Investigations in x-ray computed tomography polyacrylamide gel dosimetry.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Investigations in x-ray computed tomography polyacrylamide gel dosimetry./
作者:
Hilts, Michelle Louise.
面頁冊數:
208 p.
附註:
Source: Dissertation Abstracts International, Volume: 66-12, Section: B, page: 6705.
Contained By:
Dissertation Abstracts International66-12B.
標題:
Physics, Radiation. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR10402
ISBN:
9780494104026
Investigations in x-ray computed tomography polyacrylamide gel dosimetry.
Hilts, Michelle Louise.
Investigations in x-ray computed tomography polyacrylamide gel dosimetry.
- 208 p.
Source: Dissertation Abstracts International, Volume: 66-12, Section: B, page: 6705.
Thesis (Ph.D.)--The University of British Columbia (Canada), 2005.
Polyacrylamide gels (PAGs) are radiosensitive materials currently under development for use as three dimensional (3D) dosimeters in radiation therapy. Dose information is recorded in the gels and extracted through imaging. X-ray computed tomography (CT) has emerged as a promising gel imaging method due to a change in gel density that occurs upon irradiation. The accessibility of CT technology to cancer hospitals makes CT read-out clinically attractive, however the technique remains of limited clinical use due in part to poor dose resolution. This thesis investigates the use of CT for extracting dose information from PAG with an overall goal to improve achievable dose resolution. Thesis results are divided into three studies: a gel compositional study, a study of noise and dose resolution and a digital filtering study.
ISBN: 9780494104026Subjects--Topical Terms:
1019212
Physics, Radiation.
Investigations in x-ray computed tomography polyacrylamide gel dosimetry.
LDR
:04439nmm 2200289 4500
001
1827336
005
20061222092051.5
008
130610s2005 eng d
020
$a
9780494104026
035
$a
(UnM)AAINR10402
035
$a
AAINR10402
040
$a
UnM
$c
UnM
100
1
$a
Hilts, Michelle Louise.
$3
1916268
245
1 0
$a
Investigations in x-ray computed tomography polyacrylamide gel dosimetry.
300
$a
208 p.
500
$a
Source: Dissertation Abstracts International, Volume: 66-12, Section: B, page: 6705.
502
$a
Thesis (Ph.D.)--The University of British Columbia (Canada), 2005.
520
$a
Polyacrylamide gels (PAGs) are radiosensitive materials currently under development for use as three dimensional (3D) dosimeters in radiation therapy. Dose information is recorded in the gels and extracted through imaging. X-ray computed tomography (CT) has emerged as a promising gel imaging method due to a change in gel density that occurs upon irradiation. The accessibility of CT technology to cancer hospitals makes CT read-out clinically attractive, however the technique remains of limited clinical use due in part to poor dose resolution. This thesis investigates the use of CT for extracting dose information from PAG with an overall goal to improve achievable dose resolution. Thesis results are divided into three studies: a gel compositional study, a study of noise and dose resolution and a digital filtering study.
520
$a
The first study investigates the effects of gel composition on PAG CT dose response and the underlying density change. Systems for irradiating and imaging gels are designed and tested and dose response reproducibility is established. Results indicate dramatic variation in CT dose response sensitivity and range with gel composition. A model is developed to describe gel density change with dose, revealing two fundamental properties of the density to dose response: the density change that occurs per unit polymer yield is highest for gels with low and high concentrations of crosslinking molecule (%C) and the dose response sensitivity is linearly dependent on the total concentration of monomer in the gel.
520
$a
The second study investigates strategies for minimizing noise in x-ray CT polymer gel dosimetry and assesses system performance. Specifically, the effects of phantom design, scanning technique and image voxel size on image noise are investigated. This work leads to the establishment of a method of predicting image noise for any given CT imaging protocol. Image uniformity is also assessed, in the context of noise levels in gel dosimetry. The effect of scanning protocol on imaging time is established and the dose resolution achievable with an optimized system is calculated given voxel size and imaging time constraints. These results, when compared with published values for MRI and optical CT gel dosimetry indicate that CT dose resolution (e.g. 5%, 1 x 1 x 3 mm3 voxels), is still not at the level of the best MRI or optical CT techniques, however fast imaging times makes the rapid acquisition of volumetric data most feasible with x-ray CT.
520
$a
The third study investigates the potential of image filtering for improved dose resolution in CT gel dosimetry. CT image noise is characterized as Gaussian distributed and independent of signal strength and filters for reducing spatially invariant noise are investigated: mean, median, midpoint, adaptive mean, alpha-trimmed mean, sigma mean and a relatively new filter called SUSAN. The filters are tested on a CT image of a PAG irradiated with a clinically relevant dose distribution. Filter performance varies greatly in both achieved dose resolution and affects on the spatial distribution of dose. The ADAPTIVE and SUSAN filters provide the best overall performance, more than halving the dose resolution without significantly distorting the spatial distribution of dose.
520
$a
In summary, this thesis provides new insight into the fundamental nature of PAG density to dose response, develops strategies for minimizing image noise and quantifies system performance and demonstrates that digital image filtering is an effective tool to provide additional improvements to dose resolution.
590
$a
School code: 2500.
650
4
$a
Physics, Radiation.
$3
1019212
690
$a
0756
710
2 0
$a
The University of British Columbia (Canada).
$3
626643
773
0
$t
Dissertation Abstracts International
$g
66-12B.
790
$a
2500
791
$a
Ph.D.
792
$a
2005
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=NR10402
筆 0 讀者評論
館藏地:
全部
電子資源
出版年:
卷號:
館藏
1 筆 • 頁數 1 •
1
條碼號
典藏地名稱
館藏流通類別
資料類型
索書號
使用類型
借閱狀態
預約狀態
備註欄
附件
W9218199
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
在架
0
1 筆 • 頁數 1 •
1
多媒體
評論
新增評論
分享你的心得
Export
取書館
處理中
...
變更密碼
登入