic engineering./
作者:
Huang, Yong.
面頁冊數:
183 p.
附註:
Source: Dissertation Abstracts International, Volume: 62-07, Section: B, page: 3286.
Contained By:
Dissertation Abstracts International62-07B.
標題:
Engineering, Biomedical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3019681
ISBN:
0493308903
Microelectroporation technology for genetic engineering.
Huang, Yong.
Microelectroporation technology for genetic engineering.
- 183 p.
Source: Dissertation Abstracts International, Volume: 62-07, Section: B, page: 3286.
Thesis (Ph.D.)--University of California, Berkeley, 2001.
Electroporation, in which electrical pulses are applied across biological cells to permeabilize the cell membranes, is widely used in biotechnology to introduce macromolecules, in particular gene constructs, into biological cells. Conventional electroporation is performed on a large population of cells and employs an empirical trial-and-error procedure, which limits its effectiveness. The fundamental nature of electroporation is not well understood. To improve the effectiveness of electroporation and to develop a tool for studying the fundamental biophysics of electroporation, micro-electromechanical (MEMS) technology was used to develop a chip that can incorporate individual cells in the chip circuit and electroporate the cells under controlled conditions. The control of electroporation in individual cells is made possible by the fact that electroporated cells allow flow of ions across the cell membranes and this flow can be measured and used as a feedback. This single cell level electroporation method is referred as to "micro-electroporation".
ISBN: 0493308903Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Microelectroporation technology for genetic engineering.
LDR
:03556nmm 2200325 4500
001
1840744
005
20050822101734.5
008
130614s2001 eng d
020
$a
0493308903
035
$a
(UnM)AAI3019681
035
$a
AAI3019681
040
$a
UnM
$c
UnM
100
1
$a
Huang, Yong.
$3
1257160
245
1 0
$a
Microelectroporation technology for genetic engineering.
300
$a
183 p.
500
$a
Source: Dissertation Abstracts International, Volume: 62-07, Section: B, page: 3286.
500
$a
Chair: Boris Rubinsky.
502
$a
Thesis (Ph.D.)--University of California, Berkeley, 2001.
520
$a
Electroporation, in which electrical pulses are applied across biological cells to permeabilize the cell membranes, is widely used in biotechnology to introduce macromolecules, in particular gene constructs, into biological cells. Conventional electroporation is performed on a large population of cells and employs an empirical trial-and-error procedure, which limits its effectiveness. The fundamental nature of electroporation is not well understood. To improve the effectiveness of electroporation and to develop a tool for studying the fundamental biophysics of electroporation, micro-electromechanical (MEMS) technology was used to develop a chip that can incorporate individual cells in the chip circuit and electroporate the cells under controlled conditions. The control of electroporation in individual cells is made possible by the fact that electroporated cells allow flow of ions across the cell membranes and this flow can be measured and used as a feedback. This single cell level electroporation method is referred as to "micro-electroporation".
520
$a
In this thesis the fundamental principles of microelectroporation are discussed first. Then the microfabrication procedure for the microelectroporation chip is described. The properties of the chip are examined through experiments with different types of cells as well as mathematical analysis. It is demonstrated that the chip can be used to induce reversible electroporation in individual cells under controlled conditions and that the electrical parameters of electroporation can be determined.
520
$a
Subsequently, a membrane impermeant nucleic acid stain (YOYO-1) was used with fluorescence intensity analysis to demonstrate how microelectroporation technology can be used to regulate cross membrane transport of macromolecules by means of adjusting the strength and length of electroporation pulses.
520
$a
The ability of the microelectroporation technology to genetically manipulate individual cells was demonstrated by inserting an EGFP gene construct into a prostate cancer cell that resided in the chip. The engineered cell was incubated in the chip and successfully expressed the gene.
520
$a
Finally, the microelectroporation technology made it possible to discover that there is a significant difference between membrane currents of live and dead cells. This suggested that measuring cell membrane current with the microelectroporation chip could provide an instantaneous electrical means to detect cell viability.
520
$a
In summary, the dissertation introduces microelectroporation technology and demonstrates its potential in biotechnology, particularly genetic engineering.
590
$a
School code: 0028.
650
4
$a
Engineering, Biomedical.
$3
1017684
690
$a
0541
710
2 0
$a
University of California, Berkeley.
$3
687832
773
0
$t
Dissertation Abstracts International
$g
62-07B.
790
1 0
$a
Rubinsky, Boris,
$e
advisor
790
$a
0028
791
$a
Ph.D.
792
$a
2001
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3019681
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9190258
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入