Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Small force detection using microcan...
~
Chiaverini, John.
Linked to FindBook
Google Book
Amazon
博客來
Small force detection using microcantilevers: Search for sub-millimeter-range deviation from Newtonian gravity.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Small force detection using microcantilevers: Search for sub-millimeter-range deviation from Newtonian gravity./
Author:
Chiaverini, John.
Description:
154 p.
Notes:
Source: Dissertation Abstracts International, Volume: 64-03, Section: B, page: 1284.
Contained By:
Dissertation Abstracts International64-03B.
Subject:
Physics, General. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3085267
ISBN:
0496330740
Small force detection using microcantilevers: Search for sub-millimeter-range deviation from Newtonian gravity.
Chiaverini, John.
Small force detection using microcantilevers: Search for sub-millimeter-range deviation from Newtonian gravity.
- 154 p.
Source: Dissertation Abstracts International, Volume: 64-03, Section: B, page: 1284.
Thesis (Ph.D.)--Stanford University, 2003.
Newtonian gravity has been tested on length scales from the astronomical to roughly a millimeter, but this lower limit is still quite large compared to the pertinent quantum mechanical length scale of gravitation, the Planck length. All the other forces of nature have been studied at correspondingly small scales, roughly the Compton wavelength of the interacting particles. Recent theoretical work suggests that exploration of the gravitational force below a millimeter may help explain the hierarchy problem (gravity's weakness compared to the other forces) or put tighter constraints on supersymmetric models. It has been suggested that the discovery of non-Newtonian behavior is possible at length scales in the range of a micron to a millimeter.
ISBN: 0496330740Subjects--Topical Terms:
1018488
Physics, General.
Small force detection using microcantilevers: Search for sub-millimeter-range deviation from Newtonian gravity.
LDR
:02803nmm 2200277 4500
001
1838391
005
20050526083749.5
008
130614s2003 eng d
020
$a
0496330740
035
$a
(UnM)AAI3085267
035
$a
AAI3085267
040
$a
UnM
$c
UnM
100
1
$a
Chiaverini, John.
$3
1926809
245
1 0
$a
Small force detection using microcantilevers: Search for sub-millimeter-range deviation from Newtonian gravity.
300
$a
154 p.
500
$a
Source: Dissertation Abstracts International, Volume: 64-03, Section: B, page: 1284.
500
$a
Adviser: Aharon Kapitulnik.
502
$a
Thesis (Ph.D.)--Stanford University, 2003.
520
$a
Newtonian gravity has been tested on length scales from the astronomical to roughly a millimeter, but this lower limit is still quite large compared to the pertinent quantum mechanical length scale of gravitation, the Planck length. All the other forces of nature have been studied at correspondingly small scales, roughly the Compton wavelength of the interacting particles. Recent theoretical work suggests that exploration of the gravitational force below a millimeter may help explain the hierarchy problem (gravity's weakness compared to the other forces) or put tighter constraints on supersymmetric models. It has been suggested that the discovery of non-Newtonian behavior is possible at length scales in the range of a micron to a millimeter.
520
$a
In this thesis, the construction of an apparatus for the study of mass-dependent gravity-like forces at length scales below 100 microns is described, and the first data collected with this device are discussed. A silicon microcantilever was utilized as the force sensor in a miniaturized Cavendish-style experiment. Cantilevers of this sort have been recently employed to measure forces in the attoNewton regime, and their small size enables measurement of forces in very small experimental geometries. A metallized silicon nitride membrane was suspended between the attracting masses to minimize electrostatic background forces. This experiment is the first study of gravity-like forces in which the sizes of the masses, force sensor, and mass separation are all less than 1 millimeter; separation between the mass surfaces of 25 microns was attained. These measurements have produced the most stringent constraints on non-Newtonian physics in the range of tens of microns. Theories in which supersymmetry is broken at low energy scales are severely constrained by the almost total elimination of the scalar moduli from consideration.
590
$a
School code: 0212.
650
4
$a
Physics, General.
$3
1018488
690
$a
0605
710
2 0
$a
Stanford University.
$3
754827
773
0
$t
Dissertation Abstracts International
$g
64-03B.
790
1 0
$a
Kapitulnik, Aharon,
$e
advisor
790
$a
0212
791
$a
Ph.D.
792
$a
2003
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3085267
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9187905
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login