Language:
English
繁體中文
Help
回圖書館首頁
手機版館藏查詢
Login
Back
Switch To:
Labeled
|
MARC Mode
|
ISBD
Three-dimensional computational mode...
~
Lemmon, Jack David, Jr.
Linked to FindBook
Google Book
Amazon
博客來
Three-dimensional computational modeling of fluid-structure interaction: Study of diastolic function in a thin-walled left heart model.
Record Type:
Electronic resources : Monograph/item
Title/Author:
Three-dimensional computational modeling of fluid-structure interaction: Study of diastolic function in a thin-walled left heart model./
Author:
Lemmon, Jack David, Jr.
Description:
238 p.
Notes:
Source: Dissertation Abstracts International, Volume: 59-06, Section: B, page: 2885.
Contained By:
Dissertation Abstracts International59-06B.
Subject:
Engineering, Biomedical. -
Online resource:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9837771
ISBN:
9780591914368
Three-dimensional computational modeling of fluid-structure interaction: Study of diastolic function in a thin-walled left heart model.
Lemmon, Jack David, Jr.
Three-dimensional computational modeling of fluid-structure interaction: Study of diastolic function in a thin-walled left heart model.
- 238 p.
Source: Dissertation Abstracts International, Volume: 59-06, Section: B, page: 2885.
Thesis (Ph.D.)--Georgia Institute of Technology, 1998.
Aided by advancements in computer speed and modeling techniques, computational modeling of cardiac function has continued to develop over the past twenty years. These models have grown from static two-dimensional models that looked at either the associated fluid or solid mechanics to simulations that incorporate elaborate three-dimensional geometries with moving boundaries. The goal of the current study was to develop a computational method that provides blood-tissue interaction under physiologic Reynolds numbers, and then apply it to thin-walled models of cardiac chambers. To accomplish this goal, the Immersed Boundary Method was used to provide the interaction of the tissue and blood in response to fluid forces and changes in tissue pathophysiology. The fluid mass and momentum conservation equations were solved by Patankar's Semi-Implicit Method for Pressure Linked Equations (SIMPLE) to provide solution stability at physiologic Reynolds numbers. Initially, these methods were applied to a thin-walled, truncated ellipsoid model that contracted over a 100 msec period to test the feasibility of combining them to achieve physiologic Reynolds numbers. The methods were then applied to a left heart model of diastolic function consisting of the left ventricle, left atrium, and pulmonary flow. The input functions for this model consisted of the pulmonary driving pressure and time-dependent relationship for changes in tissue properties during the simulation. The results obtained from the left heart model were compared to clinically observed diastolic flow conditions for validation. The model was first applied to normal diastolic function. Then, cases involving delayed ventricular relaxation, increased ventricular stiffness, increased atrial contraction, and atrial fibrillation were compared to the normal case to illustrate the effect of these diseases on the flow fields.
ISBN: 9780591914368Subjects--Topical Terms:
1017684
Engineering, Biomedical.
Three-dimensional computational modeling of fluid-structure interaction: Study of diastolic function in a thin-walled left heart model.
LDR
:02857nmm 2200277 4500
001
1824721
005
20061206120119.5
008
130610s1998 eng d
020
$a
9780591914368
035
$a
(UnM)AAI9837771
035
$a
AAI9837771
040
$a
UnM
$c
UnM
100
1
$a
Lemmon, Jack David, Jr.
$3
1913778
245
1 0
$a
Three-dimensional computational modeling of fluid-structure interaction: Study of diastolic function in a thin-walled left heart model.
300
$a
238 p.
500
$a
Source: Dissertation Abstracts International, Volume: 59-06, Section: B, page: 2885.
500
$a
Director: Ajit P. Yoganathan.
502
$a
Thesis (Ph.D.)--Georgia Institute of Technology, 1998.
520
$a
Aided by advancements in computer speed and modeling techniques, computational modeling of cardiac function has continued to develop over the past twenty years. These models have grown from static two-dimensional models that looked at either the associated fluid or solid mechanics to simulations that incorporate elaborate three-dimensional geometries with moving boundaries. The goal of the current study was to develop a computational method that provides blood-tissue interaction under physiologic Reynolds numbers, and then apply it to thin-walled models of cardiac chambers. To accomplish this goal, the Immersed Boundary Method was used to provide the interaction of the tissue and blood in response to fluid forces and changes in tissue pathophysiology. The fluid mass and momentum conservation equations were solved by Patankar's Semi-Implicit Method for Pressure Linked Equations (SIMPLE) to provide solution stability at physiologic Reynolds numbers. Initially, these methods were applied to a thin-walled, truncated ellipsoid model that contracted over a 100 msec period to test the feasibility of combining them to achieve physiologic Reynolds numbers. The methods were then applied to a left heart model of diastolic function consisting of the left ventricle, left atrium, and pulmonary flow. The input functions for this model consisted of the pulmonary driving pressure and time-dependent relationship for changes in tissue properties during the simulation. The results obtained from the left heart model were compared to clinically observed diastolic flow conditions for validation. The model was first applied to normal diastolic function. Then, cases involving delayed ventricular relaxation, increased ventricular stiffness, increased atrial contraction, and atrial fibrillation were compared to the normal case to illustrate the effect of these diseases on the flow fields.
590
$a
School code: 0078.
650
4
$a
Engineering, Biomedical.
$3
1017684
650
4
$a
Biology, Animal Physiology.
$3
1017835
690
$a
0541
690
$a
0433
710
2 0
$a
Georgia Institute of Technology.
$3
696730
773
0
$t
Dissertation Abstracts International
$g
59-06B.
790
1 0
$a
Yoganathan, Ajit P.,
$e
advisor
790
$a
0078
791
$a
Ph.D.
792
$a
1998
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=9837771
based on 0 review(s)
Location:
ALL
電子資源
Year:
Volume Number:
Items
1 records • Pages 1 •
1
Inventory Number
Location Name
Item Class
Material type
Call number
Usage Class
Loan Status
No. of reservations
Opac note
Attachments
W9215584
電子資源
11.線上閱覽_V
電子書
EB
一般使用(Normal)
On shelf
0
1 records • Pages 1 •
1
Multimedia
Reviews
Add a review
and share your thoughts with other readers
Export
pickup library
Processing
...
Change password
Login