語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Surface analysis for the permeation ...
~
Phalen, Robert Norman.
FindBook
Google Book
Amazon
博客來
Surface analysis for the permeation of captan through glove materials and on a gloved robotic hand.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Surface analysis for the permeation of captan through glove materials and on a gloved robotic hand./
作者:
Phalen, Robert Norman.
面頁冊數:
227 p.
附註:
Source: Dissertation Abstracts International, Volume: 67-09, Section: B, page: 4993.
Contained By:
Dissertation Abstracts International67-09B.
標題:
Health Sciences, Occupational Health and Safety. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3234362
ISBN:
9780542881886
Surface analysis for the permeation of captan through glove materials and on a gloved robotic hand.
Phalen, Robert Norman.
Surface analysis for the permeation of captan through glove materials and on a gloved robotic hand.
- 227 p.
Source: Dissertation Abstracts International, Volume: 67-09, Section: B, page: 4993.
Thesis (Ph.D.)--University of California, Los Angeles, 2006.
The aims of this research are to develop a new direct-reading method involving attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy and a novel whole-glove method to detect breakthrough and permeation of a pesticide, captan, through glove materials. The results are compared with permeation testing conducted using the American Society for Testing and Materials (ASTM) Method F 739-99a for an aqueous challenge concentration of 217 mg/mL Captan 50-WP and hexane collection solvent. Concurrent analyses using gas chromatography-mass spectrometry are performed for all permeation and surface sampling experiments. A solvent casting method is developed to produce uniform Captan surface films on a disposable nitrile glove for quantification with a portable ATR-FTIR spectrometer at 1735 +/- 5 cm-1. The quantifiable limits are 0.31 - 20.7 mug/cm2 ( r=0.9967; p≤0.05) for the outer glove surface, and 0.55 - 17.5 mug/cm 2 (r=0.9409; p≤0.05) for the inner surface. Relative humidity and temperature did not affect the uncoated gloves at this wavelength. Glove screening using ATR-FTIR is necessary to control for between-glove variation. ATR-FTIR is also used to measure the acrylonitrile (ACN) content of disposable nitrile gloves. A moving robotic hand test system is developed to investigate chemical permeation for a whole-glove system. Hand movement did not significantly affect the permeation of captan through nitrile gloves, but did influence the degradation of glove materials, resulting in penetration and catastrophic glove failures. The 8 h permeation results are 36.8 +/- 27.9 mug/cm 2 for the ASTM F 739-99a method with collection solvent, 0.8 +/- 0.3 mug/cm2 using ATR-FTIR with an ASTM F 739-99a test without collection solvent, and about 0.01 to 0.02 mug/cm2 for the whole-glove permeation tests without movement. The collection solvent played a significant role in eliciting increased permeation. Overall, ATR-FTIR can be used in glove surface exposure assessments and to evaluate the effectiveness of personal protective clothing in the field. The robotic hand simulated normal hand motions, is reliable, and could be used to assess the influence of hand movement on the permeation of non-volatile components through gloves. The whole-glove sampling methods developed in this study can be applied to field studies.
ISBN: 9780542881886Subjects--Topical Terms:
1017799
Health Sciences, Occupational Health and Safety.
Surface analysis for the permeation of captan through glove materials and on a gloved robotic hand.
LDR
:03291nmm 2200277 4500
001
1829091
005
20071106080124.5
008
130610s2006 eng d
020
$a
9780542881886
035
$a
(UMI)AAI3234362
035
$a
AAI3234362
040
$a
UMI
$c
UMI
100
1
$a
Phalen, Robert Norman.
$3
1917961
245
1 0
$a
Surface analysis for the permeation of captan through glove materials and on a gloved robotic hand.
300
$a
227 p.
500
$a
Source: Dissertation Abstracts International, Volume: 67-09, Section: B, page: 4993.
500
$a
Adviser: Shane S. Que Hee.
502
$a
Thesis (Ph.D.)--University of California, Los Angeles, 2006.
520
$a
The aims of this research are to develop a new direct-reading method involving attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy and a novel whole-glove method to detect breakthrough and permeation of a pesticide, captan, through glove materials. The results are compared with permeation testing conducted using the American Society for Testing and Materials (ASTM) Method F 739-99a for an aqueous challenge concentration of 217 mg/mL Captan 50-WP and hexane collection solvent. Concurrent analyses using gas chromatography-mass spectrometry are performed for all permeation and surface sampling experiments. A solvent casting method is developed to produce uniform Captan surface films on a disposable nitrile glove for quantification with a portable ATR-FTIR spectrometer at 1735 +/- 5 cm-1. The quantifiable limits are 0.31 - 20.7 mug/cm2 ( r=0.9967; p≤0.05) for the outer glove surface, and 0.55 - 17.5 mug/cm 2 (r=0.9409; p≤0.05) for the inner surface. Relative humidity and temperature did not affect the uncoated gloves at this wavelength. Glove screening using ATR-FTIR is necessary to control for between-glove variation. ATR-FTIR is also used to measure the acrylonitrile (ACN) content of disposable nitrile gloves. A moving robotic hand test system is developed to investigate chemical permeation for a whole-glove system. Hand movement did not significantly affect the permeation of captan through nitrile gloves, but did influence the degradation of glove materials, resulting in penetration and catastrophic glove failures. The 8 h permeation results are 36.8 +/- 27.9 mug/cm 2 for the ASTM F 739-99a method with collection solvent, 0.8 +/- 0.3 mug/cm2 using ATR-FTIR with an ASTM F 739-99a test without collection solvent, and about 0.01 to 0.02 mug/cm2 for the whole-glove permeation tests without movement. The collection solvent played a significant role in eliciting increased permeation. Overall, ATR-FTIR can be used in glove surface exposure assessments and to evaluate the effectiveness of personal protective clothing in the field. The robotic hand simulated normal hand motions, is reliable, and could be used to assess the influence of hand movement on the permeation of non-volatile components through gloves. The whole-glove sampling methods developed in this study can be applied to field studies.
590
$a
School code: 0031.
650
4
$a
Health Sciences, Occupational Health and Safety.
$3
1017799
650
4
$a
Health Sciences, Public Health.
$3
1017659
690
$a
0354
690
$a
0573
710
2 0
$a
University of California, Los Angeles.
$3
626622
773
0
$t
Dissertation Abstracts International
$g
67-09B.
790
1 0
$a
Hee, Shane S. Que,
$e
advisor
790
$a
0031
791
$a
Ph.D.
792
$a
2006
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3234362
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9219954
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼