語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Hand tracking analysis for telerobot...
~
Golenberg, Lavie P.
FindBook
Google Book
Amazon
博客來
Hand tracking analysis for telerobotic surgery.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Hand tracking analysis for telerobotic surgery./
作者:
Golenberg, Lavie P.
面頁冊數:
57 p.
附註:
Source: Masters Abstracts International, Volume: 45-02, page: 1044.
Contained By:
Masters Abstracts International45-02.
標題:
Engineering, Biomedical. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1439718
ISBN:
9780542985928
Hand tracking analysis for telerobotic surgery.
Golenberg, Lavie P.
Hand tracking analysis for telerobotic surgery.
- 57 p.
Source: Masters Abstracts International, Volume: 45-02, page: 1044.
Thesis (M.S.)--Wayne State University, 2007.
Robotic microsurgery provides many advantages for surgical operations, including tremor filtration, an increase in dexterity, and smaller incisions. A key benefit of robotic microsurgery is the ability to scale one's motions to a ratio where a surgeon's movements are at the highest efficiency. Due to the impracticality of continually changing the motion scale throughout the duration of a surgery, most operations are performed with a static control gain (e.g. a human-to-robot movement ratio of 3.9:1). However, relying on one motion scale throughout a surgery does not fully utilize the scaling capabilities of the robot and leads to longer surgery times. This study examines the effects of master hand controller positions and robotic instrument locations on accuracy and task time with a surgical robot as a basis for future automatic motion scaling systems. Fourteen surgically naive participants were directed to perform a simple aimed movement task on a PDA. Both hand position and robot instrument location had a significant effect on participant accuracy and task time. Hand positions farther away from the center of a participant's comfortable working envelope led to a decrease in accuracy. Conversely, locations closest to the participant's body had the highest accuracy. Robot instrument locations closest to the fulcrum point produced the highest accuracy and lowest task times.
ISBN: 9780542985928Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Hand tracking analysis for telerobotic surgery.
LDR
:02261nmm 2200301 4500
001
1834640
005
20071127115000.5
008
130610s2007 eng d
020
$a
9780542985928
035
$a
(UMI)AAI1439718
035
$a
AAI1439718
040
$a
UMI
$c
UMI
100
1
$a
Golenberg, Lavie P.
$3
1923280
245
1 0
$a
Hand tracking analysis for telerobotic surgery.
300
$a
57 p.
500
$a
Source: Masters Abstracts International, Volume: 45-02, page: 1044.
500
$a
Adviser: Darin Ellis.
502
$a
Thesis (M.S.)--Wayne State University, 2007.
520
$a
Robotic microsurgery provides many advantages for surgical operations, including tremor filtration, an increase in dexterity, and smaller incisions. A key benefit of robotic microsurgery is the ability to scale one's motions to a ratio where a surgeon's movements are at the highest efficiency. Due to the impracticality of continually changing the motion scale throughout the duration of a surgery, most operations are performed with a static control gain (e.g. a human-to-robot movement ratio of 3.9:1). However, relying on one motion scale throughout a surgery does not fully utilize the scaling capabilities of the robot and leads to longer surgery times. This study examines the effects of master hand controller positions and robotic instrument locations on accuracy and task time with a surgical robot as a basis for future automatic motion scaling systems. Fourteen surgically naive participants were directed to perform a simple aimed movement task on a PDA. Both hand position and robot instrument location had a significant effect on participant accuracy and task time. Hand positions farther away from the center of a participant's comfortable working envelope led to a decrease in accuracy. Conversely, locations closest to the participant's body had the highest accuracy. Robot instrument locations closest to the fulcrum point produced the highest accuracy and lowest task times.
590
$a
School code: 0254.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Engineering, Mechanical.
$3
783786
650
4
$a
Health Sciences, Medicine and Surgery.
$3
1017756
650
4
$a
Engineering, Robotics.
$3
1018454
690
$a
0541
690
$a
0548
690
$a
0564
690
$a
0771
710
2 0
$a
Wayne State University.
$3
975058
773
0
$t
Masters Abstracts International
$g
45-02.
790
1 0
$a
Ellis, Darin,
$e
advisor
790
$a
0254
791
$a
M.S.
792
$a
2007
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=1439718
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9225660
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入