語系:
繁體中文
English
說明(常見問題)
回圖書館首頁
手機版館藏查詢
登入
回首頁
切換:
標籤
|
MARC模式
|
ISBD
Reliability and validity of electrog...
~
Bronner, Shaw.
FindBook
Google Book
Amazon
博客來
Reliability and validity of electrogoniometry measurement of lower extremity dance movement.
紀錄類型:
書目-電子資源 : Monograph/item
正題名/作者:
Reliability and validity of electrogoniometry measurement of lower extremity dance movement./
作者:
Bronner, Shaw.
面頁冊數:
318 p.
附註:
Source: Dissertation Abstracts International, Volume: 66-12, Section: B, page: 6536.
Contained By:
Dissertation Abstracts International66-12B.
標題:
Health Sciences, Occupational Health and Safety. -
電子資源:
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3201057
ISBN:
9780542462580
Reliability and validity of electrogoniometry measurement of lower extremity dance movement.
Bronner, Shaw.
Reliability and validity of electrogoniometry measurement of lower extremity dance movement.
- 318 p.
Source: Dissertation Abstracts International, Volume: 66-12, Section: B, page: 6536.
Thesis (Ph.D.)--University of Medicine and Dentistry of New Jersey, 2006.
Goals. Exposure risk factors (repetitive motions, high forces and velocities, awkward postures) have been identified for work-related musculoskeletal disorders (WMSD) of the neck, upper extremity, and back. However, little research has been conducted to identify lower extremity WMSD risk factors. Dancers represent an occupational group with a high incidence of lower extremity WMSD. This investigation establishes the accuracy, reliability, and concurrent validity of electrogoniometers(s) for measuring occupational lower extremity exposure among dancers.
ISBN: 9780542462580Subjects--Topical Terms:
1017799
Health Sciences, Occupational Health and Safety.
Reliability and validity of electrogoniometry measurement of lower extremity dance movement.
LDR
:03382nmm 2200313 4500
001
1824253
005
20061128083245.5
008
130610s2006 eng d
020
$a
9780542462580
035
$a
(UnM)AAI3201057
035
$a
AAI3201057
040
$a
UnM
$c
UnM
100
1
$a
Bronner, Shaw.
$3
1913337
245
1 0
$a
Reliability and validity of electrogoniometry measurement of lower extremity dance movement.
300
$a
318 p.
500
$a
Source: Dissertation Abstracts International, Volume: 66-12, Section: B, page: 6536.
500
$a
Chair: Ellen Ross.
502
$a
Thesis (Ph.D.)--University of Medicine and Dentistry of New Jersey, 2006.
520
$a
Goals. Exposure risk factors (repetitive motions, high forces and velocities, awkward postures) have been identified for work-related musculoskeletal disorders (WMSD) of the neck, upper extremity, and back. However, little research has been conducted to identify lower extremity WMSD risk factors. Dancers represent an occupational group with a high incidence of lower extremity WMSD. This investigation establishes the accuracy, reliability, and concurrent validity of electrogoniometers(s) for measuring occupational lower extremity exposure among dancers.
520
$a
Method. This project employed two separate experiments. Investigation I determined the accuracy of electrogoniometry measurement compared to a digital protractor. Correction equations were determined to diminish measurement error. Investigation II compared electrogoniometry to a criterion measure, motion analysis, in 10 dance movements in a sample of 17 dancers. Intraclass correlation coefficients (ICC) and standard error of measurement (SEM) were calculated for hip, knee, and ankle angular displacements. Correction equations were applied to the data to ascertain whether SEM and ICC results improved.
520
$a
Results. In Investigation I, correlations of the electrogoniometers to the digital protractor were very high (r ≥ 0.998, SEM ≤ 3.65°). Application of a 6th order polynomial equation resulted in improved 'fit' (r ≥ 0.999, SEM ≤ 2.55°). In Investigation II, instrument and intra-rater reliability correlations were very high (r ≥ 0.946 and r ≥ 0.947, SEM ≤5.93° and ≤5.42°). The electrogoniometers demonstrated acceptable concurrent validity correlations (r ≥ 0.799) to motion analysis with one exception (grand battement arabesque hip r ≥ 0.616). This exception may be due to sensor crosstalk. SEM for all sensors were ≤ 9.73°. The correction equations did not consistently improve the SEM and ICC results.
520
$a
Implication. Compared to other types of motion measurement, this error is acceptable for workplace studies of dancers. Peak amplitudes revealed that common dance angular displacements exceed those typically found in activities of daily living, substantiating that dance functional movements require work at joint motion extremes. Validating this instrumentation facilitates future studies to characterize dance exposure and identify risk factors that contribute to lower extremity WMSD.
590
$a
School code: 0301.
650
4
$a
Health Sciences, Occupational Health and Safety.
$3
1017799
650
4
$a
Health Sciences, Rehabilitation and Therapy.
$3
1017926
690
$a
0354
690
$a
0382
710
2 0
$a
University of Medicine and Dentistry of New Jersey.
$3
1026090
773
0
$t
Dissertation Abstracts International
$g
66-12B.
790
1 0
$a
Ross, Ellen,
$e
advisor
790
$a
0301
791
$a
Ph.D.
792
$a
2006
856
4 0
$u
http://pqdd.sinica.edu.tw/twdaoapp/servlet/advanced?query=3201057